5SDD 71x0400-Datasheet

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

5SDD 71X0400

 5SDD 71X0400


Old part no. DS 808X-7110-04
Welding diode
Properties Key parameters
 High forward current capability V RRM = 400 V
 Low forward and reverse recovery losses I FAVm = 7 110 A
 High operational reliability I FSM = 55 000 A
V TO = 0.740 V
Applications rT = 0.026 m
 Welding equipment
 High current application up to 2000 Hz

Types
type VRRM
5SDD 71X0400 400 V
Conditions: Tj = -40 ÷ 170 °C,
half sine waveform,
f = 50 Hz

Mechanical data
Fm Mounting force 22 ± 2 kN
m Weight 0.14 kg
DS Surface creepage 4 mm
distance
Da Air strike distance 4 mm

Fig. 1 Case


ABB s.r.o.
Novodvorska 1768/138a, 142 21 Praha 4, Czech Republic
tel.: +420 261 306 250, http://www.abb.com/semiconductors

TS - DS/120/04c Mar-19 1 of 6
5SDD 71X0400

Maximum Ratings Maximum Limits Unit


VRRM Repetitive peak reverse voltage 400 V
Tj = -40 ÷ 170 °C
IFAVm Average forward current 7 110 A
Tc = 85°C
IFRMS RMS forward current 11 200 A
Tc = 85°C
IR Repetitive reverse current 50 mA
VR = VRRM
IFSM Nonrepetitive peak surge current 55 000 A
tp = 10 ms, VR = 0 V, half sine pulse
I2t Limiting load integral 15 125 000 A2s
tp = 10 ms, VR = 0 V, half sine pulse
Tjmin –Tjmax Operating temperature range - 40 ÷ 170 °C
Tstgmin - Storage temperature range - 40 ÷ 170 °C
Tstgmax
Unless otherwise specified Tj = 170 °C

Characteristics Value Unit


min typ max
VT0 Threshold voltage 0.740 V
rT Forward slope resistance 0.026 m
IF1 = 5 000 A, IF2 = 15 000 A
VFM Maximum forward IFM = 5 000 A, Tj = 25 °C 0.95 1.00 V
voltage
IFM = 5 000 A 0.87
Qrr Recovered charge 300 C
IFM = 1000 A, di/dt = -30 A/s, VR = 50 V
Unless otherwise specified Tj = 170 °C

Thermal Specifications Value Unit


Rthjc Thermal resistance junction double side cooling 10 K/kW
to case
single side cooling 20 K/kW
Rthch Thermal resistance case to double side cooling 5 K/kW
heatsink
single side cooling 10 K/kW

ABB s.r.o., Novodvorska 1768/138a, 142 21 Praha 4, Czech Republic

ABB s.r.o. reserves the right to change the data contained herein at any time without notice
TS - DS/120/04c Mar-19 2 of 6
5SDD 71X0400

Analytical function for transient i 1 2 3 4


thermal impedance Ri( K/kW ) 8.7977 0.6405 0.4702 0.0994
i ( s ) 0.1052 0.017 0.0042 0.0002
4
Z thjc   Ri (1  exp(t / i )) 12

Transient thermal impedance junction


i 1 10

to case Zthjc ( K/kW )


Fm = 22 ± 2 kN, Double side cooled
6

0
0.0001 0.001 0.01 0.1 1

Square wave pulse duration td ( s )

Fig. 2 Dependence transient thermal impedance junction


to case on square pulse

20000 100 25
IF ( A )

 i2dt (106 A2s)


IFSM
IFSM ( kA )

Tj = 170 C
18000
i2dt
16000
80 20
14000

12000

10000
60 15

8000

6000

4000 40 10

2000

0
0 0.5 1 1.5 20 5
VF ( V ) 1 10 100
t ( ms )

Fig. 3 Maximum forward voltage drop Fig. 4 Surge forward current vs. pulse length,
characteristics half sine wave, single pulse,
VR = 0 V, Tj = Tjmax

ABB s.r.o., Novodvorska 1768/138a, 142 21 Praha 4, Czech Republic

ABB s.r.o. reserves the right to change the data contained herein at any time without notice
TS - DS/120/04c Mar-19 3 of 6
5SDD 71X0400

PT ( W ) 10000 y = 60° 120° 180° 10000 y = 30° 60° 90° 120°

PT ( W )
180°
9000 9000

8000 DC 8000 270°


DC
7000 7000

6000 6000

5000 5000

4000 4000

3000 3000

2000 2000

1000 1000

0 0
0 2000 4000 6000 8000 0 2000 4000 6000 8000
I FAV ( A ) I FAV ( A )

Fig. 5 Forward power loss vs. average forward Fig. 6 Forward power loss vs. average forward
current, sine waveform, f = 50 Hz current, square waveform, f = 50 Hz

180 180
TC ( °C )

170 170

160 160

150 150

140 140

130 130

120 120

110 110

100 100
DC DC
90 90
270°
80 80
180°
70 180° 70
y =60° 120° y = 30° 60° 90° 120°
60 60
0 2000 4000 6000 8000 0 2000 4000 6000 8000
I FAV ( A )

Fig. 7 Max. case temperature vs. aver. forward Fig. 8 Max.case temperature vs. aver. forward
current, sine waveform, f = 50 Hz current, square waveform, f = 50 Hz

ABB s.r.o., Novodvorska 1768/138a, 142 21 Praha 4, Czech Republic

ABB s.r.o. reserves the right to change the data contained herein at any time without notice
TS - DS/120/04c Mar-19 4 of 6
5SDD 71X0400

Fig. 9 Definition of ED for typical welding sequence Fig. 10 Definition of ID


for single-phase
centre tap

25 25
ID ( kA )
ID ( kA )

T1 = 20 ms

T1 = 20 ms

20 20

40 ms
40 ms

15 15

100 ms
100 ms
200 ms
10 10 200 ms
1000 ms / DC
1000 ms / DC

5 5
1 10 100 1 10 100
Duty cycle ED ( % ) Duty cycle ED ( % )

Fig. 11 Current load capacity, cont., Fig. 12 Current load capacity, cont.,
DC output welding current with single-phase DC output welding current with single-phase
centre tap vs. duty cycle centre tap vs. duty cycle
f = 1000 Hz, square wave, Tj = 80 °C f = 1000 Hz, square wave, Tj = 70 °C

ABB s.r.o., Novodvorska 1768/138a, 142 21 Praha 4, Czech Republic

ABB s.r.o. reserves the right to change the data contained herein at any time without notice
TS - DS/120/04c Mar-19 5 of 6
5SDD 71X0400

25 25

ID ( kA )
ID ( kA )

20 T1 = 20 ms 20

15 40 ms 15 T1 = 20 ms

100 ms 40 ms
10 10
200 ms
100 ms
1000 ms / DC
200 ms
5 5 1000 ms / DC
1 10 100 1 10 100
Duty cycle ED ( % ) Duty cycle ED ( % )

Fig. 13 Current load capacity, cont., Fig. 14 Current load capacity, cont.,
DC output welding current with single-phase DC output welding current with single-phase
centre tap vs. duty cycle centre tap vs. duty cycle
f = 1000 Hz, square wave, Tj = 60 °C f = 1000 Hz, square wave, Tj = 40 °C

Notes:

ABB s.r.o., Novodvorska 1768/138a, 142 21 Praha 4, Czech Republic

ABB s.r.o. reserves the right to change the data contained herein at any time without notice
TS - DS/120/04c Mar-19 6 of 6