High Capacity Wire Crimp Test Fixture CW-5000N/CH-5000N
High Capacity Wire Crimp Test Fixture CW-5000N/CH-5000N
High Capacity Wire Crimp Test Fixture CW-5000N/CH-5000N
Testing Image
1 / 4
2019/08/29
IMADA CO., LTD.
High Capacity Wire Crimp Test Fixture CW-5000N/CH-5000N
Measuring Procedures
Tighten the fixing bolt of
Attach the terminal to the fixing
Fix the plate on the holder. CW-5000N to clamp the wire
plate of CH-5000N with the screw.
between the blocks.
Specifications
Model CH-5000N CW-5000N
Capacity 5000N
Clamping Method Screwing to fix on the plate Screwing to clamp with the blocks
Sample Diameter 4mm to 12mm (inner of ring terminal) Up to 30mm (wire)
Dimensions See [Dimensions]
Weight Approx. 315g *1 Approx. 2415g
Mounting Screw M10 -
*1 Weight of the attachment is also applied as a load on the force gauge. Consider it when selecting the capacity of a force
gauge.
* Some hard samples made of hardened material or samples with slippery surface are not suitable to clamp with this
product.
* Some special wires such as stranded wires may not be suitable to clamp with this product.
Example 1 Image
* Refer to the specification of each product for details.
* Product configuration varies depending on the shape and characteristic of the sample, and measurement conditions.
* The recommended capacity of force gauge varies depending on the expected force to be loaded.
*1 Optional cable activates force control function to apply certain force for a set period of time for conducting durability test.
2 / 4
2019/08/29
IMADA CO., LTD.
High Capacity Wire Crimp Test Fixture CW-5000N/CH-5000N
Related Products
Spare Fixing Plates Knurled Cam Grip Rotary Wire Terminal Fixture
CH5000-D10/CH-5000-D12 GP-30 FW-12/PW-4
Allows for efficient testing by Ideal for clamping wires and Designed for easy sample setting
preparing the next testing sample cables. by hooking through the slit or pin for
while conducting a test. crimp tests.
3 / 4
2019/08/29
IMADA CO., LTD.
High Capacity Wire Crimp Test Fixture CW-5000N/CH-5000N
[Dimensions]
CH-5000N
CW-5000N
Unit: mm
[Cautions]
- Information in this document is subject to change without prior notice.
- This document is product descriptions and handling precautions, and do not guarantee various
characteristics or safety.
- This product is designed for force measurement purpose only.
- Do not copy and use this content without authorization.
- A force gauge (sold separately) is required to use this product.
- Some samples may not be suitable to measure with this product.
4 / 4
2019/08/29