Problem No.1: Sensitivity: LNT Construction Internal Use

The document provides yearly maximum rainfall data from 1987-2016 for one catchment and 1995-2016 for another. It also provides details on the catchment characteristics. The problems ask to compute the 2yr, 5yr, 10yr, 20yr, 50yr and 100yr return period floods for each catchment using the rational method. Additionally, maximum flood discharge data from 1951-1980 and 1973-2012 are given for two other catchments/rivers and the problems ask to estimate the 50yr, 100yr and 150yr floods.

Uploaded by

sirkali1973
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
56 views

Problem No.1: Sensitivity: LNT Construction Internal Use

The document provides yearly maximum rainfall data from 1987-2016 for one catchment and 1995-2016 for another. It also provides details on the catchment characteristics. The problems ask to compute the 2yr, 5yr, 10yr, 20yr, 50yr and 100yr return period floods for each catchment using the rational method. Additionally, maximum flood discharge data from 1951-1980 and 1973-2012 are given for two other catchments/rivers and the problems ask to estimate the 50yr, 100yr and 150yr floods.

Uploaded by

sirkali1973
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 9

PROBLEM No.

1
The yearly maximum one day rainfall data from the year 1987 to 2016 are given below
Rainfall in
Year mm
1987 108
1988 196.4
1989 177
1990 181
1991 251
1992 108
1993 192.4
1994 350.2
1995 374
1996 346
1997 136
1998 142
1999 110
2000 62
2001 108
2002 93
2003 102
2004 71
2005 255
2006 97
2007 176
2008 236
2009 151
2010 93
2011 99
2012 93
2013 146
2014 95
2015 475
2016 214

Compute 2Yr,5Yr,10Yr,20Yr, 50Yr and 100Yr return period flood for the given catchment data.Ad

# Sensitivity: LNT Construction Internal Use


Catchment 1
Catchment Area 911 Ha
Slope of catchment 0.0011567
Spread factor 0.87
Coefficient of runoff 0.7
Maximum length of travel 6916 m

Catchment 2
Catchment Area 1516 Ha
Slope of catchment 0.0020621
Spread factor 0.98
Coefficient of runoff 0.7
Maximum length of travel 7759 m

PROBLEM No.2
The yearly maximum one day rainfall data from the year 1995 to 2016 are given below
Rainfall in
Year mm
1995 148.2
1996 282.2
1997 180.2
1998 107
1999 90.4
2000 106.2
2001 170
2002 200.1
2003 77.9
2004 66.2
2005 282.8
2006 148
2007 143.5
2008 279.2
2009 132.5

# Sensitivity: LNT Construction Internal Use


2010 104.4
2011 97.6
2012 80.9
2013 123.9
2014 115.3
2015 354.1
2016 202.5

Compute 2Yr,5Yr,10Yr,20Yr, 50Yr and 100Yr return period flood for the given catchment data. A
Catchment 1
Catchment Area 1409.5 Ha
Slope of catchment 0.0006840
Spread factor 0.91
Coefficient of runoff 0.9
Maximum length of travel 7310.04 m

Catchment 2
Catchment Area 1034.4 Ha
Slope of catchment 0.0030075
Spread factor 0.92
Coefficient of runoff 0.8
Maximum length of travel 5985.12 m

PROBLEM No.3
Yearly recorded maximum flood in a river for the period from 1951 to 1980 are given below
Estimate the flood discharge for return periods of 50, 100, and 150 years

Max. flood Max. flood


discharge in discharge in
Year Cumecs Year Cumecs
1951 2947 1968 3320
1952 3521 1969 6599
1953 2399 1970 3700
1954 4124 1971 4175
1955 3496 1972 2988

# Sensitivity: LNT Construction Internal Use


1956 2947 1973 2709
1957 5060 1974 3873
1958 4903 1975 4593
1959 3757 1976 6761
1960 4798 1977 1971
1961 4290 1978 2300
1962 4652 1979 1980
1963 5050 1980 2100
1964 6900
1965 4366
1966 3380
1967 7826

PROBLEM No.4
Yearly recorded maximum flood in a river for the period from 1973 to 2012 are given below
Estimate the flood discharge for return periods of 50, 100, and 150 years
Max. flood Max. flood
discharge in discharge in
Year Cumecs Year Cumecs
1973 390 1990 195
1974 140 1991 389
1975 301 1992 220
1976 173 1993 149
1977 226 1994 248
1978 591 1995 371
1979 386 1996 503
1980 154 1997 312
1981 166 1998 1731
1982 122 1999 670
1983 143 2000 230
1984 189 2001 477
1985 172 2002 580
1986 114 2003 246
1987 125 2004 760
1988 113 2005 877

# Sensitivity: LNT Construction Internal Use


1989 139 2006 1013
2007 215
2008 680
2009 355
2010 1410
2011 943
2012 426

# Sensitivity: LNT Construction Internal Use


catchment data.Adopt rational method.

# Sensitivity: LNT Construction Internal Use


766

# Sensitivity: LNT Construction Internal Use


catchment data. Adopt rational method.

given below

# Sensitivity: LNT Construction Internal Use


given below

# Sensitivity: LNT Construction Internal Use

You might also like