Installation Instruction BCB8005 Power Supply: Building Technologies

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Building Technologies

Installation Instruction
BCB8005 Power Supply
Figure 1
BCB8005

Introduction BCB8005 power supply is a high current power supply that provides the BC8002A
system with primary regulated 24VDC. It is rated at 6A and has a built-in charger
that is capable of charging 40AH batteries. It has a transfer circuit that allows the
BCB8005 to switch the system power to stand-by batteries during loss or reduction
of the AC power.

The controller monitors the status of the BCB8005 (AC fault, Ground fault, charger
circuit fault, battery fault).

Features  Universal AC power input 120VAC/60Hz, 240VAC/50Hz


 Alternative AC power switch
 Two power outputs of 6A@24VDC, 3A@5VDC in total
 AC fuse capacity: 5.0A; Battery fuse capacity: 10.0A

Terminals

Figure 2
Terminals on the BCB8005

L/N/GND: AC input connector from external power supply. These connectors


are non-power limited.
Input voltages: 120VAC/60Hz, 240VAC/50Hz
120Vac~240Vac: AC input switch for 120V or 240V.
24V+Ⅰ/24V-Ⅰ: 24VDC output terminals.

Siemens Building Technologies Doc.No: A6V10255819 Revision: a Page:1/1


Issue Date: 2009/06
24V+Ⅱ/24V-Ⅱ: 24VDC output terminals.
24V+Ⅲ/24V-Ⅲ: 24VDC output terminals.
5V+/5V-: Not connected.
PPF: Main power fault. When main power fault happens, a fault event will be
reported on fault window.
BF: Battery fault. When battery fault happens, a fault event will be reported on
fault window.
CCF: Charge circuit fault. When charge circuit fault happens, a fault event will
be reported on fault window.
CG: Ground of PPF, BF and CCF.
BAT+/BAT-: Connects the back-up battery to the power supply. These
connectors are non-power limited.
AC Fuse: To change AC fuse (5.0A).
BAT. Fuse: To change battery fuse (10.0A).

Installation Disconnect battery and AC prior to working on equipment.


1. Place the BCB8005 against the back of BC8002A
2. Align the mounting screw holes of BCB8005 with the threaded positions as
shown in figure 3.
3. Install four M4×8mm screws and tighten them.
4. Connect cables to terminals as shown in figure 2.

Threaded Positions

Figure 3
Location of BCB8005 in BC8002A

Siemens Building Technologies Page: 2/4


Technical Specification

Items Standard value


Input voltage 120/240 VAC
Input frequency 60/50 Hz
Rated input current 1.9A@120VAC, 890mA@240VAC
Output Max. 6A@24VDC
Max. 3A@5VDC
Operating temperature -20...+55℃
Storage temperature -45...+85℃
Humidity ≤95%(40±2℃)

Battery
Maximum battery circuit current Charging: 3.1A
Discharging:8.0A
Capacity Sealed Leaded Acid
12VDC,40Ah×2
Expected battery standby 24 Hours and 5 Minutes alarm
operational times
Dimension(mm) 197×165×170(L×W×H)

Power Supply
Bat- Bat+

- + - +

Battery Battery

Figure 4
Battery and AC power connection diagram

Siemens Building Technologies Page: 3/4


Order Information
Type Description Stock Code
BCB8005 BC8002A Power Supply 100790553

Power supply load calculation form


No. Type Description Quantity Quiescent Max. Total
current(mA) current(mA) Quiescent
current(mA)
1. BDS031A Addressable heat detector 0.8 1.0
2. BDS051A Addressable smoke detector 0.8 1.0
3. BDS121A Manual signaling box 0.8 1.0
4. BC8002A Control unit 660.0/120V 1283.0/120V
330.0/240V 642.0/240V
5. BDS132A Input module 1.0 3.0
6. BDS221A Output module 1.0 3.0
7. BDS152 Isolator 0 0.5
8. BDS161 Collective input module 4.0 16.0
9. ZH-MC * Multitone horn strobe(red) 0 200.0
10. DSC Dual sync control module 0 55.0
11. P2R8 ** SpectrAlert horn/strobe 0 245.0
12. MDL Sync-Circuit module 0 12.0

NOTE * = Max number of 10 devices utilized by BC8002A.


NOTE ** = Max number of 12 devices utilized by BC8002A.