Link Layer Discovery Tool: Winpcap
Link Layer Discovery Tool: Winpcap
The Link Layer Discovery Tool is a command line application for MS Windows. It sends
requests to LLD server application which runs on all Integra series devices.
The application runs on the following version of Windows: Windows Vista, Windows 7,
Windows 8, and Windows 10.
The Link Layer Discovery Tool for Integra series can be downloaded in
https://saftehnika.com/en/downloads in “Tools” section. Login required.
1) Unzip the LLD.zip file you downloaded to a directory of your choice, for example,
C:\SAF\LLD\ .
2) The application is started via the command prompt (Start menuRuntype
“cmd”press ENTER). Command line console window should appear.
3) The default directory in the console is the current user directory. To change it, type:
cd <directory path>
For example: cd c:\saf\lld
4) Run the recovery tool by typing “lld” without quotes in the console prompt and press
ENTER.
After selecting, release the left button and click the mouse right button anywhere on
the console. The address should be copied.
Type “lld “ and paste the address by clicking the right button anywhere on the
console:
7) Use the MAC address of the device with the reset command to reset this specific
device. The MAC address can be copied the same way as the interface address.
8) The device is reset by using the required reset command with the recovery tool:
lld <interface> reset <MAC> <reset command>
Different reset options are available depending on the reset requirement. Reboot and
store options are also available. Store option saves the device current configuration
so it will be restored after system reboot. The commands are available in the reset
command list. Use the command after the MAC address of the device as shown in the
previous reset command example.
For example, to reset users and passwords on Integra device #1, use:
lld \DEVICE\NPF_{A67EA6B7-1686-4E98-BA19-2A7E5B205DCF} reset 0004A6813773 acc
Make sure the command is run within 3 minutes after Integra reboot (“RK1 fresh” must
be “true” in the console), otherwise error shown in the screenshot below error will
occur. The recovery tool will continue to retry the command.
Power down the Integra device and power it up again, the reset should be completed
soon.
9) Store changes by command (must be done within the time frame of 3 minutes after
boot) or by using WEB GUI (any time before the Integra device is powered off) “SAVE”
button.
For example,
lld \DEVICE\NPF_{A67EA6B7-1686-4E98-BA19-2A7E5B205DCF} reset 0004A6813773 store