Diff

The document lists parameters for a V1000 control system, including over 50 different settings related to control methods, speeds, frequencies, voltages, motor properties, communication settings, protections, and more. The parameters are organized in a table with columns for number, name, setting value, unit, and default setting. Ranges or options are shown for some parameters, and most can be set differently than the default.

Uploaded by

Maria Tzagaraki
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
47 views1 page

Diff

The document lists parameters for a V1000 control system, including over 50 different settings related to control methods, speeds, frequencies, voltages, motor properties, communication settings, protections, and more. The parameters are organized in a table with columns for number, name, setting value, unit, and default setting. Ranges or options are shown for some parameters, and most can be set differently than the default.

Uploaded by

Maria Tzagaraki
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Parameters

Printing Date : December 20, 2018


V1000 File Name : nees_rithmiseisdwp.dwp

Parameters List

No. Name Setting Value Unit Default Setting


A1-02 Control method 2- 0
b3-02 Speed search current 150 % 100
C1-01 Acceleration time 1 2.0 sec 10.0
C1-02 Deceleration time 1 0.5 sec 10.0
C2-04 S-curve deceleration at end 0.20 sec 0.00
C4-02 Torque compensation time 200 ms 20
C6-02 Carrier frequency selection 0001 - 0003
d1-01 Frequency reference 1 6.00 Hz 0.00
d3-04 Jump frequency width 0.0 Hz 1.0
E1-04 Max. output frequency 120.0 Hz 50.0
E1-07 Mid output frequency 2.5 Hz 3.0
E1-08 Mid output frequency voltage 22.0 VAC 28.8
E1-09 Min. output frequency 0.8 Hz 0.5
E1-10 Min. output frequency voltage 10.0 VAC 6.0
E2-05 Motor line-to-line resistance 10.088 Ohm 10.100
H1-03 Terminal S3 function selection 0009 - 0024
H3-02 Terminal A1 Function Selection 000B - 0000
H3-10 Terminal A2 Function Selection 000F - 0000
H3-13 Filter Avg time 0.10 sec 0.03
H5-01 Station address 0000 - 001F
H5-03 Communication parity selection 1- 0
H5-04 Serial fault selection 1- 3
H5-06 Send wait time 10 ms 5
H6-02 Pulse train input scaling 25000 Hz 1440
L1-02 Motor protection time constant 5.0 min 1.0
L2-01 Momentary power loss detection 1- 0
L5-01 Number of auto restart attempts 2 time(s) 0
L6-02 Torque detection level 1 160 % 150
L6-05 Torque detection level 2 10 % 150
L8-05 Phase loss input selection 0- 1
L8-38 Carrier frequency decel selection 0- 1
o2-09 Initialize mode selection 2- 0