0% found this document useful (0 votes)
486 views3 pages

Sample of Corrosion Mapping Using Thickness Gauge Grid File

The document reports on the results of ultrasonic thickness measurements performed on various parts of power plant equipment, including a feed water inlet pipe to an economizer, a drain pipe, and a recirculation tee. Tables show the thickness measurements in millimeters taken at numerous locations around the circumference and along the length of the pipes and tee. No thickness measurements were found to be below the minimum required thickness.

Uploaded by

Bagus Hadiwibowo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
486 views3 pages

Sample of Corrosion Mapping Using Thickness Gauge Grid File

The document reports on the results of ultrasonic thickness measurements performed on various parts of power plant equipment, including a feed water inlet pipe to an economizer, a drain pipe, and a recirculation tee. Tables show the thickness measurements in millimeters taken at numerous locations around the circumference and along the length of the pipes and tee. No thickness measurements were found to be below the minimum required thickness.

Uploaded by

Bagus Hadiwibowo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

NON DESTRUCTIVE

SheetEXAMINATION
1 of 3 REPORT
2.6.5. Feed Water Inlet Pipe to Economiser
ULTRASONIC THICKNESS MEASUREMENT
Location : Equipment Brand : Panametric 38DL Plus
Operator : Rizky Ramadhan H Probe : DA 501 EN
Procedure No. : RBT - P - 14 Block Calibration : V1 / Range 100 mm
Measurement Result (mm)

Legend :
: Minimum Thickness Value
: Maximum Thickness Value

Sketch / Photograph
ULTRASONIC THICKNESS
Sheet 2 of 3 MEASUREMENT
Location Equipment Brand : DMS Go
Operator : Rizki R. Hasibuan Probe : DA 501 EN
Procedure No. : RBT - P - 14 Block Calibration : V1 / Range 25 mm
Thickness Measurement Result (mm)
PART NO./NAME LOCATION Remark
A B C D
1 79,84 79,49 79,54 79,6
2 79,18 78,94 79,86 78,81
3 78,09 78,32 77,51 77,15
4 78,73 78,37 76,95 77,31
5 77,72 77,65 77,71 77,98
6 79,5 79,73 - 78,8
7 80,48 80,08 80,47 77,99
8 79,39 80,19 79,78 79,92
9 80,39 80,39 80,45 80,27
10 88,25 77,94 80,35 77,26
11 77,26 77,2 78,12 76,16
12 77,88 78,29 77,48 78,13
Min. Thickness 77,26 77,20 76,95 76,16
Thickness Measurement Result (mm)
LOCATION
pipe line eco inlet E F G
1 80,1 81,03 82,12
2 78,98 79,89 80,64
3 77,88 78,27 70,13
4 77,71 78,63 78,28
5 78,15 78,09 77,24
6 78,28 - 79,33
7 81,2 80,32 81,46
8 77,48 79,63 80,39
9 77,92 79,96 80,79
10 77,88 78,43 78,36
11 77,97 76,87 76,75
12 77,36 - 78,26
Min. Thickness 77,48 76,87 70,13

Thickness Value (mm)


PART NO./NAME LOCATION Remark
0 (North) 90 (East) 180 (South) 270 (West) Min. Thickness
A 12,91 13,41 13,36 13,20 12,91
Drain Pipe
B 14,16 13,39 14,21 13,71 13,39
A 10,50 11,80 11,57 10,75 10,50
Recirculation Tee
B 11,49 10,87 11,03 10,52 10,52

Sketch / Photograph

PIPE LINE ECO INLET


Sketch / Photograph Sheet 3 of 3

Drain Pipe & Recirculation Tee