4.chint Contactor (NXC)
4.chint Contactor (NXC)
Overview
Applicable scop
The new NXC AC contactors feature a novel appearance and a compact structure. They are
mainly used for frequent starts and control of AC motors as well as remote circuit making /breaking.
They can also be combined with appropriate thermal overload relays to form electromagnetic
starters.
Compliant standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1.
Parameters
Installation class Ⅲ
Pollution degree 3
Certification mark CE
The relative humidity should not exceed 50% at the upper temperature limit
of +70℃.
Atmospheric conditions A higher relative humidity is allowed at a lower temperature, e.g. 90% at +20℃.
Special precautions should be taken against occasional condensation due to
humidity variations.
The angle between the installation surface and the vertical surface should
Installation conditions
not exceed ±5°.
Description
NXC AC contactor
06, 09, 12, 16, /N: Reversible contactor 24V, 36V, 48V, 110V, 127V, 50Hz,
18, 22, 25, 32, 220V, 230V,240V, 380V, 60Hz,
38, 40, 50, 65, 415V, 440V, 480V, 660V 50/60Hz
75, 85, 100, (AC: 06A~225A;
120, 160, 185, AC/DC: 265A~630A)
225, 265, 330,
400, 500, 630
Note: 06A-100A products contain one NO auxiliary contact and one NC auxiliary contact. 120A-630A products contain two NO auxiliary contacts
and two NC auxiliary contacts.
Auxiliary
Model Rated current Coil form Special function Coil voltage Frequency
contact
4P main contact
Model Rated current Coil form Special function Coil voltage Frequency
combination
Model example: NXC-12 240V 50Hz represents an AC contactor under AC-3 utilization category that provides a rated current of 12A at a main circuit
voltage of 380V/400V/415V. Each contactor body contains one NO auxiliary contact and one NC auxiliary contact. The coil control voltage and
frequency are 240V AC and 50Hz respectively.
Motor power kW Maximum operation current A Number of contacts contained in the contactor body
Contactor model
220V/230V/240V 380V/400V 660V/690V (AC-3 380V/400V) NO NC
2.2 4 4 9 1 0 NXC-09M10
2.2 4 4 9 0 1 NXC-09M01
3 5.5 4 12 1 0 NXC-12M10
3 5.5 4 12 0 1 NXC-12M01
4 7.5 10 18 1 1 NXC-18
5.5 11 11 22 1 1 NXC-22
5.5 11 15 25 1 1 NXC-25
11 18.5 30 40 1 1 NXC-40
15 22 37 50 1 1 NXC-50
18.5 30 37 65 1 1 NXC-65
22 37 37 75 1 1 NXC-75
22 37 45 85 1 1 NXC-85
25 45 45 100 1 1 NXC-100
37 55 80 120 2 2 NXC-120
NXC-06M~12M
NXC-06~100
NXC-120~225
NXC-265~630
Accessories
Accessory diagrams
NXC AC contactor
AX-3C NXC
side-attached AC contactor
auxiliary contactor F5 delay head
Accessory description
AX - 3X 11 AX - 3M 11 AX - 3C / 11 B
B: Expanded model,
Applicable to 11, 20, 02 Applicable to 11, 20, 02 used for 265A~630A
6A-630A 22, 13, 31 NXC-06M ~12M 22, 13, 31 AC contactor
AC contactor 04, 40 AC contactor 04, 40 11
product product
AXC 1 F5 T 4
Dust cover 1: Used for NXC-06~22, NXC-120~630 Air delay Delay type Delay range
2: Used for NXC-25~38 head model
3: Used for NXC-40~65
4: Used for NXC-75~100
T: Power-on 0: 0.1~3s
delay 2: 0.1~30s
D: Power-off 4: 10~180s
delay