Series: C80/C89 C70/C74
Series: C80/C89 C70/C74
Series: C80/C89 C70/C74
C70/C74
OVERVIEW:
Valves designed for extreme low
temperatures incorporating
extended bonnets to ensure
stem sealing integrity.
An extended bonnet
and stem that distances
the stem seals from the
cryogenic fluids and
prevents them from seizing.
2 Smith-Cooper International • Toll Free (800) 766-0076 • Fax (323) 890-4456 • www.smithcooper.com
SERIES C80/C89 & C70/C74 CRYOGENIC BALL VALVE
Extension Bonnet
The cryogenic extension bonnet
is securely bolted to the valve
mounting pad.
Stem Sealing
Increased stem sealing area for
severe service assures bubble
tight leakage in the toughest high
cycle applications.
Uni-Directional
An alignment pin between the
ball and stem assures proper
orientation of the ball.
1500
1200
TFM®
1100
1000
900
PCTFE
Pressure (PSIG)
NOVA
800
600
PTFE
Series C703
Series C743
500
400
300
Class 150
200 Series C701
Series C741
100 Thermal
Fluid
0
-450 -400 -350 -300 -250 -200 -150 -100 -50 0 50 100 150 200 250 300 350 400 450 500 550 600
Temperature (°F)
Note:
The maximum pressure/temperature ratings of the valve assemblies are limited to lowest of the body or seat material fitted.
The valve body ratings are based on ASME B16.34 rating for materials.
The graphs are based on laboratory testing and our experience in field.
The seat ratings depend on the material, design, application and function.
5 Smith-Cooper International • Toll Free (800) 766-0076 • Fax (323) 890-4456 • www.smithcooper.com
SERIES C80/C89 & C70/C74 CRYOGENIC BALL VALVE
19
10
18
CRYOGENIC EXTENSION
6
27** Anti-Static Ball 300 Series Stainless Steel 1
7 28** Anti-Static Spring Hard Drawn Stainless Steel 1
4
3
4
5
2
6 Smith-Cooper International • Toll Free (800) 766-0076 • Fax (323) 890-4456 • www.smithcooper.com
SERIES C80/C89 & C70/C74 CRYOGENIC BALL VALVE
17 6 Seat Ring (80 series only) 316 Stainless Steel ASTM A351 CF8M 1
11 29 7 Body Bolt/Stud A193 Gr. B8 4 - 16
30 16
15
8 Body Nut 300 Series Stainless Steel 4 - 16
14 CRYOGENIC EXTENSION
7 Smith-Cooper International • Toll Free (800) 766-0076 • Fax (323) 890-4456 • www.smithcooper.com
SERIES C80/C89 & C70/C74 CRYOGENIC BALL VALVE
Dimensions for
Actuator Mounting
STEM
HEIGHT
STEM
HEIGHT
Standard Full
Port Port
TE/SW Ext BW
BW Full Port
Dimensions (Inches)
C80 C89 ØPORT A A C D E F G H K (Thread) M ØP (PCD) ØR S ØT X Y
½" ¼", ⅜" 0.44 2.91 - 1.27 12.30 6.42 13.62 11.57 1.81 M5-P0.8 0.264 F04 (1.65) 1.18 0.051 0.394 0.74 0.33
¾" ½" 0.56 3.07 - 1.42 12.44 6.42 13.78 11.73 1.95 M5-P0.8 0.264 F04 (1.65) 1.18 0.051 0.394 0.74 0.33
1" ¾" 0.81 3.72 13.10 1.74 12.91 7.28 14.17 12.09 2.39 M6-P1.0 0.343 F05 (1.97) 1.38 0.059 0.472 0.83 0.37
1¼" 1" 1.00 4.25 13.25 1.91 13.07 7.28 14.33 12.24 2.85 M6-P1.0 0.343 F05 (1.97) 1.38 0.059 0.472 0.83 0.37
1½" 1¼" 1.24 4.57 13.61 2.40 14.37 9.45 15.83 12.99 3.15 M8-P1.25 0.512 F07 (2.76) 2.17 0.059 0.709 1.41 0.54
2" 1½" 1.50 5.04 13.90 2.56 14.57 9.45 15.98 13.15 3.78 M8-P1.25 0.512 F07 (2.76) 2.17 0.059 0.709 1.41 0.54
2½" 2" 2.00 6.34 14.21 3.58 16.02 15.75 17.17 14.33 4.92 M10-P1.5 0.630 F10 (4.02) - - 0.886 1.70 0.59
3" 2½" 2.50 6.65 14.87 3.98 16.65 23.62 18.11 14.72 6.30 M10-P1.5 0.807 F10 (4.02) - - 1.024 1.93 0.68
4" 3" 3.25 8.43 - 4.57 17.20 23.62 18.70 15.35 7.99 M10-P1.5 0.807 F10 (4.02) - - 1.024 1.93 0.68
The dimensions above are for informational purposes only. Please refer to Sharpe® Valves if you need dimensions for construction.
8 Smith-Cooper International • Toll Free (800) 766-0076 • Fax (323) 890-4456 • www.smithcooper.com
SERIES C80/C89 & C70/C74 CRYOGENIC BALL VALVE
Dimensions for
Actuator Mounting
Dimensions (Inches)
Class Class Class Class Class Class
Series 150 300 150 300 150 300
C70 ØPORT A A B B C D E F G ØH ØH K M ØP ØR S ØT X Y
(Thread) (PCD)
½" 0.56 4.25 5.50 1.96 2.36 1.41 12.44 6.42 13.88 11.71 3.50 3.75 M5-P0.8 0.264 F04 (1.65) 1.18 0.051 0.394 0.74 0.33
¾" 0.81 4.62 6.00 2.13 2.52 1.53 12.56 6.42 14.00 11.81 3.88 4.61 M5-P0.9 0.264 F04 (1.65) 1.18 0.051 0.394 0.74 0.33
1" 1.00 5.00 6.50 2.13 2.72 1.93 13.07 7.28 14.37 12.24 4.25 4.88 M6-P1.0 0.343 F05 (1.97) 1.38 0.059 0.472 0.83 0.33
1½" 1.50 6.50 7.50 2.97 3.21 2.56 14.53 9.45 15.98 13.11 5.04 6.12 M8-P1.25 0.512 F07 (2.07) 2.17 0.059 0.709 1.41 0.33
2" 2.00 7.00 8.50 3.25 3.37 2.94 14.90 9.45 16.42 13.49 6.00 6.50 M8-P1.26 0.512 F07 (2.07) 2.17 0.059 0.709 1.41 0.50
2½" 2.50 7.50 9.50 3.58 4.00 3.98 16.65 15.75 18.11 14.72 7.01 7.52 M10-P1.5 0.807 F10 (4.02) - - 1.024 1.93 0.59
3" 2.99 8.00 11.12 3.83 4.20 4.25 16.93 23.62 18.39 15.00 7.52 8.27 M10-P1.5 0.807 F10 (4.02) - - 1.024 1.93 0.68
4" 3.94 9.00 12.00 4.61 5.06 4.90 17.56 23.62 19.03 15.65 9.02 10.00 M10-P1.5 0.807 F10 (4.02) - - 1.024 1.93 0.68
The dimensions above are for informational purposes only. Please refer to Sharpe® Valves if you need dimensions for construction.
9 Smith-Cooper International • Toll Free (800) 766-0076 • Fax (323) 890-4456 • www.smithcooper.com
SERIES C80/C89 & C70/C74 CRYOGENIC BALL VALVE
Dimensions for
Actuator Mounting
Dimensions for
Actuator Mounting
Dimensions (Inches)
Class Class Class Class Class Class
Series 150 300 150 300 150 300
C74 ØPORT A A B B C D E F G ØH ØH K M ØP ØR S ØT X Y
(Thread) (PCD)
1" 0.81 5.00 6.50 2.70 4.20 1.53 12.56 6.40 14.02 11.81 4.25 4.88 M5-P0.8 0.264 F04 1.18 0.051 0.394 0.74 0.37
(1.65)
F07
1½" 1.24 6.50 7.50 3.35 4.34 2.40 14.37 9.45 15.83 12.99 5.04 6.12 M8-P1.25 0.512 (2.07) 2.17 0.059 0.709 1.41 0.33
F07
2" 1.50 7.00 8.50 3.86 5.35 2.56 14.53 9.45 15.98 12.87 6.00 6.50 M8-P1.25 0.512 (2.07) 2.17 0.059 0.709 1.41 0.54
F10
3" 2.50 8.00 11.12 3.82 6.93 3.98 16.65 23.62 18.07 14.72 7.52 8.27 M10-P1.5 0.807 (4.02) - - 1.024 1.93 0.68
F10
4" 3.25 9.00 12.00 4.80 7.80 4.59 17.24 23.62 18.66 15.31 9.02 10.00 M10-P1.5 0.807 (4.02) - - 1.024 1.93 0.68
The dimensions above are for informational purposes only. Please refer to Sharpe® Valves if you need dimensions for construction.
10 Smith-Cooper International • Toll Free (800) 766-0076 • Fax (323) 890-4456 • www.smithcooper.com
SERIES C80/C89 & C70/C74 CRYOGENIC BALL VALVE
Technical Information
Applicable Standards
VALVE SIZE Body Wall Thickness ASME B16.34
APPROX.
Cv WEIGHT (lbs.) SW & Threaded Ends ASME B16.11
C80 C89 Butt-Weld Ends ASME B16.25
½" ¼",¾" 8 4 Basic Design ASME B16.34, BS 6364
¾" ½" 12 4 Pressure Test API 598, MSS-SP 72
1" ¾" 32 6 Mounting Dimensions ISO 5211
1¼" 1" 46 8 Marking MSS-SP 25
1½" 1¼" 80 13
2" 1½" 120 16
2½" 2" 240 33
3" 2½" 350 38
4" 3" 720 59
11 Smith-Cooper International • Toll Free (800) 766-0076 • Fax (323) 890-4456 • www.smithcooper.com
SERIES C80/C89 & C70/C74 CRYOGENIC BALL VALVE
Size Valve Series Body & Ends Seat Body Seal Stem Packing Ends
C70 C74 C70 Full Port 6 316 Stainless Steel K PCTFE (Kel-F®) I Graphite- M TFM® 1 Class 150 Flanged RF
½" - C74 Reduced Port M TFM® Impregnated 1F Class 150 Flanged FF
N Nova
¾" -
Ball & Stem N Nova T PTFE 3 Class 300 Flanged RF
6 316 Stainless Steel
1" 1" Class R RTFE 3F Class 300 Flanged FF
1½" 1½" 1 150 T PTFE
2" 2" 3 300 Options
2½" - HC High Cycle Stem*
3" 3" NS Anti-Static*
4" 4" TP Tamper Proof
Locking Device
Other materials / options available please
contact us with your unique requirement. * Price on Application
12 Smith-Cooper International • Toll Free (800) 766-0076 • Fax (323) 890-4456 • www.smithcooper.com