MESSRS. HANJIN HEAVY INDUSTRIES & CONSTRUCTION CO., LTD.

Hull No. : P0089


IMO No. : 9665671

PAUBLIC ADDRESS SYSTEM

45, Namhannam-Ro, Yeongdo-gu, Busan, Korea


Tel : +82 51 412 5551, Fax : +82 51 412 6660
Homepage : www.ehanshin.com
E-mail : [email protected] / [email protected]
COMPONENTS LIST OF " PUBLIC ADDRESS SYSTEM ", HPA-9700
MESSRS. HANJIN HEAVY INDUSTRIES & CONSTRUCTION CO., Hull No. : P0089.
DWG
NO. APPELLATION MODEL RATING REMARKS Q'TY REMARK
No.
1 MAIN UNIT HPA-9721-SD 400W DUAL AC220V & DC24V 1 WHEELHOUSE PA-6
PMC-9721 SINGLE
CONTROLLER UNIT
PMC-9722 DUAL (1)
PGA-9751 SINGLE
GENERAL EM'CY ALARM
PGA-9752 DUAL (1)
PMA-9201 INPUT: DC/200W (2)
POWER AMPLIFIER UNIT PMA-9401 INPUT: AC/400W OUTPUT : 100V WITH STEEL 8T MOUNTING BED
PMA-9402 INPUT: DC/400W 585(W) x 100(H) x 450(D)
AM/FM RADIO/CD PLAYER PCD-9791 (1)
POWER SUPPLY PPM-9731 INPUT: AC/DC (2)
& MONITOR UNIT PPM-9741 INPUT: AC/AC
PFD-9771 SINGLE
FAULT DETECTOR
PFD-9772 DUAL (1)
2 REMOTE CONTROLLER HBC-210F FLUSH TYPE 1 WHEELHOUSE CONSOLE PA-7
A 30W 330Ω W/ J.B (HJB-902A)
HWS-131
B 50W 200Ω W/ J.B (HJB-902A) (15B,10B) 1 COMPASS DECK PA-11
HWS-153 C 75W 135Ω W/ J.B (HJB-902A)
A 15W 680Ω W/10m CORD & PLUG
HWS-150PC B 15W 680Ω W/15m CORD & PLUG
D 15W 680Ω W/25m CORD & PLUG 2 F'CLE DECK, UPP.DECK AFT, PA-13
E/R 2ND PORT(2), INCINERATOR SPACE,
A 5W 2kΩ 1-GLAND, 15Cx1 4
ST'BD & PORT WING. PA-14
B 10W 1kΩ 1-GLAND, 15Cx1 3 EMBARKATION(2), CO2 RM.
C 15W 680Ω
HWS-155 D 20W 500Ω
WATER TIGHT 2-GLAND,
3 A2 5W 2kΩ 3 A.H.U, E/R STORE FWD & AFT.
SPEAKER 20A,15C-1Set / 15Cx2-2Sets PA-15
B2 10W 1kΩ 2-GLAND, 15Cx2 1 T.R RM,
AV2 5W 2kΩ W/VOLUME, 2-GLAND, 20Ax2 2 GALLEY.
PA-17
BV2 10W 1kΩ W/VOLUME, 2-GLAND, 15Cx2 2 EM'CY DG (PORT, ST'BD)
A 1W 10kΩ 2-GLAND, PG16x2 5 COMMON LAVATORY
E/R ENTRANCE, CERW'S PANTRY, PA-18
B 2W 5kΩ 2-GLAND, PG16x2 17
HWS-181 OFFICER'S PANTRY, ETC.
C 5W 2kΩ 2-GLAND
AV 1W 10kΩ 2-GLAND
A 1W 10kΩ FLUSH TYPE, PG16x1 26 CABINS (FOR U.T)
PA-19
HFS-182 B 2W 5kΩ FLUSH TYPE, PG16x1 2 WING (PORT & ST'BD) CONSOLE
BV 2W 5kΩ FLUSH TYPE, W/VOLUME
A 2W 5kΩ ONE SIDE TYPE
HOS-177
B 5W 2kΩ ONE SIDE TYPE
CABIN & PASSAGE A 2W 5kΩ DOUBLE FACE TYPE
HBS-172
4 B 5W 2kΩ DOUBLE FACE TYPE
SPEAKER
A 1W 10kΩ ROUND CEILING TYPE
HFS-173 B 2W 5kΩ ROUND CEILING TYPE 62 ACCOMMODATION
PA-25
C 5W 2kΩ ROUND CEILING TYPE 4 E.C.R(3), W/HOUSE.
MICROPHONE (N.W.T) HDM-720 A HANDY TYPE W/CURL CORD TYPE 3 MAIN, REMOTE, E.C.C. PA-29
A HANDY TYPE W/CURL CORD TYPE
B HANDY TYPE W/10m CORD
C HANDY TYPE W/15m CORD 2 LIFEBOAT EMB.PORT & ST'BD
5 MICROPHONE (W.T) HDM-012
D HANDY TYPE W/20m CORD PA-32
E HANDY TYPE W/25m CORD 4 WINGS, F'CL DECK, UPP.DECK AFT
F HANDY TYPE W/30m CORD
GOOSE NECK MIC.(N.W.T) HDM-930 GOOSE NECK Appr.480mm
FLUSH TYPE MIC. CONN. (5P) 2 WING (PORT & ST'BD) CONSOLE PA-34
HMC-601 A 1-GLAND
WATER TIGHT
6 B 2-GLAND, MIC. CONN. (5P, 3P) 2 LIFE BOAT EMBARKATION (P/S) PA-36
JUNCTION BOX
A 1-GLAND, 20C MIC&SP CONN.(5P, 3P) 2 F'CLE DECK, UPP.DECK AFT, PA-37
HMS-602
B 2-GLAND MIC&SP CONN.(5P, 3P)
2-GLAND, 20C, 15B MATERIAL: POLYESTER 2 For HMC-601B PA-41
7 PROTECTION BOX (W.T)
1-GLAND, 20C MATERIAL: POLYESTER 4 For HMS-602A PA-41-1
HCN-151 FLUSH TYPE MIC. CONNECTOR 1 ECC PA-42
8 N.W.T JUNCTION BOX
HCN-251 FLUSH TYPE JUNCTION BOX FOR MIC
HMH-015 6 For HDM-012 PA-44
9 MICROPHONE HOOK
HMH-016 3 For HDM-720 PA-45
HEG-941D FLUSH TYPE AUTO/MANUAL W/DIMMER 1 W/HOUSE CONSOEL PA-46
10 G.E.A SW BOX HEG-942F FLUSH TYPE AUTO
HEG-941W WALL TYPE AUTO, 1-GLAND, 20Ax1 1 F.C.S PA-48
11 INSTALLATION MATERIAL COPPER PLATE 0.4Tx40Wx500L 1 PA-49-1
12 SPARE PARTS 1 PA-50
NOTE: THE QUANTITIES IN THE PARENTHESIS TO ASSEMBLED TOGETHER WITH MAIN UNIT.
< Contents >
1. General .................................................................................................................................. 2
1.1 General Description ...................................................................................................... 2
1.2 System Feature ............................................................................................................. 2
1.3 System Block Diagram .................................................................................................. 3

2. System Configuration and Specification ................................................................................ 4


2.1 System Description ....................................................................................................... 4
2.2 Main Equipment Outline Drawing .................................................................................. 5
2.3 Electronic Specification ................................................................................................. 6
2.4 Remote Controller ......................................................................................................... 8

3. Installation and Setting .......................................................................................................... 9


3.1 Connection of Accessories .......................................................................................... 13
3.2 Setting of Diode Matrix ................................................................................................ 23
3.3 Setting of Controller .................................................................................................... 26
3.3.1 Controller Board ................................................................................................ 26
3.4 Setting of Alarm Generator .......................................................................................... 29
3.4.1 Alarm generator main Board .............................................................................. 29
3.5 Setting of Fault Detector ............................................................................................. 30
3.5.1 Fault Detector main Board ................................................................................. 30
3.6 Setting of Remote controller ........................................................................................ 31
3.6.1 Remote controller main Board ........................................................................... 31

4. Operation ............................................................................................................................. 32
4.1 Main Controller (PMC-9722) ....................................................................................... 32
4.2 Fault Tolerant Power Amplifier (PMA-9201) ................................................................ 34
4.3 Power Supply & Monitor (PPM-9731) ......................................................................... 35
4.4 General Emergency Alarm Generator (PGA-9752) ..................................................... 36
4.5 Fault Detector (PFD-9772) .......................................................................................... 40
4.6 AM/FM Radio & CD Player (PCD-9791) ..................................................................... 41
4.7 Remote Control Unit (HBC-210F) ............................................................................... 42

5. TROUBLE SHOOTING ........................................................................................................ 44

-1-
1. General
1.1 General Description
HPA-9700 series Public Address/General alarm System is designed for general announcing with
advanced technology, and complies with the SOLAS Chap.Ⅲ/Reg.6.5 & Reg.6.4,
Chap.Ⅶ/LSA Code 7.2, Chap. Ⅱ-2/Res.12, Res. A.830(19), MSC/Circ.808 performance
standards, and Res. A.813(19) & A.694(17).
The system is also specially made to keep a good performance under the bad environment of
vessel at sea.
For this system, paging function through auto-telephone exchanger and talk-back function are
available, and also various interfaces are available.
Selection of output power from 200W up to 4000W, and single or double rack type dual P/A
system according to the customer's request are available.

1.2 System Feature


1) Flexibility in choice of output power.
2) Reliable and durable performance as various function and protection circuitry are mounted
in the power amplifier.
ⓛ Over-load detection circuit is built in
-. Automatic output control when external cable or speaker is short
-. Auto-compensation function for output distortion caused by over-input
-. High sensitivity and high speed breaker switch for cutting over-current
② Over-heat detection circuit is built in
-. Two phase automatic cooling function by thermo detector
3) Simple installation and easy maintenance.
① Each unit is designed to fit 19 inch standard rack size
② System composition is simple, and dual system is composed of one or two cabinet
4) Convenient control for priority change or interface contact change with microprocessor.
5) Automatic changeover for main/emergency power supply.
6) Various interfaces are available.
G.A, Fire alarm, CO2 smoke alarm, Air whistle, Signal column light, VDR,
Fail alarm(Watch Alarm System) and etc.
7) Acquired type approval certificate from the RINA on 28th January 2010.
8) Acquired type approval certificate from the DNV on 23th May 2011.

-2-
1.3 System Block Diagram
1) HPA-9700 Single rack type dual P/A System
Single rack type dual P/A system is designed as following block diagram.
P u b lic A d d r e s s s y s t e m M a in R a c k
N o .1 S p e a k e r L o o p

N o .1 M a in C o n t r o l B o a r d N o .1 I n te r f a c e FU SE
N o .1 R e m o t e M IC -1 B o a rd
c o n t r o lle r R E M O T E -1
D io d e M a trix N o .1 S p e a k e r
C o n t ro l
L o g ic Speaker T e r m in la
M IC -2
P re -
AMP N o .1 A M P
G rou p B o a rd FU SE
N o .2 R e m o t e S e le c t
c o n t r o lle r R E M O T E -2
F a u lt N o .1 M a in F a u lt N o .1 A M P

PABX
M ik e & R e m o te N o .2 S p e a k e r L o o p
M ik e S ig n a ls
T e r m in a l B o a r d
(M IC -3 ~ 1 0 ) N o .2 M a in C o n t r o l B o a r d N o .2 I n te r f a c e FU SE
( O n ly T e r m in a ls ) B o a rd
R a d io A n t e n n a
D io d e M a trix N o .2 S p e a k e r
C o n t ro l
L o g ic Speaker T e r m in la
F a u lt O u t p u t P re -
AMP N o .2 A M P
G rou p B o a rd FU SE
S e le c t
M u te O u tp u t
F a u lt N o .2 M a in F a u lt N o .1 A M P
Alarm singals (Audio)

Mute (Em'cy Speech)

F a u lt N o .1 G A F a u lt N o .2 G A

F a u lt N o .1 M a in F a u lt N o .2 M a in
N o .1
S w it c h B o x F a u lt d e t e c t o r
N o .1 A la r m F a u lt N o .1 A M P F a u lt N o .2 A M P
G e n e ra te B o a rd
N o .2 F a u lt N o .1 P O W F a u lt N o .2 P O W
S w it c h B o x

F a u lt N o .1 G A
F ir e A la r m
S y ste m
Fault Interface

N o .1 P o w e r S u p p ly M A IN P O W E R
A la r m G e n e r a t e & M o n ito r
E M 'C Y P O W E R
T e r m in a l B o a r d
CO2 Sm oke F a u lt N o .1 P O W
A la r m I n p u t

F a u lt N o .2 G A

G a s A la r m
In p u t N o .2 P o w e r S u p p ly
N o .2 A la r m & M o n ito r

O u tp u t G e n e ra te B o a rd
F a u lt N o .2 P O W
S ig n a l ( C o n t a c t)

Fig. 1-1 Block Diagram for Single rack type dual P/A System

-3-
2. System Configuration and Specification

2.1 System Description


H P A - 9 7 X X - D A

A: AC 110V/220V & AC110V/220V


D: AC110V/220V & DC24V

D: Double Rack type Dual P/A system


C: Single Rack type Dual P/A systemⅠ
(Mast & Slave type)
S: Single Rack type Dual P/A systemⅡ
(Two AMP Run type)

00: 35V/ 200W


01: 35V/ 400W
02: 35V/ 600W
03: 35V/ 800W
04: 35V/ 1200W
05: 35V/ 1600W
06: 35V/ 2000W
07: 35V/ 2400W
08: 35V/ 3200W
09: 35V/ 4000W

20: 100V/ 200W


21: 100V/ 400W
22: 100V/ 600W
23: 100V/ 800W
24: 100V/ 1200W
25: 100V/ 1600W
26: 100V/ 2000W
27: 100V/ 2400W
28: 100V/ 3200W
29: 100V/ 4000W

-4-
2.2 Main Equipment Outline Drawing

PUBLIC ADDRESS SYSTEM


HPA-9700

FUSE FUSE

= GA Operation =
Open the protective cover and press the button marked "GA"

= Emergency PA Operation =
1.Open the protective cover and press the button
marked "EM'CY PA"
2.Press and hold the PTT button on mic. and then talk

EM'CY P/A

PCD-9791 CD PLAYER

microphone
DYNAMIC HDM-720

AUDIO ON

POWER

FAULT TEST

TEMP

CLIP

US

E
F
SIGNAL

PROTECT

FAULT TEST

TEMP

CLIP

US
E
F

SIGNAL

PROTECT

PPM-9731 POWER SUPPLY & MONITOR

OFF OFF

VU

VOLUME

MAIN EM'CY

PPM-9731 POWER SUPPLY & MONITOR

OFF OFF

VU

VOLUME

MAIN EM'CY

Notice
This equipment must be installed more than 5m
from a magentic or steering compass.

NP

Fig. 2-1 Outline Drawing for Main Equipment (single rack type dual P/A system)

※ System Component

Item Unit Supply Q’ty


PMC-9722 Main Controller (dual) 1
PMA-9201 Fault Tolerant Power Amplifier (DC/200W) 2
PPM-9731 Power supply & Monitor (AC/DC) 2
Supply PGA-9752 Alarm Generator (dual) 1
PFD-9772 Fault Detector (dual) 1
PCD-9791 AM/FM Radio & CD Player 1
Terminal Board 2

-5-
2.3 Electronic Specification
1) Main Controller
PMC-9722
Power Source AC220V, DC24V
Mic. Volume 300Ω
Alarm 800Hz sine wave
Speaker Selector 9 groups
Dimmer Speaker selector lamp brightness
Busy LED
Main Control board 2 PCB (Dual)

2) Fault Tolerant Power Amplifier


PMA-9201
Power DC24V

Output Voltage 100V

Output Level 200W

Frequency Characteristic 120~12,000㎐ within ±6㏈

Distortion less than 0.5%

S/N Ratio more than 55㏈

3) Power supply & Monitor


PPM-9731
Main : AC220V
Input Power
Emergency : DC24V
Output Power DC24V
Main Power Switch 10A
Emergency Power Switch 40A
Monitor Speaker 5W
Volume controller 300Ω
VU Meter 0dBm

4) Alarm Generator
PGA-9752
Power Source AC220V, DC24V
Automatic G.A 1100Hz square wave, 7 short 1 long
Manual G.A 1100Hz square wave
Fire Alarm 800Hz continuous wave
CO2 Smoke Alarm 400Hz square wave, duty cycle 1.5sec
Gas Alarm 1500Hz square wave, duty cycle 0.5sec
Main Control board 2 PCB (Dual)

-6-
5) Fault Detector
PFD-9772
Input Power : AC220V, DC24V
Indicator :
Output & LED Buzzer Off (Reset)
LED
Buzzer Power Main Amplifier G.A External
Input
LED Buzzer Relay
(Fault) NO.1 NO.2 NO.1 NO.2 NO.1 NO.2 NO.1 NO.2 Contact
NO.1 On Red Gr Gr Gr Gr Gr Gr Gr - Off On
POWER
NO.2 On Gr Red Gr Gr Gr Gr Gr Gr - Off On

NO.1 On Gr Gr Red Gr Gr Gr Gr Gr - Off On


MAIN
NO.2 On Gr Gr Gr Red Gr Gr Gr Gr - Off On

NO.1 On Gr Gr Gr Gr Red Gr Gr Gr - Off On


AMP
NO.2 On Gr Gr Gr Gr Gr Red Gr Gr - Off On

NO.1 On Gr Gr Gr Gr Gr Gr Red Gr - Off On


G.A
NO.2 On Gr Gr Gr Gr Gr Gr Gr Red - Off On

ALL(Off) Off Off Off Off Off Off Off Off Off Off Off Off

※ Remark
• LED Color
Gr(Green) : Normal, Red : Abnormal
• Contact : N.C or N.O

-7-
6) AM/FM Radio & CD Player Specification
PCD-9791
AM/FM Radio Tuner
Receiving System Super-heterodyne system
AM(MW) : 530~1605㎑
Receiving Frequency
FM : 88~108㎒
[FM Tuner]
Usable Sensitivity : 11.3 dBf (1.0㎶/75Ω )
50㏈ Quieting Sensitivity : 16.3 dBf (1.8㎶/75Ω )
Alternate Channel Selectivity (400㎑) : 65㏈
Frequency Response : 40㎐ to 15000㎐
Streo Separation : 35㏈
Capture Ratio : 1.5㏈
[AM Tuner]
Sensitivity : 20㎶
Selectivity : 35㏈
CD Player
Signal Detection System Non-contact optical pickup (semiconductor laser)
Frequency Response 5㎐ to 20000㎐
Wow & Flutter less than 0.3% Wrms
Dynamic Range 96㏈
Signal-to-Noise Ratio 98㏈
Wow and Flutter Less than measurable limit

2.4 Remote Controller


1) Power Source : DC24V (from P/A main unit)
2) Alarm (Call) : 800Hz
3) Microphone with volume
4) Speaker Selector : 9 groups
5) Dimmer : Speaker selector lamp brightness
6) Fault indicator: Main, AMP, GEA, and Power
7) Response Time (RS-485): 500ms
8) Monitor Speaker with volume : 5W

-8-
3. Installation and Setting

1) P/A Terminal Board


Microphones, remote controllers, external alarm interface and AM/FM antenna cables are
connected to terminal board.

Fig. 3-3 Mike & Remote Terminal Board

(1) TB1, TB2 (Connection terminal board for external MIC)


• MIC-1 ~ MIC-3 : Remote Mic.
• MIC-4 ~ MIC-8 : Microphones.
(No.1, No.2: microphone signal input terminal)
(No.3: earth terminal)
(No.4, No.5: key switch input terminal/No.5: ground)
(2) TB3 (Connection terminal board for external MIC, Tel Paging and Alarm Generator)
• MIC-9 ~ MIC-10 : Microphones.
• TEL PAGING: Auto Exchanger(Paging signal)
• ALARM: Alarm Generator
(No.1, No.2: microphone signal input terminal)
(No.3: earth terminal)
(No.4, No.5: key switch input terminal/No.5: ground)
(3) TB4 (Connection terminal for Remote-1, 2, 3, 4, 5, 6)
(4) TB5 (connection terminal for AMS and BK)
• SYS1, SYS2 : System fail contact(N.O)
• POW1, POW2 : Power fail conteact(N.O)
• BK: Breaker line

-9-
2) Speaker Terminal Board

Fig. 3-4 Speaker Terminal Board

(1) TB1, TB2 (Connection terminal board for external speaker)


• SP-1 to 9 : 2 terminals
(No.1: signal, No.2: common)
• SP-10to 15 : 3 terminals
(No.1: general addressing, No.2: emergency addressing, No.3: common)

(2) TB3 (Connection terminal board for Talk back system and external device)
• AUDIO OUT1, AUDIO OUT2 : 0dBm audio signal for talk back system.
(No.1, No.2: microphone signal output terminal – 0dBm)
(No.3: earth terminal)
(No.4, No.5: key switch output terminal)
• CONTACT: Contact output for external device. (N.O or N.C)
• MUTE
-. A1, A2: Contact output for external device. (N.O or N.C)
-. +24V, GND: Mute for Communal Aerial system (HCA-124C)

(3) JUMP 1 ~3
• JUMP 1 : Select Normal Open or Normal Close for Contact A
• JUMP 2 : Select Normal Open or Normal Close for Contact B
• JUMP 3 : Select Normal Open or Normal Close for MUT A

- 10 -
3) G.A Terminal Board

Fig. 3-5 Alarm Generate Terminal Board


(1) TB-1
• AUDIO OUT : Connect to public addressor (audio & key signal)
• INPUT
- OFF: Alarm generator off(mute).
- CO2: Connection terminal for Co2 smoke alarm system (N.O)
- GAS: Connection terminal for GAS alarm System (N.O)
- NC: No connection(spare).
• G.A SWITCH 1 : connection terminal for general alarm switch box (W/H)
• G.A SWITCH 2 : connection terminal for general alarm switch box
• G.A SWITCH 3 : connection terminal for general alarm switch box
• FIRE ALARM: Connection terminal for fire alarm system
- IN : Input (N.O)
- OUT : out signal consists of ring sound of 1 time
after short sound of 7 times (N.O or N.C)
- OFF : fire alarm mute (N.O or N.C)
• AIR HORN : Connection terminal for whistle system.

(2) TB-2
• MUTE : Output contact for mute(N.O)
• GA OUT(7/1) : Out signal consists of ring sound of 1 time after short sound of 7 times
(N.O or N.C)
• GA AUTO : Contact signal when GA AUTO is run.
• GA MAN : Contact signal when GA MANUAL is run.
• S/C GEA : Connection terminal for Signal Light Column(GA).
• S/C FIRE : Connection terminal for Signal Light Column(FIRE).
• S/C CO2 : Connection terminal for Signal Light Column(CO2 smoke).
• S/C GAS: Connection terminal for Signal Light Column(GAS).
• SPARE : Spare terminal (1: +24V, 2: GND)

(3) JUMP 1 ~ 21
• JUMP1: Select Normal Open or Normal Close for GEA AUTO OUT 1

- 11 -
• JUMP2: Select Normal Open or Normal Close for GEA AUTO OUT 2
• JUMP3: Select Normal Open or Normal Close for GEA MAN OUT 1
• JUMP4: Select Normal Open or Normal Close for GEA MAN OUT 2
• JUMP5: Select Normal Open or Normal Close for S/C GAS OUT 1
• JUMP6: Select Normal Open or Normal Close for S/C GAS OUT 2
• JUMP7: Select Normal Open or Normal Close for S/C CO2 OUT 1
• JUMP8: Select Normal Open or Normal Close for S/C CO2 OUT 2
• JUMP9: Select Normal Open or Normal Close for FIRE ALARM OUT
• JUMP10: Select Normal Open or Normal Close for GEA OUT(7/1) OUT 1
• JUMP11: Select Normal Open or Normal Close for GEA OUT(7/1) OUT 2
• JUMP12: Select Normal Open or Normal Close for GEA OUT(7/1) OUT 3
• JUMP13: Select Normal Open or Normal Close for A/HORN
• JUMP14: Select Normal Open or Normal Close for MUTE
• JUMP15: Select Normal Open or Normal Close for FIRE ALARM OFF
• JUMP16: Select Normal Open or Normal Close for S/C FIRE OUT 1
• JUMP17: Select Normal Open or Normal Close for S/C FIRE OUT 2
• JUMP18: Select Normal Open or Normal Close for S/C GEA OUT 1
• JUMP19: Select Normal Open or Normal Close for S/C GEA OUT 2
• JUMP20: Select Normal Open or Normal Close for SPARE OUT 1
• JUMP21: Select Normal Open or Normal Close for SPARE OUT 2

- 12 -
3.1 Connection of Accessories
1) Connection for Remote Controller
◈ Single rack type dual P/A system

PUBLIC ADDRESSOR REMOTE


CONTROLLER
1
(Individual shield-cable) 1
2 2

REMOTE-1
3 3

TB3
4 4
5 5
6 6
7 7
8 8

1
(Common shield-cable) 1
2 2
MIC1

TB1
3 3
4 4
5 5

◈ Double rack type dual P/A system

REM OTE
CO NTROLLER

No.1 TB 3 TB 1 No.2
PUBLIC ADD RESSOR PU BLIC ADDRESSOR

R E M O TE T/B

1 1 1 1
2 2 2 2
REMOTE-1

REMOTE

REMOTE-1

3 3 3 3
4 4 4 4
5 5 5 5
6 6 6 6
7 7 7 7
8 8 8 8

1 1 1 1
2 2 2 2
MIC1

MIC1
MIC

3 3 3 3
4 4 4 4
5 5 5 5

◎ DC+24V : No.3 in the Remote-1


◎ GND : No.5 in the MIC 1

- 13 -
2) Connection for General Alarm System

PUBLIC ADDRESSOR GENERAL


ALARM GENERALTOR
(INSIDE P/A SYSTEM)
1 1

REMOTE T/B

AUDIO OUT
(0 dBm)
2 2

ALARM
MIC &

TB-3

TB-1
(E) 3 3
4 4
(N.O)
5 5
SPEAKER

MUTE

INPUT
TB-3
A1 1

OFF

TB-1
T/B

(N.O)
A2 2

◎ TB-3 ALARM : audio & key signal input


◎ TB-3 MUTE : general alarm mute (N.O)

2-1) Connection for General Alarm Switch Box


◈ Single rack type dual P/A system

GENERAL G.A Switch Box


ALARM GENERALTOR (HEG-941F,FD)
(INSIDE P/A SYSTEM) 1 MANUAL
2 AUTO
MANUAL 1 3 DC24V
SWITCH1

AUTO 2 4 GND
TB1
GA

DC24V 3 5 LAMP
GND 4
LAMP 5
G.A Switch Box
(HEG-942F,W)
GA SWITCH2 ,3

MANUAL 1
AUTO 2 1 MANUAL
TB1

DC24V 3 2 AUTO
GND 4 3 DC24V
LAMP 5 4 GND
5 LAMP

◈ Double rack type dual P/A system


NO.1 NO.2
GENERAL G.A Switch Box GENERAL
ALARM GENERALTOR (HEG-941F,FD) ALARM GENERALTOR
(INSIDE P/A SYSTEM) 1 MANUAL 1 (INSIDE P/A SYSTEM)
2 AUTO 2
MANUAL 1 3 DC24V 3 1 MANUAL
SWITCH1

SWITCH1

AUTO 2 4 GND 4 2 AUTO


GEA
TB1

TB1
GA

DC24V 3 5 LAMP 5 3 DC24V


GND 4 4 GND
LAMP 5 5 LAMP
G.A Switch Box
(HEG-942F,W)
GEA SWITCH2 ,3

GA SWITCH2 ,3

MANUAL 1 1 MANUAL
AUTO 2 1 MANUAL 1 2 AUTO
TB1

TB1

DC24V 3 2 AUTO 2 3 DC24V


GND 4 3 DC24V 3 4 GND
LAMP 5 4 GND 4 5 LAMP
5 LAMP 5

◎ 1 : MANUAL
◎ 2 : AUTO
◎ 3 : 24V (VCC)
◎ 4 : GND
◎ 5 : LAMP

- 14 -
2-2) Connection for External Fire Alarm System
◈ Single rack type dual P/A system

GENERAL
ALARM GENERALTOR
(INSIDE P/A SYSTEM) FIRE ALARM SYSTEM

1
IN (N.O) FIRE RUN(N.O)
2

FIRE ALARM
TB1

1
OUT (7Short/1Long) G.A RUN
2

1
OFF (N.O) FIRE OFF
2

◈ Double rack type dual P/A system

NO.1 NO.2
GENERAL GENERAL
ALARM GENERALTOR ALARM GENERALTOR
(INSIDE P/A SYSTEM) FIRE ALARM SYSTEM (INSIDE P/A SYSTEM)
1 1
IN (N.O) FIRE RUN(N.O) (N.O) IN
2 2
FIRE ALARM

FIRE ALARM
TB1

TB1
1 1
OUT (7Short/1Long) G.A RUN (7Short/1Long) OUT
2 2

1 1
OFF (N.O) FIRE OFF (N.O) OFF
2 2

◎ FIRE ALARM IN : fire alarm generator built in P/A run (N.O)


◎ FIRE ALARM OUT : out signal consists of ring sound of 1 time
after short sound of 7 times (N.O or N.C)
◎ FIRE ALARM OFF : fire alarm mute (N.O or N.C)

- 15 -
2-3) Connection for Light Signal Column
◈ Single rack type dual P/A system

GENERAL
ALARM GENERALTOR
LIGHT SIGNAL
(INSIDE P/A SYSTEM)
COLUMN

1
OUT1 (N.O) G.A RUN

S/C G.A
2
TB2 1
OUT2
2

1
(N.O)
S/C FIRE

OUT1 FIRE RUN


2
TB2

1
OUT2
2

◈ Double rack type dual P/A system


NO.1 NO.2
GENERAL GENERAL
ALARM GENERALTOR ALARM GENERALTOR
(INSIDE P/A SYSTEM) LIGHT SIGNAL (INSIDE P/A SYSTEM)
COLUMN

1 1
OUT1 (N.O) G.A RUN (N.O) OUT1
S/C G.A

S/C G.A
2 2
TB2

TB2
1 1
OUT2 OUT2
2 2

1 1
S/C FIRE

S/C FIRE
OUT1 (N.O) FIRE RUN (N.O) OUT1
2 2
TB2

TB2
1 1
OUT2 OUT2
2 2

◎ S/C G.A : general alarm light signal column run (N.O or N.C)
◎ S/C FIRE : fire alarm light signal column run (N.O or N.C)

- 16 -
2-4) Connection for Whistle Controller
◈ Single rack type dual P/A system

GENERAL
ALARM GENERALTOR
WHISTLE CONTROLL
(INSIDE P/A SYSTEM) SYSTEM

A/HORN
1
TB1
(N.O) INPUT
2

◈ Double rack type dual P/A system

NO.1 NO.2
GENERAL GENERAL
ALARM GENERALTOR ALARM GENERALTOR
(INSIDE P/A SYSTEM) WHISTLE CONTROLL (INSIDE P/A SYSTEM)
SYSTEM
A/HORN

A/HORN
1 1
TB1

TB1
(N.O) INPUT (N.O)
2 2

◎ AIR HORN : whistle system run (N.O or N.C)

- 17 -
2-5) Connection for External Device
◈ Single rack type dual P/A system

GENERAL
ALARM GENERALTOR
(INSIDE P/A SYSTEM)

1
CO 2 (N .O ) CO 2 S M O K E ALA RM SYSTEM
2

INPUT
1

TB1
G AS (N .O ) G AS A LA R M SYSTEM
2
1
NC (N.C) O TH ER DEVICE
2

1
O UT1 (N .O )
S/C CO2

2
TB2

1 LIG H T SIG N AL C O LUM N


O U T2
2
1
(N .O )
S/C GAS

O UT1
2
TB2

1
O U T2
2
1
M U TE (N .O )
2
1 E XTER N AL DEVICE
O UT1 (7S hort/1Long)
GA OUT(7/1)

2
TB2

O UT2 1
(7S hort/1Long)
2

O U T3 1
(7S hort/1Long)
2
1
GA AUTO

O UT1 (N .O )
2
TB2

O UT2 1
(N .O )
2

◈ Double rack type dual P/A system


NO.1 NO.2
GENERAL GENERAL
ALARM GENERALTOR ALARM GENERALTOR
(INSIDE P/A SYSTEM) (INSIDE P/A SYSTEM)

1 1
CO2 (N.O) CO2 SMOKE ALARM SYSTEM (N.O) CO2
2 2
INPUT

INPUT

1 1
TB1

TB1

GAS (N.O) GAS ALARM SYSTEM (N.O) GAS


2 2
1 1
NC (N.C) OTHER DEVICE (N.C) NC
2 2

1 1
OUT1 (N.O) (N.O) OUT1
S/C CO2

S/C CO2

2 2
TB2

TB2

1 LIGHT SIGNAL COLUMN 1


OUT2 OUT2
2 2
1 1
OUT1 (N.O) (N.O) OUT1
S/C GAS

S/C GAS

2 2
TB2

TB2

1 1
OUT2 OUT2
2 2
1 1
MUTE (N.O) (N.O) MUTE
2 2
1 EXTERNAL DEVICE 1
OUT1 (7Short/1Long) (7Short/1Long) OUT1
GA OUT(7/1)

GA OUT(7/1)

2 2
TB2

TB2

OUT2 1 1 OUT2
(7Short/1Long) (7Short/1Long)
2 2

OUT3 1 1 OUT3
(7Short/1Long) (7Short/1Long)
2 2
1 1
GA AUTO

GA AUTO

OUT1 (N.O) (N.O) OUT1


2 2
TB2

TB2

OUT2 1 1 OUT2
(N.O) (N.O)
2 2

◎ SMOKE : CO2 smoke alarm generator built in P/A run (N.O)


◎ GAS : gas alarm generator built in P/A run (N.O)
◎ MUTE : external device (N.O or N.C)
◎ GA AUTO : external device (N.O or N.C)
◎ SPARE : external device (DC24V)

- 18 -
4) Connection to Telephone System

◈ Single rack type dual P/A system

AUTO TELEPHONE
PUBLIC ADDRESSOR
EXCHANGER
VCC

1 L1
2 L2
3
TEL PAGING

K1 4 A1
TB3

5 A1
K2 6 A2
7 A2
K3 8 A3
9 A3

◈ Double rack type dual P/A system

NO.1 AUTO TELEPHONE NO.2


PUBLIC ADDRESSOR EXCHANGER PUBLIC ADDRESSOR
VCC VCC

1 L1 L1 1
2 L2 L2 2
3 3
TEL PAGING

TEL PAGING
K1 4 A1 A1 4 K1
TB3

TB3
5 A1 A1 5
K2 6 A2 A2 6 K2
7 A2 A2 7
K3 8 A3 A3 8 K3
9 A3 A3 9

◎ 1, 2 : Audio signal (0dBm)


◎ 3 : Earth
◎ 4 : Key1, 6 : Key2, 8 : Key3
◎ 5, 7, 9 : GND

- 19 -
5) Connection to Cabin/Pass Speaker
CABIN / PASS. TOILET / MACHINERY
PUBLIC ADDRESSOR
(N.W.T SPEAKER) (W.T SPEAKER)
HCS-176A,B HWS-181A,B,C
MODEL HOS-171A,B MODEL HWS-182A,B,C

SPEAKER TERMINL BOARD

SP10(2ports), ~ SP15(2ports)
HBS-172A,B HWS-155A,B,C

NORMAL NORMAL
1 1 1 1

TB2
EM'CY
2 2
COM COM
3 3 3 3

◎ 1 : NORMAL Output
◎ 2 : EM’CY Output
◎ 3 : COM

6) Connection for Talk Back system


◈ Single rack type dual P/A system

PUBLIC ADDRESSOR
TALK-BACK SYSTEM
SPEAKER TERMINAL BOARD

1 1
AUDIO OUT1

(0 dBm)
2 2
MIC-1
TB-3

(E) 3 3
4 4
(N.O)
5 5

◈ Double rack type dual P/A system


NO.1 NO.2
PUBLIC ADDRESSOR PUBLIC ADDRESSOR
TALK-BACK SYSTEM
SPEAKER TERMINAL BOARD

SPEAKER TERMINAL BOARD

1 1 1 1
AUDIO OUT1

AUDIO OUT1

(0 dBm) (0 dBm)
2 2 2 2
MIC-1

MIC-1
TB-3

TB-3

(E) 3 3 3 3 (E)
4 4 4 4
(N.O) (N.O)
5 5 5 5

◎ MIC
1, 2 : Audio Signal
3 : Earth
4 : Key
5 : GND

- 20 -
7) Connection for BK
◈ Single rack type dual P/A system

PUBLIC ADDRESSOR MF/HF RADIO EQUIPMENT

SSB RADIO RUN


SPEAKER T/B

(B.K IN)
K1 1 BK+
(DC24V)
2 BK-

COMMUNAL AERIAL SYS.


REMOTE T/B
G.A.E RUN
(B.K OUT)
MIC &

K1 A1 G+
TB3

(DC24V)
A2 G-

◈ Double rack type dual P/A system

NO.1 NO.2
PUBLIC ADDRESSOR PUBLIC ADDRESSOR
MF/HF RADIO EQUIPMENT
SSB RADIO RUN

SSB RADIO RUN


SPEAKER T/B

SPEAKER T/B
(B.K IN)

(B.K IN)
K1 1 BK+ BK+ 1 K1
(DC24V) (DC24V)
2 BK- BK- 2

COMMUNAL AERIAL SYS.


REMOTE T/B

REMOTE T/B
G.A.E RUN

G.A.E RUN
(B.K OUT)

(B.K OUT)
MIC &

MIC &
K1 A1 G+ G+ A1 K1
TB3

TB3
(DC24V) (DC24V)
A2 G- G- A2

◎ 1 : BK+ (DC24V)
◎ 2 : BK- (DC0V)

- 21 -
8) Grounding

More than 8 Grounding Copper Plate


(Maker Supply)

Plain Washer
Spring Washer
Plain Washer

Welding Processing

◎ Connect hull and main unit using copper plate (0.4T x 40W x 500L) with picture

- 22 -
3.2 Setting of Diode Matrix

PUBLIC ADDRESSOR DIODE MATRIX


STANDARD (HPA-9700 Series)

CONTACT-1(T/BACK KEY)

CONTACT-3(CONTACT-B)
CONTACT-2(CONTACT-A)

SPARE-1(MUTE-DC24V)
SP1-COMPASS DECK
SP2-F'CLE DK FWD

SP10-CABIN/PASS
SP11-CABIN/PASS
SP12-CABIN/PASS
SP13-CABIN/PASS
SP14-CABIN/PASS
SP15-CABIN/PASS

REMOTE-1 SP SEL
REMOTE-2 SP SEL
REMOTE-3 SP SEL
SP8-MACHINERY
SP9-MACHINERY
SP3-UPP DK AFT

SP7-WING SIDE

MAIN SP SEL

SPARE-2
SP-EMG
SP4
SP5
SP6

A B C D E F G H I J K L M N O P Q R S T U V WX Y

S1-OFF 1 1
S2-COMPASS 2 2
S3-TALK-BACK 3 3
S4-ENG RM 4 4
S5-CABIN/PASS 5 5 REMOTE
S6-ALL 6 6 SPEAKER
S7-SPARE 7 7 SELECTOR
S8-SPARE 8 8
S9-SPARE 9 9
MIC-1 10 10
MIC-2 11 11
MIC-3 12 12
M-MAIN 13 13
M-WING 14 14
MIC-4 15 15
MIC-5 16 16
MIC-6 17 17 MIKE, TEL PAGING
MIC-7 18 18 ALARM, SPEAKER
MIC-8 19 19 SELECTION
MIC-9 20 20
MIC-10 21 21
(ALL)TEL-1 22 22
(GROUP1)TEL-2 23 23
(GROUP2)TEL-3 24 24
ALARM 25 25
EXT 26 26
GA 27 27
S1-OFF 28 28
S2-COMPASS 29 29
S3-TALK-BACK 30 30 MAIN UNIT
S4-ENG RM 31 31 SPEAKER
S5-CABIN/PASS 32 32 SELECTOR
S6-ALL 33 33
S7-SPARE 34 34
S8-SPARE 35 35
S9-SPARE 36 36
37
38
EMERGENCY 39
(MAIN & REMOTE)
A B C D E F G H I J K L M N O P Q R S T U V WX Y

Fig. 3-1 Diode Matrix

- 23 -
Diode matrix consists of remote speaker selector group (1~9),
Mike, Auto Telephone Paging and Alarm speaker selection group (10~27) and main unit
speaker selector group (28~36)
1) Remote Controller Speaker Selector
① No.1 horizontal line indicates selected speaker group
when pressing "OFF" button
② No.2 horizontal line indicates selected speaker group
when pressing "COMPASS" button
③ No.3 horizontal line indicates selected speaker group
when pressing "TALK-BACK" button
④ No.4 horizontal line indicates selected speaker group
when pressing "ENGINE ROOM" button
⑤ No.5 horizontal line indicates selected speaker group
when pressing "CABIN/PASS" button
⑥ No.6 horizontal line indicates selected speaker group
when pressing "EM'CY" button
⑦ No.7 horizontal line indicates selected speaker group
when pressing "SPARE" button
※ P vertical line is able to keep maximum output power of speaker
even though local speaker volume is decreased in minimum.
⑧ No.8, 9 lines are spare speaker group

2) Mike, Tel paging and Alarms Speaker Selection


① No.10 horizontal line indicates selected speaker group
when using external MIC-1.
② No.11 horizontal line indicates selected speaker group
when using external MIC-2.
③ No.12 horizontal line indicates selected speaker group
when using external MIC-3.
④ No.13 horizontal line indicates selected speaker group
when using Main controller MIC.
⑤ NO.14 horizontal line indicates selected speaker group
when using external wing MIC.
⑥ NO.15 horizontal line indicates selected speaker group
when using external MIC-4.
⑦ No.16 line is for MIC-5, No.17 line is for MIC-6, No.18 line is for MIC-7,
No.19 line is for MIC-8, No.20 line is for MIC-9, No.21 line is for MIC-10.
⑧ No.22~24 horizontal line indicates selected speaker group
when using auto-telephone paging.
⑨ No.25 horizontal line indicates selected speaker group
when pressing "ALARM" button of main unit.

- 24 -
⑩ No.26 horizontal line indicates selected speaker group
when pressing "EXT" button of main unit.

⑪ No.27 horizontal line indicates selected speaker group


when pressing "General Alarm" button of main unit.
⑫ No.39 horizontal line indicates selected all speaker group
when pressing " Emergency PA" button of Main & Remote unit.

3) Main Unit Speaker Selector


No.27~35 horizontal line is used for speaker selector of main unit

- 25 -
3.3 Setting of Controller
3.3.1 Controller Board
Set priority of microphone and volume of external microphone

Fig. 3-2 Main control Board

1) DIP1: ID Setting Switch

Main controller ID : Master(No.1) ID : Slave(No.2)

DIP1 ON ON

S/W Setting 1 2 1 2

- 26 -
2) DIP2 : Priority Setting Switch

ON ON

Priority
Mode 0 1 2 3 4
Mode 1 1 2 3 4

① Emergency Speech ① Emergency Speech


①-1. Remote Controller (No.1) ①-1. Remote Controller (No.1)
①-2. Remote Controller (No.2) ①-2. Remote Controller (No.2)
1
①-3. Remote Controller (No.3) ①-3. Remote Controller (No.3)
①-4. Main Controller ①-4. Remote Controller (No.4)
①-5. Main Controller
2 ② General Emergency Alarm ② General Emergency Alarm
③ Normal Speech ③ Normal Speech
③-1. Remote Controller (No.1) ③-1. Remote Controller (No.1)
③-2. Remote Controller (No.2) ③-2. Remote Controller (No.2)
3 ③-3. Remote Controller (No.3) ③-3. Remote Controller (No.3)
③-4. Main Controller ③-4. Remote Controller (No.4)
③-5. MIC (Wing, MIC-4 ~ MIC-10) ③-5. Main Controller
③-6. MIC (Wing, MIC-5 ~ MIC-10)
4 ④ Telephone Paging ④ Telephone Paging
⑤ Entertainment ⑤ Entertainment
5
(Radio, Cassette Tape Player & etc.) (Radio, Cassette Tape Player & etc.)

ON ON

Priority
Mode 2 1 2 3 4
Mode 3 1 2 3 4

① Emergency Speech ① Emergency Speech


①-1. Remote Controller (No.1) ①-1. Remote Controller (No.1)
①-2. Remote Controller (No.2) ①-2. Remote Controller (No.2)
①-3. Remote Controller (No.3) ①-3. Remote Controller (No.3)
1
①-4. Remote Controller (No.4) ①-4. Remote Controller (No.4)
①-5. Remote Controller (No.5) ①-5. Remote Controller (No.5)
①-6. Main Controller ①-6. Remote Controller (No.6)
①-7. Main Controller
2 ② General Emergency Alarm ② General Emergency Alarm
③ Normal Speech ③ Normal Speech
③-1. Remote Controller (No.1) ③-1. Remote Controller (No.1)
③-2. Remote Controller (No.2) ③-2. Remote Controller (No.2)
③-3. Remote Controller (No.3) ③-3. Remote Controller (No.3)
3 ③-4. Remote Controller (No.4) ③-4. Remote Controller (No.4)
③-5. Remote Controller (No.5) ③-5. Remote Controller (No.5)
③-6. Main Controller ③-6. Remote Controller (No.6)
③-7. MIC (Wing, MIC-6 ~ MIC-10) ③-7. Main Controller
③-8. MIC (Wing, MIC-7 ~ MIC-10)
4 ④ Telephone Paging ④ Telephone Paging
⑤ Entertainment ⑤ Entertainment
5
(Radio, Cassette Tape Player & etc.) (Radio, Cassette Tape Player & etc.)

- 27 -
ON ON
Priority
Mode 4 1 2 3 4
Mode 5 1 2 3 4

① Emergency Speech ① Emergency Speech


①-1. Remote Controller (No.1) ①-1. Remote Controller (No.1)
①-2. Remote Controller (No.2) ①-2. Remote Controller (No.2)
①-3. Remote Controller (No.3) ①-3. Remote Controller (No.3)
①-4. Main Controller ①-4. Remote Controller (No.4)
1
①-5. MIC-9(Life Board PORT) ①-5. Remote Controller (No.5)
①-6. MIC-10(Life Board ST’BD) ①-6. Remote Controller (No.6)
①-7. MIC-9(Life Board PORT)
①-8. MIC-10(Life Board ST’BD)
①-9. Main Controller
2 ② General Emergency Alarm ② General Emergency Alarm
③ Normal Speech ③ Normal Speech
③-1. Remote Controller (No.1) ③-1. Remote Controller (No.1)
③-2. Remote Controller (No.2) ③-2. Remote Controller (No.2)
③-3. Remote Controller (No.3) ③-3. Remote Controller (No.3)
3 ③-4. Main Controller ③-4. Remote Controller (No.4)
③-5. MIC (Wing, MIC-4 ~ MIC-8) ③-5. Remote Controller (No.5)
③-6. Remote Controller (No.6)
③-7. MIC (Wing, MIC-7 ~ MIC-8)
③-8. Main Controller
4 ④ Telephone Paging ④ Telephone Paging
⑤ Entertainment ⑤ Entertainment
5
(Radio, Cassette Tape Player & etc.) (Radio, Cassette Tape Player & etc.)

3) Volume Control Resistor (VR1 ~ VR16)


• VR1 : MIC-1 Volume Control
• VR2 : MIC-2 Volume Control
• VR3 : MIC-3 Volume Control
• VR4 : Main MIC Volume Control
• VR5 : WING MIC Volume Control
• VR6 : MIC-4 Volume Control
• VR7 : MIC-5 Volume Control
• VR8 : MIC-6 Volume Control
• VR9 : MIC-7 Volume Control
• VR10 : MIC-8 Volume Control
• VR11 : MIC-9 Volume Control
• VR12 : MIC-10 Volume Control
• VR13 : Telephone Paging Volume Control
• VR14 : Alarm(Call)
• VR15 : EXT Volume Control
• VR16 : G.E.A Volume Control

- 28 -
3.4 Setting of Alarm Generator
3.4.1 Alarm generator main Board

Set ID of Alarm generator

JUMP 1 ID : Master(No.1) ID : Slave(No.2)

Setting
1 3 1 3

- 29 -
3.5 Setting of Fault Detector
3.5.1 Fault Detector main Board

Set ID : Master, Slave Setting


DIP1 ID : Master(No.1) ID : Slave(No.2)
S/W Setting ON ON

1 2 3 4 1 2 3 4

JUMPER5, 6, 7, 8 : Dry Contact output Setting of System or Power Fault


JUMPER Dry Contact NO Output Dry Contact NC Output

5, 6, 7, 8

Setting

JUMPER1, 2, 3, 4 : Power Source Setting


JUMPER AC220V AC110V

1, 2, 3, 4 1 2 3 4 1 2 3 4

Setting
110

110

110

110

110

110

110

110
220

220

220

220

220

220

220

220

JUMPER9: Amp Output Monitor Selector


Tow AMP Run Type Tow AMP Change Type

JUMP9 Setting

- 30 -
3.6 Setting of Remote controller
3.6.1 Remote controller main Board

Set ID of Remote controller : Switch2 ~ Switch5 of DIP1


ID : No.1 ID : No.2 ID : No.3

ON ON ON

1 2 3 4 5 1 2 3 4 5 1 2 3 4 5
DIP1

S/W Setting ID : No.4 ID : No.5 ID : No.6

ON ON ON

1 2 3 4 5 1 2 3 4 5 1 2 3 4 5

Set multi speaker select ON/OFF : Switch1 of DIP1


Multi OFF Multi ON
DIP1 ON ON
S/W Setting
1 2 3 4 5 1 2 3 4 5

- 31 -
4. Operation
4.1 Main Controller (PMC-9722)
Main control unit controls the whole P/A system and enables announcing to the required area
by selecting speaker group when main microphone is operated. In case of using the external
microphone, operated speaker group is already assigned by diode matrix circuit and can be
changed if necessary.
3 8 9 7

PMC-9722 MAIN CONTROLLER

NO.1

RUN
COM- TALK
OFF TEST
PASS BACK

BUSY FAIL
EM'CY PA

DIMMER VOLUME
NO.2

RUN

ALL ALARM TEST

FAIL
MIC

1 2 10 11 4 5 6

Fig. 4-1 Main Controller (PMC-9722, Dual)

① Speaker Group Selector


It is used for selecting speaker group for announcing when using main microphone.
• OFF
It is used for stop operating of all speakers and out-put power can be checked by monitor
speaker.
• COMPASS
It is used for announcing to compass deck.
• TALK BACK
It is used for talk-back each other where Mic. and speaker are fitted.
• E/R
It is used for announcing to engine room.
• CABIN/PASS
It is used for announcing to cabin and passage.
• EM'CY
It is used for emergency announcing to all regions, and announce with max. output of
speak even though the local speaker is set in the low volume or off condition.
(Microphone is max. volume)
• SPARE
Spare select button

② ALARM
It is used for pre-announcing signal. (not duplication)
③ BUSY
This lamp indicates the system on.

- 32 -
④ DIMMER
It is used for brightness control of LED indicator.
⑤ VOLUME
It is used for volume control.
⑥ MIC
It is used for connecting with microphone.

⑦ OVERRIDE
Main control unit has first priority.

⑧ NO.1 TEST

It is used for fail test of No.1 Main control board.

⑨ NO.1 RUN/FAIL

• RUN : green LED lights when system is in normal working


• FAULT : red LED lights when system is in abnormal working
⑩ NO.2 TEST

It is used for fail test of No.2 Main control board.

⑪ NO.2 RUN/FAIL

• RUN : green LED lights when system is in normal working


• FAULT : red LED lights when system is in abnormal working

- 33 -
4.2 Fault Tolerant Power Amplifier (PMA-9201)

FAULT TEST

TEMP

CLIP

US
E
F

SIGNAL

PROTECT

1 3

Fig. 4-2 Fault Tolerant Power Amplifier (PMA-9201, DC, 200W)

1) Front panel Switch & Lamp


① FUSE Holder
② FAULT TEST
Fault test button
③ LED Indicator
• TEMP
Indicates that temperature of the internal amplifier is more than 75℃
• CLIP
Indicates that input signal is bigger than normal signal level
• SIGNAL
Indicates that external signal comes in
• PROTECT
Green light indicates the condition is normal
Orange light indicates the output power is off

2) Power Amplifier
Various function and protection circuits are mounted in this power amplifier to keep reliable
and durable performance.
① Over-heat detection
② two phase auto-freezing by thermo detector
③ AC output detection
④ Distortion detection
Automatic gain control circuit
⑤ Overload detection
High speed and sensitive breaker switch against over current
⑥ Automatic output control and transfer

- 34 -
4.3 Power Supply & Monitor (PPM-9731)

Fig. 4-3 Power Supply & Monitor (PPM-9731)


① Power Switch
• MAIN
Main power on/off switch (AC110V/220V)
• EM'CY
Emergency power on/off switch (DC24V)
※ automatic switch-over from main to emergency when main power is in trouble
② VU Meter
Indicates level of output signal from P/A
③ VOLUME knob
volume control knob for monitor speaker
④ Monitor Speaker
Audio check for monitor speaker

- 35 -
4.4 General Emergency Alarm Generator (PGA-9752)

G.A generator is operated with micro-processor to control various signals and designed for
compact system. General emergency alarm, fire alarm and CO2 smoke alarm functions are
available.
G.A generator is operated by external no.1, no.2 and no.3 switch box In case of no.1 switch
box operating, air horn starts to work, and in case of no.2 and no.3 switch box operating, air
horn doesn't work. Fire alarm or smoke alarm is operated by external input of relay contact.

PGA-9752
NO.2
FAULT TEST FAULT TEST

RUN RUN

FUSE FUSE
FAULT GA MANUAL FIRE CO2 GAS FAULT

1 2 3 4 5

Fig. 4-4 General Alarm Generator-Dual


① NO.1 FUSE : No.1 Alarm generator fuse
NO.1 TEST : It is used for fail test of No.1 Alarm generator.

② NO.1 RUN/FAULT
• RUN : green LED lights when system is in normal working
• FAULT : red LED lights when system is in abnormal working
③ Alarm Push button
• GA
Automatic generates for audio signal of 1100Hz pulse square wave repeatedly
7 times on/off with 1sec interval and/then on for 7sec and off for 3sec.
• MANUAL
Manual operates like morse signal (1100Hz pulse square wave)
• FIRE
800Hz continuous wave
• CO2
400Hz square wave, duty cycle 1.5sec
• GAS
1500Hz Square wave, duty cycle 0.5sec

④ NO.2 FUSE : No.2 Alarm generator fuse.


NO.2 TEST : It is used for fail test of No.2 Alarm generator.

⑤ NO.2 RUN/FAULT
• RUN : green LED lights when system is in normal working
• FAULT : red LED lights when system is in abnormal working

- 36 -
※ Specification and Kind of Signal

① GA
Automatic generation for audio signal of 1100Hz pulse square wave repeatedly 7 times
on/off with 1sec interval and/then on for 7sec and off for 3sec.

1100Hz 1s 1s 7s 3s REPEAT

Output timing(relay contact) of microphone key and fire alarm off signal

Output timing(relay contact) of fire alarm, P/A and horn signal

1s 1s 7s 3s REPEAT

② MANUAL
Manual generation for audio signal of 1100Hz pulse square wave

1100Hz

Output timing(relay contact) of mic. key, fire alarm off, P/A and air horn signal

③ Fire
800Hz continuous signal automatically generation

800Hz

output timing(relay contact) of microphone key

- 37 -
④ CO2
Automatic generation for audio signal of 400Hz square pulse signal with 1.5sec interval

1.5S 1.5S 400Hz

Output timing(relay contact) of microphone key

⑤ GAS
Automatic generation for audio signal of 1500Hz square pulse signal with 0.5sec interval
0 .5 S 0 .5 S 1500H z

Output timing(relay contact) of microphone key

- 38 -
⑥ Relation of External Input and Output of Alarm Signal
Signal output (relay contact)
Output Audio Fire alarm GA
AIR S/C S/C S/C S/C Priority Remark
Input output MUTE OUT GA MAN
OFF OUT HORN (7/1)
GA Fire CO2 GAS

Em’cy
GA Off × O × × O × × × × × × × ①
PA
GA
GA O × # # × # O × O × × × ②
SW.1
MANUAL O × × × × × × O × × × × ⑤
GA
GA O × # # × # O × O × × × ③
SW.2
MANUAL O × × × × × × O × × × × ⑥
GA
GA O × # # × # O × O × × × ④
SW.3
MANUAL O × × × × × × O × × × × ⑦
Fire O × × × × × × × × O × × ⑧
CO2 Smoke O × × × × × × × × × O × ⑨
Gas O × × × × × × × × × × O ⑩

※ Remark
• # (Signal relay contact)
7 times on/off with 1sec interval and/then on for 7sec, and off for 3sec.
• Relay contact of signal output for starting air horn can be controlled by
no.1 switch box only in the wheel house.
• When G. A is in automatic operation, relay contact signal only can be output
and audio signal is not included.
• Contact : N.O or N.C

- 39 -
4.5 Fault Detector (PFD-9772)

1 2 3 4

Fig. 4-5 Fault Detector (PFD-9772, Dual)


① BZ SWITCH
When power source is failed, the buzzer sounds,
if buzzer switch is off, just buzzer sound stops and LED color will not be changed.
② BUZZER
Fault buzzer
③ DIMMER
It is used for brightness control of LED indicator.
④ LED
When the system is normal, Green LED lights on.
When the system is abnormal, Red LED lights on.

※ Refer to “2.3 Electronic Specification, 7) Fault Detector”

- 40 -
4.6 AM/FM Radio & CD Player (PCD-9791)
* refer to attached Instruction Manual for AM/FM Radio & CD Player
PCD-9791 CD PLAYER

AUDIO ON
POWER

1 2 3

Fig. 4-6 AM/FM Radio & CD Player (PCD-9791)

① Power switch for AM/FM Radio & CD Player


② Audio ON
③ AM/FM Radio & CD Player

- 41 -
4.7 Remote Control Unit (HBC-210F)
Remote controller has same function as main control unit, and it is installed normally
in the bridge control console.

[MAX] [MAX]
10 10
9 9
8 8
7 7
6 6
5 5
4 4
3 3
2 2
1 1
[MIN] [MIN]

FAULT SPEAKER SELECTOR

COM- TALK
OFF E/R
PASS BACK

CABIN
ALARM
PASS

MIC POWER

Fig. 4-7 Remote Controller (HBC-210F)

① OUT
Level meter
Indicates output of signals with digital level in P/A
② MONI
Monitor speaker level indicator
Indicates output of monitor speaker with digital level
③ MIC
Microphone volume level indicator
Indicates microphone volume level
④ MONI
Monitor speaker volume control button
It is used for controlling the volume of monitor speaker.
⑤ MIC
Microphone volume control button
It is used for controlling the volume of microphone.
⑥ SPEAKER SELECTOR
Speaker group selector button
It is used for selecting group for addressing when microphone is used.
• OFF
It is used for stop operating of all speaker, and output power can be checked by monitor
speaker of main unit.

• COMPASS
It is used for addressing to compass deck.

- 42 -
• TALK BACK
It is used for talk-back each other where microphone and speaker are fitted.
• E/R
It is used for addressing to engine room.
• ALL
It is used for speech to all regions,
• CABIN/PASS
It is used for addressing to cabin and passage.
• SPARE
Spare button
⑦ ALARM
It is used for pre-addressing with audio signal of 800Hz flat sine wave. (not duplication)
⑧ POWER
Power on/off switch
⑨ EM’CY PA
Priority of remote controller became to no.1 priority
It is used for emergency speech to all regions,
and announce with maximum output of speak even though
if the local speaker is set in the low volume.
(microphone volume is max.)

⑩ MIC
It is used for connecting microphone.
⑪ FAULT
Fault LED indicate “off” when P/A system is normal operating.
• POWER
Power fail : red
• PA
Public addressor fail : red
• GA
Alarm Generator fail : red
⑫ Monitor Speaker
It is used for audio check of monitor speaker.
⑬ DIMMER
It is used for brightness control of LED indicator.
⑭ EM’CY PA Operation
1. Open the protective cover and press the button marked “EM’CY PA”.
2. Press and hold the PTT button on mic. and then talk.

- 43 -
5. TROUBLE SHOOTING
Item Symptom Check Point and Countermeasure

All power failure,


Whole Check main and emergency switch is on.
No MAIN & EM’CY
System Check Main/emergency power supply voltage.
LED illuminates

Power MAIN & EM'CY LED


Check main and emergency switch is on.
Detector illuminates,
Check main/emergency power supply voltage.
Unit Buzzer sounds

Check Mike Cable No.3 : Earth


Mike Mike noise Refer. 3.1 connection of accessories
6) Connection for Talk Back system

Separate Main control unit from rack,


Check fuse (F1~F4) in control unit.
Power failure
Check voltage in No.5/No.6 terminal of connector(J5).
If no AC 24V power, replace transformer.

All speaker group


Check dimmer volume.
select button LED
If volume control is defective, replace dimmer volume.
goes out

Check “BUSY” LED ON Î Check Mike priority


Control Check MIC connector is inserted upright.
Main microphone
Adjust volume.
Unit does not operate
Check speaker group select button is on.
Check cable of inner microphone.

BUSY LED Power off, check external MIC and telephone terminal
always illuminates (No.4 & No.5) in terminal board.
If shorted, check external cable and equipment.

Radio/Cassette deck Check radio/cassette tape/CD player is power on.


/CD player does not Check "PTT" button is on.
operate Check required speaker group select button is on.

Power failure Check power switch is on.


Check fuse(F1~F5) in G.A unit.

G.A Test operation by G.A main unit.


G.A switch box
Unit If normal condition, check GA switch box cable.
does not operate
If defective condition, replace GA switch box.

G.A main unit Power off G.A main unit.


does not operate Check override switch is on.

- 44 -
Item Symptom Check Point and Countermeasure

No sound for
Monitor monitor speaker
Adjust monitor volume.
Unit in spite of
P/A is running

Check power switch is on.


Power failure
Check fuse in power amp unit.
Power
Amp.
Check speaker group select button is on.
Unit Signal LED
Check cable for output of amp and external speaker terminal in
illuminates,
terminal board.
No output power
If speaker cable is shorted, no output or weak sound.

Check P/A main unit is in normal operation.


Check remote unit power switch is on.
Power failure Check fuse(F1) in remote control unit.
Check terminal voltage No.5(GND: Mic. cable)
for Mic. cable and No.3 (+24V) for remote-1/2(TB-4) in terminal
Remote board.
Control
Unit Check Mic. connector is inserted upright.
Microphone Adjust volume.
does not operate Check speaker group select switch is on.
Test with other normal microphone.

No sound Adjust volume.


monitor speaker Monitor speaker is off when using of remote Mic.

Check speaker cable No.1~3


Speaker Speaker is abnormal Refer. 3.1 Connection of Accessories
5) connection to Cabin/Pass speaker

- 45 -
5 4 3 2 1

Main Controller (No.1 & No.2)


POW-1 POW-2
No.1/JP1 No.2/JP1
KEY&SEL-1 KEY&SEL-2
No.1/JP2 No.2/JP2
0dBm-1 0dBm-2
No.1/JP3-A No.2/JP3-A
M-AUDIO-1 M-AUDIO-2
No.1/JP4 No.2/JP4
D MATRIX-1 MATRIX-2 D
No.1/JP5-A No.2/JP5-A

Alarm generator (No.1 & No.2)


No.1/JP1 No.2/JP1
JP2-B JP2-B
No.1/JP2-A No.2/JP2-A

Fault Tolerant Power Amplifier(No.1) Fault Detector Fault Tolerant Power Amplifier(No.2)
JP1 JP2
AUDIO AUDIO
JP2 JP2
JP3

JP1 JP1

Cassette Tape & CD Player


C C

Interface Board (No.1) JP1 Interface Board(No.2)


J5
MATRIX-1 MATRIX-2
JP1 JP2 JP1
JP5-A JP5-A
Entertainment
0dBm-1 0dBm-2
JP6-A JP6 JP6 JP6-A
POW-1 POW-2
JP14 JP14

JP13 JP13
Power Supply & Monitor (No.1)
JP11 JP2 JP11

JP10 JP1 JP10

JP9 JP9

JP8 Power Supply & Monitor (No.2) JP8

JP2 JP2-A
JP2A JP2-B
JP2-B

JP4 JP3 JP1 JP3 JP4


JP7

JP7

Mike & Remote Terminal Board

JP1 J2
B
Speaker Terminal Board(No.1) M-AUDIO-1 M-AUDIO-2 Speaker Terminal Board(No.2) B
JP2-A JP2-B

KEY&SEL-1 KEY&SEL-2
JP3-A JP3-B

JP1-A JP1-A
JP1-B JP1-B
JP4-A JP4-B

JP2 JP2
TB3(GEA) JP5
J1

TB3 (MUTE1) TB3 (MUTE1)

AM/FM ANT.

Alarm Generate Terminal Board

Power Terminal No.1 Audio Out GEA OFF Power Terminal No.2
OUT JP1 OUT
IN

IN

No.1 POWER No.2 POWER


A
(Main/Em'cy Power) (Main/Em'cy Power) A

Apprvd
Hanshin Electronics Co., Ltd.
Chckd Scale Title
HPA-97XX P/A System Diagram II
Drwn Size Doc. No. Rev
Custom PMP-970C-161 1.0a
Date: 2009. 05. 16 Sheet 1 of 1