V-Station™ Fingerprint Authentication Reader

Quick Start Instructions


Required items for Setup / Installation:
‰ This Quick Start Guide – Included
‰ A V-Station unit with mounting plate – Included
‰ CD containing application software, Installation and Operation Manuals – Included
‰ Security hex key needed to reveal the RJ-12 Aux port - Included
‰ An RJ-12 to DB-9 cable for programming the unit through the Aux port – Included
‰ Ethernet extension cable and inline coupler – Included
‰ DC power supply at 12.5-24V (UL-listed class II 12V @ 500mA recommended) – Not supplied

Optional items for Setup / Installation:


‰ Networking cable, Wiegand door controller, and Proximity Cards – Not Supplied
‰ RS-232/RS-485 Converter – Not Supplied
‰ External Wiegand Reader using a supported format – Not Supplied
‰ Computer running Windows 98, ME, NT 4.0, 2000, or XP – Not Supplied
‰ PC Ethernet NIC card and Ethernet cable (straight thru patch cable if connecting to a switch or hub, or a cross-over
cable if connecting directly to the PC Ethernet card) – Not Supplied*

Getting Started
Before installing the V-Station, please do the following:
‰ Read both the Operations and Installation Manual (Documents included on the CD-ROM)
‰ Read the V-Station Operator’s Manual for instructions on using the V-Station from the keypad
‰ Install the VeriAdmin Software on a PC or laptop computer equipped with available COMM/Ethernet ports.
‰ Configure Veri-Series units with correct baud rate, unique Network IDs, and IP address (if using Ethernet*)
‰ Become familiar with the V-Station operation, especially enrolling users using either the keypad or the PC software
‰ Read the MV-1200 Product Notes – Release Notification.pdf and Veri-Admin Release Announcement.pdf files on the
CD for the latest updates.

Note 1: CAUTION, the silicon sensor used in the Veri-Series product line is an electro-static sensitive device. The EGND
connection on the back of the V-Station must be connected to an earth ground for reliable operation. Installing a unit
without proper grounding will void the warranty. Refer to the installation manual for specific information.

Note 2: The V-Station differs from other Veri-Series products in that the pigtail wiring bundle in the back of the unit has
been replaced by Weidmuller connections and RJ-11/RJ-45 jacks. RS-232 communication is achieved by plugging into
the labeled RJ-11 jack while the RJ-45 jack provides RS-485 communication. Note that there is also a physical switch
which enables the RS-485 jack. V-Stations are shipped with this switch in the default position of “OFF” and must be
switched to “ON” if RS-485 communication is desired. All ports including the AUX port on the bottom of the unit are set to
a baud rate of 57600 from the factory.

Document #430-00120-05 © Copyright 2004 Bioscrypt Inc. Page 1


Setting Up the V-Station
‰ Install the VeriAdmin Software (included on CD) on a computer running Windows 98, ME, NT 4.0, 2000, or XP to
initially set up the V-Smart. You can install the template management software on your computer by running
“Setup.exe” found on the CD.
‰ Apply power to the V-Station through either the DC jack (12V DC) or the Weidmuller connectors in the back: connect
DC power (12.5-24 V) to the +(POS) terminal, and the power return (power ground) to the –(NEG) terminal.
‰ Connect the programming cable to the Aux port in the bottom of the unit.
‰ Run / Open the VeriAdmin software on your PC. Indicate which PC ports you would like to use, either COMM ports
or Ethernet* (or both).
‰ Now add units to the logical network tree diagram one at a time assigning unique network IDs. After establishing
communication and setting up your network, you may enroll or delete templates, broadcast templaets to other units,
store templates on the PC, and configure each reader as desired.
‰ Please refer to the Veri-Series Operations Guide for complete user instructions.

Additional Information
The biggest difference between the V-Station and the other Veri-Series products is obviously its keypad and LCD screen.
The product can be configured directly from the keypad and feedback is provided on-screen. Most operations which had
to be performed from the PC using VeriAdmin can now be performed directly from the keypad. Some of these functions
include:

9 Template management (enroll, edit, delete, etc)


9 Communications (ports, baud rates, network ID, Wiegand settings, etc)
9 Security (biometrics, global threshold, etc)
9 System control (time, date, transaction log, etc)

Not all functionality can be accessed via the keypad. Future firmware versions will add additional functionality but some
things will still need to be done via the PC using VeriAdmin software, such as transferring templates to additional units,
reading the transaction log, etc.

*Ethernet is supported in version 7.10 and later


Technical Support Contact Information:

Telephone: 866.304.7180 (toll free)


818.304.7180

Email: [email protected]
Web: www.bioscrypt.com

Address: Bioscrypt Inc


Technical Support Dept
5805 Sepulveda Blvd, Suite 750
Van Nuys, CA, 91411

Corporate & Canadian Office U.S. Office U.K. Office


5450 Explorer Drive, Suite 500 5805 Sepulveda Blvd., Suite 750 35 Jackson Court, Hazlemere
Mississauga, ON, Canada L4W 5M1 Van Nuys, CA 91411 High Wycombe, Buckinghamshire
T 905 624 7700 T 818 304 7150 England HP15 7TZ
F 905 624 7742 F 818 461-0843 T +44 (0) 1494 814 404
www.bioscrypt.com F +44 (0) 1494 815 513

Document #430-00120-05 © Copyright 2004 Bioscrypt Inc. Page 2

You might also like