Flujometro PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

s

Datasheet for
SITRANS F M MAG 5100 W

Ordering data: 7ME65204VC132AA2


C14

General
Manufacturer Siemens
Supplier Siemens
Brand name SITRANS F M MAG 5100 W
Type designation Sensor SITRANS FM MAG 5100 W
Net weight 61,1 kg
SITRANS F M - modularity for every application

Mode of operation and application


Measuring principle electromagnetic induction

Rated conditions
Pressure loss at flow rate (maximum) 25 mbar

Process medium
Medium temperature -10 °C...+70 °C

Pressure
Operating pressure, absolute (minimum) 0,03 bar

Environmental conditions
Ambient temperature during operation -40 °C...+70 °C

Degree of protection
IP rating IP67
NEMA rating NEMA 4X, NEMA 6

Electromagnetic compatibility EMC


Standard for EMC 2004/108/EC

Design
Mechanical design
Design of the housing separated version, sensor separated
Model of the measuring pipe Conical

...Process connection
Design flange
Standard EN 1092-1
Nominal size DN 250
Pressure rating PN 16
Model of the sealing surface Type A

...Material

....Process connection
Material carbon steel

....Housing
Material of the transducer Carbon steel
Coating of the sensor (outside) Two-component epoxy coating
Coating thickness (minimum) 150 µm

This is only an extract from the technical data. For more details, see the FI 01 catalog or the Industry Mall.
Creation date: 21.06.2019 Page 1 of 2
s
Datasheet for
SITRANS F M MAG 5100 W

Ordering data: 7ME65204VC132AA2


C14

....Sensor
Material of the measuring pipe stainless steel
Material number of measuring pipe according to DIN 1.4301
EN 10027-2
Material number of measuring pipe according to AISI 304
Material of the liner acrylonitril-butadiene-styrol-rubber (NBR/Perbunan/Buna N)

....Miscellaneous
Material of the electrodes nickel alloy (Hastelloy C276)
Material of the terminal box Fibre glass reinforced polyamide

...Dimensions
Installation length 450 mm

Electrical connections
Number of cable entries 2
Design of the cable entry 1/2" NPT

Certificates and approvals

472 Years
SN 29500
number of registered failures
Measuring device

The information provided in this data sheet contains descriptions or characteristics of performance which in case of actual use do not
always apply as described or which may change as a result of further development of the products. An obligation to provide the
respective characteristics shall only exist if expressly agreed in the terms of contract. Availability and technical specifications are subject
to change without notice.

This is only an extract from the technical data. For more details, see the FI 01 catalog or the Industry Mall.
Creation date: 21.06.2019 Page 2 of 2