Nivotemp NT 64: Level and Temperature Switch With Display NV64D
Nivotemp NT 64: Level and Temperature Switch With Display NV64D
65
0,85 kg/dm³ with float SK 221
length 280, 370, 500
F000009D
L1= min 30
first contact
Material / Design MS VA
4
float hard PU (SK 601) 1.4571 (SK 221)
immersion tube brass 1.4571
flange (DIN 24557) PA PA
L2= min 70
Level contacts K W
function fO / fC* change over
stilling tube
max. quantity 4 2
optional
max. voltage 30 V 30 V
max. current 0,5 A 0,5 A
max. contact load 10 VA 20 VA ø50 (MS)
min. distance of contact 40 mm 40 mm last ø60,3 (VA)
contact
min. 60
*fO= falling opener / fC = falling closer
included in delivery
fixing bolts (6 pieces) and GI cork-gasket
3,5
ø44
Temperature contact TK
max. voltage 30 V
max. current 2,5 A
max. contact load 100 VA O
Function NC NO
P Installation dimension
switching point °C 50 / 60 / 70 / 80 50 / 60 / 70 / 80
min. Ø60
switching point tolerance ±3K ±3K min. Ø61 with
max. hysteresis 10 K ± 3 K 10 K ± 3 K T stilling tube
NC = opener / NO = closer (figures at increasing temperature)
I
Temperature sensor Pt 100 class B, DIN EN 60751
73
90
tolerance ±0,8°C
O 6xØ6
Temperature transmitter KT
probe element Pt 100 class B, DIN EN 60751 according to DIN 24557 part 2
N
measuring range 0 °C to +100 °C
operating voltage (UB) 10 - 30 V DC
output 4 - 20 mA A
load W max. (UB -7,5 V) / 0,02 A
other measurement ranges on request
L
Option
SSR - stilling tube material same as immersion tube
Connector M3 S6 M12 (base) 2 x M12 (base)
3 pol. + PE 6 pol. + PE 4 pol. 2 x 4 pol.
DIN EN175301-803 DIN EN 175201-804
max. voltage 30 V AC/DC 30 V AC/DC 30 V DC 30 V DC
protection class IP 65 IP 65 IP 67** IP 67**
cable connection PG 11 M20 x 1,5
37 47 M12x1 M12x1
M12x1
65
65
A B
58
45
DE 10 0209
05/2009
Page 2/6 we reserve the right to amend specifications
Product code for NT 64
NT 64-
Series
Nivotemp NT 64
Design
MS brass Accessories
VA float and immersion tube VA SSR = stilling tube
Connector Temperature
M3
S6 Pt 100 = Temperature sensor (RTD)
M12 KT = Temperature transmitter
2M12
TK = Temperature contact
Length
T50NO = 50 °C closer
280
T60NO = 60 °C closer
370
T70NO = 70 °C closer
500
T80NO = 80 °C closer
Quantity level contacts
1-4 T50NC = 50 °C opener
T60NC = 60 °C opener
Level contact T70NC = 70 °C opener
K = opener / closer T80NC = 80 °C opener
W = change over
L1 L1 L1 L1
1 2 1 2 1 4 1 4
only level contact(s) L2 L2 L2 L2
3 3 2 A 2
L3
Type K PE
L4
4 3 3
L3
5 1 4
6 L4
B 2
PE 3
1 L1 2 1 L1 2 1 L1 4 1 L1 4
only level contact(s) 3 3 2 A 2
Type W PE L2 4 3 3
5 1 L2 4
6 B 2
PE 3
L1 L1 L1
1 1 2 1 4
2 L2
Level contact(s) 3
3 2
L3
Type K TK / KT 4 TK / KT
PE 3
5 6
and temperature
TK / KT PE
1 L1 2 1 L1 4
Level contact(s) 3 A 2
Type W 4 3
5 6
and temperature TK / KT
1 4
PE B 2
PT
TK / KT PT 3
L1 L1
1 2 1 4
Level contact(s) L2 L2
3 A 2
L3
Type K 4 3
12
lengths 280, 370, 500
Material / Design MS VA
display housing PA PA
116
float hard PU (SK 601) 1.4571 (SK 221)
immersion tube brass 1.4571
flange (DIN 24557) PA PA
SSR (option) brass VA
4
Level contacts K10
max. quantity 2 GI-cork gasket
function fC / fO*
max. voltage 30 V
L1=min.40
L2
max. current 0,5 A
F000561
max. contact load 10 VA
min. distance of contact 40 mm
*fO= falling opener / fC = falling closer
L
fixing bolts (6 pieces) and GI cork-gasket
Display
SK601
temperature display range -20 °C to +120 °C (4 °F to 248 °F) SSR
indication range alarm 0 °C to 100 °C (32 °F to 178 °F) stilling tube
accuracy 1% with support ring
resolution 0,5 °C (1 °F)
min.60
-2T L
connector (base) 2 x M12 - 4 pol
Ø90
Ø73
-4T T
connector (base) 1 x M12 - 4 pol.
1 x M12 - 8 pol. I
max. contact load 1A
PNP transistor output, 4 x free programmable V
current PNP output max. 0,5 A per output
max. 1 A overall E
O
Option
stilling tube SSR
P
Material as immersion tube T.
DE 10 0209
05/2009
Page 4/6 we reserve the right to amend specificationsn
Product code for NT 64D
NT 64D- -2M12
Series
Nivotemp NT 64D -2T
LED Temperature display
Design 2 x Temperature output
MS brass ®
Accessories:
Part No. Description
91 44 05 0010 Connecting cable M12x1, 4-pol., 1,5 m, elbow connector (female) and straight connector (male)
91 44 05 0046 Connecting cable M12x1, 4-pol., 3,0 m, elbow connector (female) and straight connector (male)
91 44 05 0047 Connecting cable M12x1, 4-pol., 5,0 m, elbow connector (female) and wire
91 44 05 0048 Connecting cable M12x1, 8-pol., 1,5 m, elbow connector (female) and straight connector (male)
91 44 05 0049 Connecting cable M12x1, 8-pol., 3,0 m, elbow connector (female) and straight connector (male)
91 44 05 0033 Connecting cable M12x1, 8-pol., 5,0 m, elbow connector (female) and wire
Connector A = level L1 L1 L1
1 4 1 4 1 4
2 L2 L2 L2
2 2 2
1
3 4 3 3 3
1 +24 V DC
1 +24 V DC 1 +24 V DC 3 GND 2
3 GND 3 GND 3 8
Connector B = temperature 2 OUT 2
Display
2 unit 5 OUT 3 7
1 5
Pt 100
(RTD)
Pt 100
(RTD)
3 6
4 4 T1 (PNP) 4 T1 (PNP) 6 OUT 4
2 T2 (PNP) 2 Analog out Pt 100
(RTD)
DE 10 0209
05/2009
Page 5/6 we reserve the right to amend specifications
Das EasyJust System
10 (adjustability) contact strip with cm scale
Using adjustable level contacts allows the application of standardised immersion tubes in oil tanks of different sizes
and geometrical shapes.
The switching points are changeable to the requirement of the individual application at any time without purchasing
a specific level switch.
This facilitates design and logistics for the users and OEMs.
The level contacts are electric items which need to be in contact with the respective circuit. Therefore normally wires
are used which results in difficult adjustability when using several contacts.
The contacts’ function (fO or fC) is determined by the 180° rotation on the printed circuit board.
An adjusted temperature switch (bi-metal, NO or NC), a Pt 100 (RTD) or a 4-20 mA transmitter is fixed at the lower
end of the printed circuit board, depending on the chosen option for the temperature surveillance.
DE 10 0209
05/2009
Page 6/6 we reserve the right to amend specifications