0% found this document useful (0 votes)
264 views2 pages

Square Wave and Pulse Generator

The document discusses square wave and pulse generators. It explains that square wave generators produce an output voltage with equal on and off periods, resulting in a duty cycle of 0.5 or 50% regardless of frequency. Pulse generators can vary their duty cycle, which is defined as the ratio of average pulse value to peak value over one cycle or the ratio of pulse width to period. Laboratory-type square wave and pulse generators contain two current sources, a ramp capacitor, and Schmitt trigger circuit that charge and discharge the capacitor to generate output waveforms, with symmetry control determining duty cycle.

Uploaded by

Kavita Kamerikar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
264 views2 pages

Square Wave and Pulse Generator

The document discusses square wave and pulse generators. It explains that square wave generators produce an output voltage with equal on and off periods, resulting in a duty cycle of 0.5 or 50% regardless of frequency. Pulse generators can vary their duty cycle, which is defined as the ratio of average pulse value to peak value over one cycle or the ratio of pulse width to period. Laboratory-type square wave and pulse generators contain two current sources, a ramp capacitor, and Schmitt trigger circuit that charge and discharge the capacitor to generate output waveforms, with symmetry control determining duty cycle.

Uploaded by

Kavita Kamerikar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

SQUARE WAVE AND PULSE GENERATOR

The square wave generator and pulse generator are generally used as measuring
devices in combination with the oscilloscope. The basic difference between square wave
generator and pulse generator is in the duty cycle. The duty cycle is defined as the ratio of
average value of a pulse over one cycle to the peak value. It is also defined as ratio of the
pulse width to the period of one cycle.

The average value is half of peak value. Both the average value and peak value are
inversely proportional to time duration. The average value of a pulse is given as,
1
Average value = 1/2 Peak value
Duty cycle of square wave = 0.5
Thus square wave generator produces an output voltage with equal ON and OFF
periods as duty cycle is 0.5 or 50% as the frequency of oscillation is varied. Then we can
state that irrespective of the frequency of operation, the positive and negative half cycles
extend over half of the total period

Laboratory type square wave and pulse generator:


The circuit consists of two current sourcesJ a ramp capacitor, and schmitt trigger circuit
as well as curr~wit~ht!!g 9,rcuit. The two current sources provide a constan Cllr.ITn~to
aJamp c:apaci tor for charging and discharging. The ratio of tnese charging and discharging
current is' determined by setting of symmetry control. The symmetry control determines
duty cycle of output waveform. In the current source, an appropriate control voltage is
applied to current control transistors which controls the frequency i.e. sum of two currents.
The multiplier switch provides decade switching control output frequency. While
frequency dial provi.des continuous vernier control of output frequency.
The block diagram of laboratory type square wave and pulse generator is as shown in fig:

Source : http://elearningatria.files.wordpress.com/2013/10/ece-iii-electronic-instrumentation-10it35-
notes.pdf