Sensors Worldwide: BTL5-P/I/K/L/M - M/U - P-S 32/KA - Micropulse Linear Transducer Digital Output / Profile Housing
Sensors Worldwide: BTL5-P/I/K/L/M - M/U - P-S 32/KA - Micropulse Linear Transducer Digital Output / Profile Housing
Sensors Worldwide: BTL5-P/I/K/L/M - M/U - P-S 32/KA - Micropulse Linear Transducer Digital Output / Profile Housing
Generation 5
Output Type
Compact, Explosion-proof
I = Differential start/stop with tri-state bolt-in Rod Style
K = Differential stop - leading edge active
L = Differential pulse-width modulated Rod Style
M = Differential start/stop - leading edge active
N = Single ended start/stop - leading edge active
P = Differential start/stop - trailing edge active
Supply Voltage
1 = 24 Vdc ±20%
2 = ±15 Vdc ±2%
Connection Type
Micropulse Transducer
WWW.BALLUFF.COM • 1-800-543-8390
Downloaded from www.Manualslib.com manuals search engine
BTL5-P/I/K/L/M_-M/U_ _ _ _-P-S32/KA_ _
Micropulse Linear Transducer
Digital Output / Profile Housing
3 Installation (cont.)
NL
Nominal stroke
max. permissible
55 tightening torque 2 Nm
45
E 21 E C
28
Ø 4.2
20
15
D
61 +10
1
Fig. 3-2: BTL5-P-3800-2 magnet Fig. 3-3: BTL5-P-5500-2 magnet Fig. 3-4: BTL5-P-4500-1
electromagnet (24 V/100 mA)
1-800-543-8390 • WWW.BALLUFF.COM
Downloaded from www.Manualslib.com manuals search engine
BTL5-P/I/K/L/M_-M/U_ _ _ _-P-S32/KA_ _
Micropulse Linear Transducer
Digital Output / Profile Housing
3 Installation (cont.)
NL
Fig. 3-5: Dimensional drawing (BTL5...P-KA transducer with captive magnet BTL5-F-2814-1S)
BTL5-M-2814-1S: X = 48.5 Y = 57
Fig. 3-6: BTL5-F-2814-1S magnet BTL5-N-2814-1S: X = 51 Y = 59.5
Fig. 3-7: BTL5-M/N-2814-1S magnet
WWW.BALLUFF.COM • 1-800-543-8390
Downloaded from www.Manualslib.com manuals search engine
BTL5-P/I/K/L/M_-M/U_ _ _ _-P-S32/KA_ _
Micropulse Linear Transducer
Digital Output / Profile Housing
4 Wiring
8 WH -15 V
0117a027
Note the following When routing the cable between straignt right-angle
when making BKS-S 32M-00 BKS-S 33M-00
the transducer, controller and
Cable entry
electrical connec- power supply, avoid proximity to
(PG 9 fitting)
tions: high voltage lines to prevent noise
coupling.
System and control cabinet
must be at the same Especially critical is inductive
ground potential. noise caused by AC harmonics
(e.g. from phase-control devices),
To ensure the electromagnetic against which the cable shield
compatibility (EMC) which provides only limited protection.
Balluff warrants with the CE
Mark, the following instruc- Cable length max. 500 m ;
tions must be strictly Ø 6 to 8 mm.
followed. Fig. 4-1: Connector (optional)
High noise immunity on the line
BTL transducer and the between the transducer and
processor/control must be processor is provided by the
connected using differential line drivers used for
shielded cable. the RS 485/422 interface. The
differential signal is carried to the BKS connector,
Shielding: Copper filament processor, which makes it
braided, 80% coverage. view towards
available as analog or digital
information for solder side of
The shield must be tied to the female BKS-S
connector housing in the further processing.
32M-00 or BKS-S
BKS connector (Fig. 4-1); see
33M-00
instructions accompanying
the connector.
Fig. 4-2: Pin assignments BKS,
In the cable version the cable connector type BTL
shield is connected to the
housing in the PG fitting.
The cable shield must be
grounded on the control side,
i.e., connected to the
protection ground.
Pin assignments can be
found in Table 4-1. Connec-
tions on the controller side
may vary according to the
controller and configuration
used.
1-800-543-8390 • WWW.BALLUFF.COM
Downloaded from www.Manualslib.com manuals search engine
BTL5-P/I/K/L/M_-M/U_ _ _ _-P-S32/KA_ _
Micropulse Linear Transducer
Digital Output / Profile Housing
4 Wiring (cont.)
INIT YE
START/STOP GY
INIT PK
BTL5-P1...KA_ _
START/STOP GN
processor or
GND BU
controller
+24 V BN
5 Startup
5.1 Check connections 5.3 Check output values 5.5 Fault conditions
Although the connections are After replacing or repairing a When there is evidence that the
polarity reversal protected, transducer, it is advisable to verify transducer system is not
components can be damaged the values for the start and end operating properly, it should be
by improper connections and position of the magnet in manual taken out of service and
overvoltage. Before you apply mode. If values other* than those guarded against unauthor-
power, check the connec- present before the replacement or ized use.
tions carefully. repair are found, a correction should
be made.
5.6 Noise elimination
5.2 Turning on the system * Transducers are subject to
modification or manufacturing Any difference in potential -
Note that the system may tolerances. current flow - through the cable
execute uncontrolled move- shield should be avoided.
ments when first turned on or Therefore:
when the transducer is part of a 5.4 Check functionality
closed-loop system whose – Use the isolation bushings,
parameters have not yet been The functionality of the transducer and
set. Therefore make sure that system and all its associated – Make sure the control
no hazards could result from components should be regularly cabinet and the system in
these situations. checked and recorded. which the BTL5 is contained
are at the same
ground potential.
Start Stop Start Stop Start Stop Start Stop Stop Gate
Single Ended (Trailing Edge (Leading Edge (RS-485 (Leading Edge (Pulse-width-
Active) Active) Multiplex) Active) Modulated)
WWW.BALLUFF.COM • 1-800-543-8390
Downloaded from www.Manualslib.com manuals search engine
BTL5-P/I/K/L/M_-M/U_ _ _ _-P-S32/KA_ _
Micropulse Linear Transducer
Digital Output / Profile Housing
7 Technical Data
The following are typical values at DC 24 V and 25 °C. Fully operational after power-up, with full accuracy after
warm-up. Values are with BTL5-P-3800-2, BTL5-P-4500-1 or BTL5-P-5500-2 magnet held at a constant
offset from the transducer or with captive magnet BTL5-F/M/N-2814-1S (see magnet section for exceptions):
1-800-543-8390 • WWW.BALLUFF.COM
Downloaded from www.Manualslib.com manuals search engine
BTL5-P/I/K/L/M_-M/U_ _ _ _-P-S32/KA_ _
Micropulse Linear Transducer
Digital Output / Profile Housing
NL
Nominal stroke
15
D
61 +10
1
Fig. 3-2: BTL5-P-3800-2 magnet Fig. 3-3: BTL5-P-5500-2 magnet Fig. 3-4: BTL5-P-4500-1
electromagnet (24 V/100 mA)
Ball joint "B" Black, round
marking Mechanically joined to M5 Max. angle offset
DIN 71805, Max. parallel offset
stud using 2 nuts
rotates horizontally
BTL5-M-2814-1S: X = 48.5 Y = 57
BTL5-N-2814-1S: X = 51 Y = 59.5
WWW.BALLUFF.COM • 1-800-543-8390
Downloaded from www.Manualslib.com manuals search engine
www.balluff.com
USA
North American Headquarters
Balluff Inc.
8125 Holton Drive
Florence, KY 41042
Electromechanical Identification
Phone: (859) 727-2200 Sensors Systems
Toll-free: 1-800-543-8390
Fax: (859) 727-4823
Web: www.balluff.com