KDC Nke-10123 Murata IsolationTransformers
KDC Nke-10123 Murata IsolationTransformers
KDC Nke-10123 Murata IsolationTransformers
SELECTION GUIDE
Isolation Capacitance
Output Current
Nominal Input
Efficiency
Voltage
Voltage
Output
MTTF1
Input
Package
Style
Order Code
Fully Encapsulated with Toroidal NKE0512SC 5 12 83 260 73 78 30 2910 73,523
Magnetics NKE0515SC 5 15 66 256 74 78 32 2211 71,725
NKE1205DC 12 5 200 117 68 72 35 3981 58,202
MTTF up to 2.4 Million hours NKE1209DC 12 9 111 107 72 78 50 3482 57,895
DIP
Custom Solutions Available NKE1212DC 12 12 83 105 73 79 57 1982 77,806
NKE1215DC 12 15 66 103 76 81 60 2122 56,404
No Electrolytic or Tantalum Capacitors
NKE1205SC 12 5 200 117 68 72 35 3981 58,202
NKE1209SC 12 9 111 107 72 78 50 3482 57,895
SIP
PRODUCT OVERVIEW NKE1212SC 12 12 83 105 73 79 57 1982 77,806
The NKE sub-miniature series of DC-DC Converters NKE1215SC 12 15 66 103 76 81 60 2122 56,404
is particularly suited to isolating and/or converting NKE0505SEC/NKE0505DEC offers higher efficiency than NKE0505SC/NKE0505DC but over a narrower operating temperature range.
DC power rails. A smaller package size, improved See temperature characteristics graph.
efficiency, lower output ripple and 3kVDC isolation
capability through state of the art packaging and INPUT CHARACTERISTICS
improved technology. The galvanic isolation allows Parameter Conditions Min. Typ. Max. Units
the device to be configured to provide an isolated Continuous operation, 3.3V input types 2.97 3.3 3.63
negative rail in systems where only positive rails Voltage range Continuous operation, 5V input types 4.5 5.0 5.5 V
exist. The wide temperature range guarantees Continuous operation, 12V input types 10.8 12.0 13.2
startup from –40°C and full 1 watt output at 85°C.
Reflected ripple current 3.3V input types 40 60 mA p-p
For full details go to 1. Calculated using MIL-HDBK-217 FN2 and Telcordia SR-332 calculation model with nominal input voltage at full load.
www.murata-ps.com/rohs All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
www.murata-ps.com/support
KDC_NKE.K09 Page 1 of 7
NKE Series
Isolated Sub-Miniature 1W Single Output DC-DC Converters
OUTPUT CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Rated Power TA=-40°C to 120°C, see derating graphs 1.0 W
Voltage Set Point Accuracy See tolerance envelope
Line regulation High VIN to low VIN 1.0 1.2 %/%
10% load to rated load, 3.3V output types & 0309 10 15
10% load to rated load, 5V output types 12 15
Load Regulation1 10% load to rated load, 9V output types 7.5 10 %
10% load to rated load, 12V output types 6.5 9.5
10% load to rated load, 15V output types 6.0 8.5
BW=DC to 20MHz, 3.3V output types & 0305, 0505SEC, 0505DEC 40 80
BW=DC to 20MHz, other 5V output types 77 100
Ripple and Noise BW=DC to 20MHz, 9V output types 43 90 mV p-p
BW=DC to 20MHz, 12V output types 35 65
BW=DC to 20MHz, 15V output types 32 55
ISOLATION CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Isolation test voltage Flash tested for 1 second 3000 VDC
Resistance Viso= 1000VDC 10 GΩ
GENERAL CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Switching frequency All output types 115 kHz
TEMPERATURE CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Specification All output types -40 85
Storage -50 130
°C
Case temperature rise above 0505D/S, 1205D/S 41
ambient All other output types 32
Cooling Free air convection
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,
applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions NKE series of DC-DC converters are all 100% production tested at their stated isolation voltage. This is 3000V DC for 1 second.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
The NKE series has been recognised by Underwriters Laboratory for functional insulation. Both input and output should normally be maintained within SELV limits i.e. less than
42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation sys-
tem. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the
barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry
according to safety standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materi-
als, construction and environment. While manufactured parts can withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any
material, including this enamel (typically polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of
tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from
specified test voltage.
SAFETY APPROVAL
The NKE series has been recognised by Underwriters Laboratory (UL) to UL 60950 for functional insulation in a maximum ambient temperature of 85ºC and/or case temperature
limit of 130ºC. Case temperature measured on the face opposite the pins. File number E151252 applies.
www.murata-ps.com/support
KDC_NKE.K09 Page 2 of 7
NKE Series
Isolated Sub-Miniature 1W Single Output DC-DC Converters
TOLERANCE ENVELOPES
3.3V output types. All other types.
+9% +10%
+5% Typical
Typical Load Line
+1% Load Lin +1% +2.5%
VNOM e VNOM
-2.5%
Output Voltage
Output Voltage
-15%
10 25 50 75 100 10 25 50 75 100
Output Load Current (%) Output Load Current (%)
The voltage tolerance envelope shows typical load regulation characteristics for this product series. The tolerance envelope is the maximum output voltage variation due to
changes in output loading.
This series is compatible with RoHS soldering systems with a peak wave solder temperature of 260°C for 10 seconds. The pin termination finish
on the SIP package type is Tin Plate, Hot Dipped over Matte Tin with Nickel Preplate. The DIP types are Matte Tin over Nickel Preplate. Both
types in this series are backward compatible with Sn/Pb soldering systems.
For further information, please visit www.murata-ps.com/rohs
www.murata-ps.com/support
KDC_NKE.K09 Page 3 of 7
NKE Series
Isolated Sub-Miniature 1W Single Output DC-DC Converters
APPLICATION NOTES
Minimum load
The minimum load to meet datasheet specification is 10% of the full rated load across the specified input voltage range. Lower than 10% minimum loading will result in
an increase in output voltage, which may rise to typically double the specified output voltage if the output load falls to less than 5%.
C1 1μF X7R multilayer ceramic capacitor, voltage rating to be a minimum of 3 times the output voltage of the DC-DC converter
10μF tantalum capacitor, voltage rating to be a minimum of 1.5 times the output voltage of the DC-DC converter with an ESR of less
C2
than 100mΩ at 100 kHz
C3 100nF multilayer ceramic capacitor, general purpose
R1 450Ω resistor, carbon film, ±1% tolerance
R2 50Ω BNC termination
T1 3T of the coax cable through a ferrite toroid
RLOAD Resistive load to the maximum power rating of the DC-DC converter. Connections should be made via twisted wires
Measured values are multiplied by 10 to obtain the specified values.
Differential Mode Noise Test Schematic
DC/DC Converter
OSCILLOSCOPE
C1 C2 C3 R1 T1 R2
+ + Y INPUT
- -
R LOAD
www.murata-ps.com/support
KDC_NKE.K09 Page 4 of 7
NKE Series
Isolated Sub-Miniature 1W Single Output DC-DC Converters
By using the values of inductance and capacitance stated, the output ripple at the rated load is lowered to 5mV p-p max.
Component selection
Capacitor: It is required that the ESR (Equivalent Series Resistance) should be as low as possible, ceramic types are recommended.
The voltage rating should be at least twice (except for 15V output), the rated output voltage of the DC-DC converter.
Inductor: The rated current of the inductor should not be less than that of the output of the DC-DC converter. At the rated current, the DC resistance of the inductor
should be such that the voltage drop across the inductor is <2% of the rated voltage of the DC-DC converter. The SRF (Self Resonant Frequency) should be
>20MHz.
L
Power
DC
C Load
Source
DC
Inductor Capacitor
L, μH SMD Through Hole C, μF
NKE0303xC 10 82103C 11R103C 4.7μF
NKE0305xC 47 82473C 11R473C 4.7μF
NKE0309xC 47 82473C 11R473C 1μF
NKE0503xC 10 82103C 11R103C 4.7μF
NKE0505xC 47 82473C 11R473C 4.7μF
NKE0505xEC 47 82473C 11R473C 4.7μF
NKE0509SC 47 82473C 11R473C 1μF
NKE0512xC 68 82683C 11R683C 0.68μF
NKE0515xC 100 82104C 11R104C 2.2μF
NKE1205xC 47 82473C 11R473C 4.7μF
NKE1209xC 47 82473C 11R473C 1μF
NKE1212xC 68 82683C 11R683C 0.47μF
NKE1215xC 100 82104C 11R104C 2.2μF
www.murata-ps.com/support
KDC_NKE.K09 Page 5 of 7
NKE Series
Isolated Sub-Miniature 1W Single Output DC-DC Converters
PACKAGE SPECIFICATIONS
2.54 [0.100]
0.50±0.05 [0.020±0.002]
www.murata-ps.com/support
KDC_NKE.K09 Page 6 of 7
NKE Series
Isolated Sub-Miniature 1W Single Output DC-DC Converters
x4 HOLES
Ø 1.15
1.00 [
Ø 0.045
0.039 ]
2.54 [0.100]
9.3 [0.366]
14.8 [0.583]
5.40 (0.213)
5.00 (0.197)
0.60±0.15 (0.0236±0.006)
Unless otherwise specified all dimensions in mm [inches] ±0.55mm [0.022].
Tube length (8 Pin DIP) : 520mm ± 2mm (20.47). 4.45 [0.175]
Tube length (4 Pin SIP) : 525mm ±2mm (20.67). Tube Quantity : 40
www.murata-ps.com/support
KDC_NKE.K09 Page 7 of 7
Mouser Electronics
Authorized Distributor
Murata:
NKE0305SC NKE0305DC NKE0303DC NKE0303SC NKE0509DC NKE0509SC NKE1205SC NKE1205DC
NKE1209DC NKE1209SC NKE0503SC NKE0503DC NKE0505SC NKE0515DC NKE0515SC NKE1215DC
NKE1215SC NKE0505SEC NKE0512SC NKE0512DC NKE1212DC NKE1212SC NKE0309DC NKE0309SC
NKE0505DEC