200W True Sine Wave DC-AC Power Inverter: Series
200W True Sine Wave DC-AC Power Inverter: Series
E¡¡E¡½ Features :
True sine wave output (THD<3%)
E¡
equipment, vehicle and yacht ...etc.
3 years warranty
E13
SPECIFICATION
MODEL TS-200-112 ¡¼ TS-200-124 ¡¼ TS-200-148 ¡¼ TS-200-212 ¡¼ TS-200-224 ¡¼ TS-200-248 ¡¼
RATED POWER 200W
MAXIMUM OUTPUT POWER 230W for 180 sec. / 300W for 10 sec. / surge power 400W for 30 cycles(typ.)
Factory setting set at 110VAC Factory setting set at 230VAC
AC VOLTAGE
100 / 110 / 115 / 120VAC selectable by setting button S.W 200 / 220 / 230 / 240VAC selectable by setting button S.W
OUTPUT
FREQUENCY ¡Ó
60 0.1Hz 50/60Hz selectable by setting button ¡Ó
50 0.1Hz 50/60Hz selectable by setting button
WAVEFORM True sine wave (THD<3%) at rated input voltage
AC REGULATION Note.1 ¡Ó3.0% at rated input voltage
FRONT PANEL INDICATOR Operation status ; Green : normal, Orange(flashing) : remote control OFF, Red : abnormal
BAT. VOLTAGE 12V 24V 48V 12V 24V 48V
VOLTAGE RANGE (Typ.) Note.3 10.5 ~ 15VDC 21 ~ 30VDC 42 ~ 60VDC 10.5 ~ 15VDC 21 ~ 30VDC 42 ~ 60VDC
DC CURRENT (Typ.) 20A 10A 5A 20A 10A 5A
INPUT NO LOAD CURRENT DRAW (Typ.) 1.25A 0.63A 0.32A 1.25A 0.63A 0.62A
OFF MODE CURRENT DRAW ¡Ø1mA
EFFICIENCY (Typ.) Note.1 86% 87.5% 88% 86% 87.5% 88%
BATTERY TYPES Open & sealed Lead Acid
FUSE 30A*2 30A*1 15A*1 30A*2 30A*1 15A*1
BATTERY BAT. LOW ALARM ¡Ó
11.3 4% 22.5 4% ¡Ó Ó¡
45 4% ¡Ó
11.3 4% 22.5 4%¡Ó ¡Ó
45 4%
10.5¡Ó4% ¡Ó 42¡Ó4% 10.5¡Ó4% ¡Ó ¡Ó
INPUT
21 4% 21 4% 42 4%
PROTECTION BAT. LOW SHUTDOWN
BAT. POLARITY By internal fuse open
OVER TEMPERATURE
85 ¢J¡Ó 5¢J 80 ¢J¡Ó 5¢J 80 ¢J¡Ó 5¢J 85 ¢J¡Ó 5¢J 80 ¢J¡Ó 5¢J 80 ¢J¡Ó 5¢J
Protection type : Shut down o/p voltage, re-power on to recover; by internal RTH1 detect power transistor
OUTPUT OUTPUT SHORT Protection type : Shut down o/p voltage, re-power on to recover
PROTECTION 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec.
OVER LOAD (Typ.)
Protection type : Shut down o/p voltage, re-power on to recover
GFCI PROCTECTION Optional (Only type F) None
FUNCTION REMOTE CONTROL Open : Normal work ; Short : Remote off
WORKING TEMP. ¢ J
-10 ~ +35 @ 100% load ; +60 ¢J @ 50% load -10 ~ +40 ¢J @ 100% load, +60¢J @ 50% load
WORKING HUMIDITY 20% ~ 90% RH non-condensing
-30 ~ +70¢J / -22 ~ +158 F, 10 ~ 95% RH
ENVIRONMENT o
STORAGE TEMP., HUMIDITY
VIBRATION 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS Design refer to UL458 None
LVD None EN60950-1
SAFETY & WITHSTAND VOLTAGE Bat. I/P - AC O/P:3.0KVAC AC O/P - FG:1.5KVAC
EMC ISOLATION RESISTANCE Bat. I/P-AC O/P, AC O/P-FG:100M Ohms / 500VDC / 25 / 70% RH ¢J
EMC EMISSION Compliance to FCC class A Compliance to EN55022 class A, 72/ 245/ CEE, 95/ 54/ CE, E-Mark
EMC IMMUNITY None Compliance to EN61000-4-2,3,8
o
MTBF 106.2K hrs min. MIL-HDBK-217F (25 C)
OTHERS DIMENSION 205*158*59mm (L*W*H)
PACKING 1.63Kg; 6pcs/10.8Kg/1.44CUFT
¢J
NOTE 1.Efficiency & AC regulation is tested by 200W, linear load at 13V/26V/52V input voltage.
Receptacle type
80
R.C
Ground
Chassis 60
59
TS-200-1xx
50
LOAD (%)
_
_ _ OFF
40
Will Damage The Unit. ON
Reverse Polarity
20
11
8.9
-10 0 10 20 30 35 40 50 60 70
18
12
(HORIZONTAL)
ENVIRONMENT TEMPERATURE ( ) ¢J
42.5
9
7
AC OUTPUT Status
Setting
120
205
Type-A
Status
AC OUTPUT
Setting
Type-B
147
158