3. SF6 gas
(a) is yellow in colour
(b) is lighter than air
(c) is nontoxic
(d) has pungent small
(e) none of the above
Ans: c
6. With which of the following, a circuit breaker must be equipped for remote
operation ?
(a) Inverse time trip
(b) Time-delay trip
(c) Shunt trip
(d) None of the above
1
(e) All of the above
Ans: c
13. Thermal overload relays are used to protect the motor against over
current due to
(a) short-circuits
(b) heavy loads
(c) grounds
(d) all of the above
Ans: b
2
14. Magnetic circuit breaker has ______ trip action.
(a) delayed
(b) instantaneous
(c) both of the above
(d) none of the above
Ans: b
17.In order that current should flow without causing excessive heating or
voltage drop, the relay contacts should
(a) have low contact resistance
(b) be clean and smooth
(c) be of sufficient size and proper shape
(d) have all above properties
Ans: d
20. The current zero interruption, in oil and air blast circuit breakers, is
achieved by
(a) lengthening of the gap
(b) cooling and blast effect
(c) both (a) and (b)
(d) deionizing the oil with forced air
(e) none of the above
Ans: c
3
21. Air blast circuit breaker is used for
(a) over currents
(b) short duty
(c) intermittant duty
(d) repeated duty
Ans: d
30. The voltage appearing across the contacts after opening of the circuit
breaker is called______voltage.
(a) recovery
(b) surge
(c) operating
(d) arc
(e) none of the above
Ans: a
40. The ground wire should not be smaller than No ______ copper.
(a) 2
(b) 4
(c) 6
(d) 10
Ans: d
41. The delay fuses are used for the protection of ________ .
(a) motors
(b) power outlet circuits
(c) fluorescent lamps
(d) light circuits
Ans: a
44. The contacts of high voltage switches used in power system are
submerged in oil. The main purpose of the oil is to
(a) lubricate the contacts
(b) insulate the contacts from switch body
(c) extinguish the arc
(d) all of the above
(e) none of the above
Ans: c
46. To protect most of the electrical equipment handling low power, the
types of relays used are
(a) thermocouple
(b) electronic and bimetallic
(c) both (a) and (b)
(d) none of the above
Ans: c
62. For cost and safety, the outdoor substations are installed for voltages
above
(a) 11 kV
(b) 33 kV
(c) 60kV
(d) 110kV
Ans: b
63. The short circuit in any winding of the transformer is the result of
(a) mechanical vibration
(b) insulation failure
(c) loose connection
(d) impulse voltage
Ans: d
9
64. relays are used for phase faults on long line.
(a) Impedance
(b) Reactance
(c) Either of the above
(d) None of the above
Ans: a
10
71.The relay with inverse time characteristic will operate within
(a) 1.5 sec
(b) 5 to 10 sec
(c) 5 to 20 sec
(d) 20 to 30 sec
(e) none of the above
Ans: b
72. The single phasing relays are used for the protection of
(a) single phase motors only
(b) two phase motors only
(c) two single phase motors running in parallel
(d) three phase motors
Ans: d
73. Which of the following devices will receive voltage surge first
travelling on the transmission line ?
(a) Lightning arresters
(b) Relays
(c) Step-down transformer
(d) Switchgear
Ans: a
74. Which of the following parameter can be neglected for a short line ?
(a) Inductance
(b) Capacitance
(c) Resistance
(d) Reactance
Ans: b
76. Which of the following circuit breakers has high reliability and
minimum maintenance ?
(a) Air blast circuit breakers
(b) Circuit breaker with SF6 gas
(c) Vacuum circuit breakers
(d) Oil circuit breakers
Ans: b
79. What will be the reflection co-efficient of the wave of load connected
to transmission line if surge impedance of the line is equal to load ?
(a) Zero
(b) Unity
(c) Infinity
(d) None of the above
Ans: a
80. The inverse definite mean time relays are used for over current and
earth fault protection of transformer against
(a) heavy loads
(b) internal short-circuits
(c) external short-circuits
(d) all of the above
Ans: b
82. Air blast circuit breakers for 400 kV power system are designed to
operate in
(a) 100 microsecond
(b) 50 millisecond
(c) 0.5 sec
(d) 0.1 sec
Ans: b
87. If the fault occurs near the impedance relay, the VII ratio will be
(a) constant for all distances
(b) lower than that of if fault occurs away from the relay
(c) higher than that of if fault occurs away from the relay
(d) none of the above
Ans: b
88. The torque produced in induction type relay (shaded pole structure)
is
(a) inversely proportional to the current
(b) inversely proportional to the square of the current
(c) proportional to the current
(d) proportional to square of the current
Ans: b
89. The steady state stability of the power system can be increased by
(a) connecting lines in parallel
(b) connecting lines in series
(e) using machines of high impedance
(d) reducing the excitation of machines
(e) none of the above
Ans: a
13
(d) none of the above
Ans: a
15
(d) reactors
Ans: d
109. In a single bus-bar system there will be complete shut down when
(a) fault occurs on the bus itself
(b) fault occurs on neutral line
(c) two or more faults occur simultaneously
(d) fault occurs with respect to earthing
Ans: a
110. Which device is used for protection of equipment from from damage
caused by overload or short circuit?
(a) CVT
(b) Circuit Breaker
(c) Current Transformer
(d) Lighting Arrester
Ans: b
111. Isolator in substation is open under ------------- condition?
(a) No load
(b) Short Circuit
(c) Full Load
(d) Any of the above
Ans: a
112. Earthling switch is used for
(a) measuring of safety voltage
(b) protection of equipment from ground faults
(c) discharging residual energies
(d) all of the above
Ans: d
113. If the time of operating of a relay for unity TMS is 10secs., the time of
operation for 0.5 TMS will be
(a) 20 secs.
(b) 5 secs.
c) 10 secs.
d) None of the above
Ans:b
16
114. A fault is more severe from the view point of RRRV if is a
a) Short line fault.
b) Medium length line fault.
c) Long line fault.
d) None of these.
Ans: a
115. A reactance relay is
a) Voltage restrained directional relay.
b) Directional restrained over-current relay.
c) Voltage restrained over-current relay.
d) None of the above.
Ans: (b)
Ans: (d)
117. Positive, negative and zero sequence impedances of a solidly grounded
system under steady state condition always follow the relations
a) Z4>Z2>Z0
b) Z2>Z4>Z0
c) Z0>Z4>Z2
d) None of the above
Ans: c
Ans: (b)
17
a) Chemical and ground rods only.
b) Chemical and counterpoise only.
c) Ground rod and counterpoise only.
d) Chemical, ground rods and counterpoise.
Ans: (c)
Ans: (d)
Ans: d
a. Magnitude
b. Frequency
c. Phase angle
d. All of these
Ans: d
124. On what factor does the operating speed of the relay depend upon?
18
a. Rate of flux built up
b. Armature core air gap
c. spring tension
d. All of these
Ans: d
125. What does the third part consist of?
a. Primary winding of a current CT which is connected in series with the line to be
protected.
b. Secondary of the CT and the operating coil.
c. Tripping circuit.
d. All of these.
Ans: c
126. Which component ensures the safety of the line from damage?
a. Relay
b. Circuit breaker
c. Bus bar
d. Current transformer
Ans: a
127. The tripping circuit is_
a. AC
b. DC
c. either AC or DC
d. None of these
Ans: c
128. Plug setting of a electromagnetic relay can be altered by varying
a. Number of ampere turns
b. Air gap of magnetic path
c. Adjustable back stop
d. None of these
Ans: a
129. the most efficient torque producing actuating structure for the
induction type relays is
a. Shaded pole structure
b. Watt hour meter structure
c. Induction cup structure
d. Single induction loop structure
Ans: c
130. If the power factor is zero, the active recovery voltage will be
(A) minimum
19
(B) 0.5
(C) 0.707
(D) Maximum.
Ans:d
131. Which of the following is not a part of the circuit breaker?
(A) Explosion pot
20
136. Which of the following relays is used on transformers?
21
(C) Resonance
(D) Any of the above.
Ans: d
142. The protection against over-voltage due to lightening is provided by
(A) Use of surge diverters
(B) Low tower footing resistance
(C) Use of overhead ground wires
(D) Any of the above.
Ans: d
143. Which of the following is a conducting medium for electric current ?
(A) Low temperature gas
(B) High temperature gas
(C) Dissociated gas
(D) Plasma.
Ans: d
144. In circuit-breakers the contact space is ionized by
(A) Thermal ionization of gas
(B) Thermal emission from surface of contacts
(C) Field emission from the surface of contacts
(D) Any of the above.
Ans: d
145. Which of the following are air-break switching devices ?
(A) Isolator
(B) Limit switch
(C) Earthling switch
(D) All of the above.
Ans:d
146. Which of the following statement about SF6 gas is incorrect?
(A) It is non-toxic gas
(B) It is non-inflammable
(C) It has density 5 times that of air at 200C
(D) It has dark yellow color.
Ans:d
147. SF6 gas is transported in
(A) Gas cylinders
22
(B) Liquid form in cylinders
(C) Solid form in boxes
(D) Air cylinders.
Ans: b
148. during arc extinction SF6 gas
(A) Decomposes into S and F ions
(B) Decomposes into SF4and SF2
(C) Gets oxidized
(D) Reduces to SF3.
Ans: b
149. Dielectric strength of SF6 is
(A) less than that of air at atmospheric pressure
(B) less than that of oil used in OCB
(C) more than that of oil used in OCB
(D) More at lower pressure and low at higher pressures.
Ans: b
150. Which of the following is the demerit of SF6 circuit breakers?
(A) Sealing problem of gas
(B) In flux of moisture in the gas system is dangerous
(C) Deterioration of quality of circuit breaker affects reliability of circuit breaker
(D) All of the above.
Ans: d