Guide To Design of Simply Supported Slabs
Guide To Design of Simply Supported Slabs
Simply supported slabs are supported on columns or stanchions. They have support
on all four sides.
One way slabs bend in one direction only and transfer their loads to the two support
beams in opposite directions. Their main steel in on shorter span length. L/B ratio is
generally less than 2.
Two way slabs bend in both directions, and transfer their loads and stresses on all
four sides. L/B ratio is equal to or greater than 2.
Simply supported slabs don’t give adequate provision to resist torsion at corner to
prevent corner from lifting.
Cl D-2.1.1 The maximum bending moment will be given if the slabs are restrained.
But atleast 50% of the tension reinforcement provided at the mid span should
extend to the support. The remaining 50% should extend to within 0.1Lx or Ly at
the support as appropriate.
RCC Slab Design depends on the on the dimensions of the slab after which the slab
is termed as a one-way slab or a two-way slab…
Calculated value
3xd
300mm
Spacing of distribution bars
The spacing or c/c distance of distribution bars shall not exceed the following
Calculated area
5xd
450mm
Diameter of bars Cl 26.5.2.1
The diameter of the bars varies from 8mm to 14mm and should not exceed 1/8 th of
the overall depth of the slab.
For distribution steel, the diameter varies from 6mm to 8mm.
Cover
The bottom cover for reinforcement shall not be less than 15mm or less than the
diameter of such bar.
RCC Slab Design Guidelines:
b) Depth of slab:
The depth of slab depends on bending moment and deflection criterion. the trail
depth can be obtained using:
Simply supported
Fe-250 - L/35
Fe-415 - L/28
Continuous support
Fe-250 - L/40
Fe-415 - L/32
c) Load on slab:
The load on slab comprises of Dead load, floor finish and live load. The loads are
calculated per unit area (load/m2).
a) Nominal Cover:
However, if the diameter of bar do not exceed 12 mm, or cover may be reduced by 5
mm. Thus for main reinforcement up to 12 mm diameter bar and for mild exposure,
the nominal cover is 15 mm.