Description and Elimination of Frequently Occurring Errors: Errors When Starting Winkfpt

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

Description and Elimination of Frequently Occurring Errors Page 1 of 8

Description and Elimination of Frequently Occurring Errors

Errors When Starting WinKFPT

Error COAPI errors 1020, 3017, WinKFPT error 1


Time of occurrence · When starting WinKFPT.

Possible cause · A logistics file is missing in the ../data/gdaten directory. The


error dialog tells you which file it is.
Debugging · Import an up-to-date assembly line data set with description
files.

· Copy the missing logistics file to the ../data/gdaten directory


by hand.

Error COAPI errors 4211, 4206, 1040, 3017, WinKFPT error 1


Time of occurrence · When starting WinKFPT.

Possible cause · The ../data/gdaten directory contains a faulty and therefore


unconvertible logistics file. The error dialog (in particular error
4206) tells you which file it is and in which line the error
occurred.
Debugging · Import an up-to-date assembly line data set with correct
description files.

· Repair the faulty logistics file in the ../data/gdaten directory by


hand.

Error WinKFPT error 300


Time of occurrence · When starting WinKFPT.

Possible causes · The interface is already being used by a different program or


possibly by a different instance of WinKFPT.

· The default interface is not correctly set up in Ediabas.


Debugging · Close the other application that is using the interface.
(Application may only be able to be seen in the task manager.)

· Use a different application (e.g. TEOF in the Ediabas\bin

file:///C:/Users/sgtma/AppData/Local/Temp/~hh9C6E.htm 2/4/2020
Description and Elimination of Frequently Occurring Errors Page 2 of 8

directory) to check whether the interface actually functions. If not:


check Ediabas and/or the interface driver.

Errors When Importing Assembly Line Data

Error ECU directory is not displayed


Time of occurrence · When selecting an assembly identification number in Comfort
mode.
Possible cause · Imported ECU directory does not contain any PABD/P-SGBD
description files.
Debugging · Import an assembly line data set with description files.

Error WinKFPT error 11


Time of occurrence · When importing a single description file.

Possible causes · The description file could not be copied.

· The file already exists in the target directory and is write-


protected.

· The file already exists in the target directory and has been
opened by an application.

· The source file has no read rights.

· No write rights in the target directory.


Debugging Depending on the cause:

· Cancel write protection.

· Close the application that has opened the file.

· Check and adapt the file rights.

Error WinKFPT error 111


Time of occurrence · When importing an assembly line data set.

Possible cause · The assembly line data set does not contain a file of type

file:///C:/Users/sgtma/AppData/Local/Temp/~hh9C6E.htm 2/4/2020
Description and Elimination of Frequently Occurring Errors Page 3 of 8

<EcuFamilyname>.dat
Debugging · Fetch the correct assembly line data set (e.g. from Darwin).

Errors When Entering Flash Data

Error COAPI errors 1065, 1000, WinKFPT error 106


Time of occurrence · When loading the suggested configuration after activating the
<Expert mode> button.

· In Comfort mode when activating the [Done] button after


selecting a ZB number and integration position.
Possible cause · The PABD from the configuration does not exist.

Debugging · Copy or import the PABD to the relevant Ediabas directory.

Error COAPI error 2000, WinKFPT error 106


Time of occurrence · When loading the suggested configuration after activating the
<Expert mode> button.

· In Comfort mode when activating the [Done] button after


selecting a ZB number and integration position.
Possible cause · The SGBD from the configuration does not exist.

Debugging · Copy or import the SGBD to the relevant Ediabas directory.

Error COAPI error 3000


Time of occurrence · In Comfort mode after entering a ZB number by hand.

Possible cause · This is no (correct) DAT file that contains the ZB number.

file:///C:/Users/sgtma/AppData/Local/Temp/~hh9C6E.htm 2/4/2020
Description and Elimination of Frequently Occurring Errors Page 4 of 8

Debugging · Import the assembly line data set for the ECU family to which
the ZB number belongs.

Error WinKFPT errors 500 to 503


Time of occurrence · When selecting the data file in Expert mode.

· When selecting the program file in Expert mode.


Possible causes · The wrong ECU has been connected. The ECU identifier in the
data/program file selected does not match up with the identifier
of the ECU connected.

· The wrong data/program file has been selected.


Debugging · Determine whether the correct ECU is connected. If necessary,
connect the correct ECU.

· Determine whether the correct data/program file has been


selected. If necessary, select the correct file.

Error COAPI error 2020


Time of occurrence · When selecting the data file in Expert mode.

· When selecting the program file in Expert mode.


Possible cause · An incorrect ECU address has been entered:

· The control unit is not connected or communication is


disrupted.
Debugging · Enter the correct ECU address.

· Connect the ECU. Check whether communication is actually


possible.

Error COAPI error 1020


Time of occurrence · When activating the [Program] button in Comfort mode.

Possible cause · An ECU family-specific logistics file (HWH or HIS) is not


present. The error dialog tells you which file it is.
Debugging · Fetch the file by importing the assembly line data

file:///C:/Users/sgtma/AppData/Local/Temp/~hh9C6E.htm 2/4/2020
Description and Elimination of Frequently Occurring Errors Page 5 of 8

· or copy the file to the data directory by hand.

Error COAPI errors 4209 or 4211, 4206, 1040, 3000


Time of occurrence · When activating the [Program] button in Comfort mode.

Possible cause · An ECU family-specific logistics file (DAT, HWH or HIS) is


faulty. The error dialog (in particular error 4206) tells you
which file it is and in which line the error occurred.
Debugging · Fetch an intact file by importing the assembly line data

· or eliminate the error in the file by hand.

Error COAPI errors 4204, 1040


Time of occurrence · When activating the [Program] button in Comfort mode.

Possible cause · The file to be flashed does not exist. The error dialog (in
particular error 4204) tells you which file it is.
Debugging · Fetch the file by importing the assembly line data

· or copy the file to the data directory by hand.

Error COAPI errors 4220 or 4209, 4221, 1040,


Time of occurrence · When selecting a program or data file in Expert mode.

· When activating the [Program] button in Comfort mode.


Possible cause · The file to be flashed is faulty. The error dialog (in particular
error 4221) tells you which file it is and in which line the error
occurred.
Debugging · Fetch an intact file by importing the assembly line data

· or eliminate the error in the file by hand.

Error WinKFPT error 100

file:///C:/Users/sgtma/AppData/Local/Temp/~hh9C6E.htm 2/4/2020
Description and Elimination of Frequently Occurring Errors Page 6 of 8

Time of occurrence · In Expert mode after selecting PABD and SGBD, when
activating the [Done] button.

Possible cause · The SGBD demands an external ECU address.

Debugging · Enter an ECU address.

Error WinKFPT error 102 or 103


Time of occurrence · In Expert mode when entering an ECU address.

Possible cause · A 2-digit, hexadecimal number has not been entered as the
ECU address.
Debugging · Enter a correct hexadecimal number.

Error WinKFPT error 107


Time of occurrence · When entering a vehicle identification number (necessary
when UIF write is active).

Possible cause · The vehicle identification number was either not a 7-digit
number or not alphanumeric.
Debugging · Enter a correct vehicle identification number.

Error WinKFPT error 108


Time of occurrence · When entering a ZB number in Comfort mode.

Possible cause · The ZB number was not a 7-digit number.

file:///C:/Users/sgtma/AppData/Local/Temp/~hh9C6E.htm 2/4/2020
Description and Elimination of Frequently Occurring Errors Page 7 of 8

Debugging · Enter a 7-digit ZB number.

Errors During Data Programming

Error CAPI error 2020 or 2021


Time of occurrence · When starting programming in both operating modes..

Possible causes · The ECU is not connected.

· The HW interface is not fully installed.

· The interface is not connected.

Debugging · Determine whether the ECU is connected.

· Re-install the interface.

· Determine whether the interface hardware is connected.

Error COAPI error 1060


Time of occurrence · When starting programming by activating the <Prog. Data>
button, following input of the PABD, P-SGBD and the program
data set in Expert mode.

Possible causes · The wrong hardware interface has been selected.

· The interface is not fully installed.

· The interface is not connected.

· The ECU is not connected.

Debugging · Determine whether the correct HW interface is displayed as


status information. If necessary, select the correct HW interface
under menu option Communication à HW interface.

· Re-install the interface.

· Determine whether the interface hardware is connected.

file:///C:/Users/sgtma/AppData/Local/Temp/~hh9C6E.htm 2/4/2020
Description and Elimination of Frequently Occurring Errors Page 8 of 8

· Determine whether the ECU is connected.

Error COAPI error 2064: Delete error in coding data (e.g. ZCS)
Time of occurrence · When starting programming by activating the <Prog. Data>
button.
Possible cause · The last programming session was not successfully completed
and terminated.
Debugging · The program must be flashed to the ECU again.

To this end, enter PABD, P-SGBD and the program data set in
Expert mode. Confirm the entries made in Expert mode by
activating the <Done> button.

Start flash programming of the control unit with the program data
set by activating the <Prog. Program> button.

file:///C:/Users/sgtma/AppData/Local/Temp/~hh9C6E.htm 2/4/2020