EXCELL PRECISION CO., LTD.

© Excell Precision Limited 2005. All rights reserved Worldwide.


The information contained herein is the property of Excell Precision Limited and is supplied
without liability for errors or omissions. No part may be reproduced or used except as
authorised by contract or other written permission. The copyright and the foregoing
restriction on reproduction and use extend to all media in which the information may be
embodied.

H2O-C V1.0 SME300000064


EXCELL PRECISION CO., LTD.

TABLE OF CONTENTS
BEFORE USING THE SCALE .................................................................................................... 2

PREPARING TO USE THE SCALE ............................................................................................ 2

CHAPTER 1 FEATURES AND SPECIFICATION........................................................................ 3

CHAPTER 2 DISPLAY ................................................................................................................ 4

CHAPTER 3 KEYBOARD FUNCTION........................................................................................ 5

3-1. EXPLANATION OF KEYBOARD................................................................................................. 5


3-2. BASIC FUNCTION OPERATION ................................................................................................ 6
3-2-1 Switching the scale on / Re-zeroing ............................................................................ 6
3-2-2 The desired units selection .......................................................................................... 6
3-2-3 The weight value of the container deduction ............................................................... 6
3-2-4 Net / gross weight value cross-display ........................................................................ 6
3-2-5 Counting mode ............................................................................................................ 7

CHAPTER 4 ADVANCED FUNCTION SETTINGS ..................................................................... 8

4-1. AUTO POWER OFF AND BACKLIGHT SETTING .......................................................................... 8


4-2. HOLD FUNCTION SETTING..................................................................................................... 9

APPENDIX 7 SEGMENTS DISPLAY CHARACTER ............................................................... 10

H2O-C V1.0 1 SME300000064


EXCELL PRECISION CO., LTD.

BEFORE USING THE SCALE


Thank you for purchasing an EXCELL H2O-C Rechargeable Waterproof Weighing
Scale. In order to use the scale properly, please read this User Manual carefully
before use. If you have a problem concerning the scale, please contact your
supplier.
1. Please keep scale in a cool place. Do not store at high temperatures.
2. Do not allow any liquids to come into or contact with the scale. If it is happened, wipe the
scale dry with a cloth.
3. Avoid objects impacting with the scale. Do not drop loads onto the scale or subject the
weigh pan to any strong shock loads.
4. The load placed on the weigh pan must not exceed the maximum weighing capacity of
the scale.
5. If the scale is not going to be used for some time, please clean it and store it in a plastic
bag in dry conditions. A desiccant sachet may be included to prevent moisture build up.
6. This product is not suitable for the trade usage

PREPARING TO USE THE SCALE


1. For accurate weight readings locate the scale on a firm level surface free from vibrations.
2. Avoid operating the scale in direct sunlight or drafts of any kind.
3. Remove any weight that might be on the weigh pan before the scale is switched on and
avoid leaving weight on the pan for long periods of time.
4. Once the scale has been switched on, it will go through a LCD display test and then
re-zero to be ready for use.
5. The scale requires 15~20 minutes warming up the machine before operation to ensure
best accuracy.
6. Please note when symbol appears on the screen, the dry batteries need to be
replaced.
7. All goods weighed should be placed in the centre of the weigh pan for accurate weighing.
The overall dimensions of the goods being weighed should not exceed the dimension of
the weigh pan.

H2O-C V1.0 2 SME300000064


EXCELL PRECISION CO., LTD.

CHAPTER 1 FEATURES AND SPECIFICATION


Features:
n Multi-function operation: Fast weighing operation; Full range tare; Net / Gross weight
display; Simple counting (pcs); Auto power-off; Weight hold feature.
n Dual-weighing units: gram (g) and ounce (oz).
n User-friendly design: Auto calibration; Auto zero tracking; Large LCD display (digit height
18.5 x 8.5 mm) with LED backlight; Gravity compensation; low battery warning indicator;
double over-load protection; Environment parameter settings .

Specifications:
Model Capacity Division Resolution Min. Cap.
H2O-C – 3 3,000g (6 lb) 1g (0.002 lb) 1/3000 20g
H2O-C – 6 6,000g (12 lb) 2g (0.004 lb) 1/3000 40g
H2O-C – 15 15,000g (30 lb) 5g (0.01 lb) 1/3000 100g
H2O-C – 30 30,000g (60 lb) 10g (0.02 lb) 1/3000 200g
Operating Temperature 0°C ~ 40°C (32°F ~ 104°F)
Power Source AC mains adaptor DC 10 V or Rechargeable battery 6V / 5 Ah
Weight pan Size 190 x 225 mm

H2O-C V1.0 3 SME300000064


EXCELL PRECISION CO., LTD.

CHAPTER 2 DISPLAY

1 5
2 6

TARE 1 : “Tare” indicator.


ZERO 2 : “Zero” indicator.
► 3 : Gram (g), the 1st unit indication.
► 4 : Ounce (oz), the 2nd unit indication.
► 5 : None.
► 6 : Piece unit (pcs), the 4th unit indication.

: “Low Battery” indication.

H2O-C V1.0 4 SME300000064


EXCELL PRECISION CO., LTD.

CHAPTER 3 KEYBOARD FUNCTION


3-1. Explanation of Keyboard
1. OFF : The key to switch the scale off.

ON
2. ZERO : ON/ZERO key. When the scale is off, press the key to switch it on. When

the scale is switched on, with the weigh pan empty, press this key to zero (balance) the

scale, if the display is not showing zero. To exit the Tare mode, press the key as well.

3. TARE : TARE key. Press the key to deduct the weight of the container.

v The tare key is not functional when the weight value shown on the display is negative or

over the full scale capacity.

4. UNITS : Units key. Press the key to select the desired weight unit or the count unit

(pcs).

NET
5. GROSS
: Gross weight / Net weight key. (The key is ONLY functional in the Tare mode)

The gross weight = Tare weight + Net weight

v Only the Gross weight / Net weight key is functional, when the scale in the Tare mode.

H2O-C V1.0 5 SME300000064


EXCELL PRECISION CO., LTD.

3-2. Basic Function Operation

3-2-1 Switching the scale on / Re-zeroing


ON
1. When the scale is off, press ZERO
key to turn the scale on.
ON
2. When the scale is on and without any object placed on the weigh pan, press ZERO key
to obtain a zero reading. The ”ZERO” indication shows in the left hand side of the display.

3-2-2 The desired units selection

Press the UNITS key to select gram (g), ounce (oz) or pcs, ” ►” the indication will show in
the right hand side of the display. After power off, the scale will memorise the active units. When
the scale is powered on again, it displays the previous active units.

3-2-3 The weight value of the container deduction


TARE
1. Place the container on the weigh pan. After stable, press key to deduct the weight
value of the container.
2. Place the object in the container, the scale will show the net weight value of the object.
3. Remove the container and weighing object, and the display shows the negative weight

value of the container. Press TARE key to clear the weight value of the container, and
the ”TARE” indication goes off.

v Tare continuously (Press TARE key, when weight is added or deducted on the weigh
pan).
v Tare value = The full capacity (The scale can be tarred continuously to the full capacity).

3-2-4 Net / gross weight value cross-display


NET
1. In the tare mode, the display shows the ”TARE” indication on the left hand side. Press GROSS

key to show the gross weight value, and ” TARE” the indication goes off.
NET
2. Press GROSS key again, the display shows the net weight value and the ”TARE”
indication shows again.
NET
3. The GROSS
key is ONLY functional in the tare mode.

H2O-C V1.0 6 SME300000064


EXCELL PRECISION CO., LTD.

3-2-5 Counting mode


UNITS
1. Press key to select the piece unit (pcs), and enter the counting mode.
NET
2. Press GROSS key to select the counting sample size 10, 20, 50, 100, or 200, and the
display shows , , , , or

3. Place the samples on the weigh pan, then press UNITS. The display shows “ ”.
After the weight is stable, the scale shows the quantity of the samples. After the sampling
process is completed, put the goods on the weigh pan and the screen shows the quantity of
the goods.

v The scale memorizes the selected sample quantity, after turning off the scale. The scale will show
the same selected sample quantity, when entering the counting mode next time.

v If the quantity of the items weighed larger than 65536 (pcs), the display shows the error message
“ ”.

H2O-C V1.0 7 SME300000064


EXCELL PRECISION CO., LTD.

CHAPTER 4 ADVANCED FUNCTION SETTINGS


4-1. Auto Power off and Backlight Setting
ON NET
Switch on the scale, then press ZERO and GROSS keys together to enter the
advance function settings mode. The display shows 。

The display shows the last setting

Auto power off timer setting


Press the ON/ZERO key to enter a parameter.
0 ⇒ No auto power-off
Press the ON/ZERO key 1 ⇒ When the scale is idle for 1 minute, the
to enter a parameter scale automatically switches off
2 ⇒ When the scale is idle for 2 minutes, the
scale automatically switches off

Press the TARE key


19 ⇒ When the scale is idle for 19 minutes, the
scale automatically switches off

Press the ON/ZERO key


The display shows the last backlight setting
to enter a parameter

Auto backlight setting


Press the ON/ZERO key to enter a parameter.

on ⇒ Auto Backlight on
ON/ZERO ⇒ Increment digit (from 0 to 9)
off ⇒ Auto Back light off
TARE ⇒ Confirm / enter key
NET/GROSS ⇒ Move the cursor to the right

Automatic power-off function


When the weight on weigh pan is less than 10d or remains steady for the set time, the scale
will automatically switch off.
v Automatic power-off is not functional, when using an ac adaptor as the power source.
Therefore, auto power-off is ONLY active, when using battery as the power source.

Auto Backlight Function


When the weight is over 10d, the backlight is on. After the weight is stable for 10 seconds or
when the scale returns to zero, the backlight switches off.

H2O-C V1.0 8 SME300000064


EXCELL PRECISION CO., LTD.
4-2. Hold Function Setting

Press the TARE key Hold function setting


LCD displays the last parameter setting

Use the ON/ZERO key to Hold function setting


enter a parameter Use the ON/ZERO key to input a parameter
Default setting = 0
0 ⇒ Hold function disabled
Press the TARE key to 1 ⇒ “Peak hold” mode
complete the advance 2 ⇒ “Stable hold 1” mode
function setting 3 ⇒ “Stable hold 2” mode

Back to weighing mode

ON/ZERO ⇒ Increment digit (from 0 to 9)


TARE ⇒ Confirm / enter key
NET/GROSS ⇒ Move the cursor to the right

= Hold function disabled.

= “Peak hold” mode


The hold function is active, when the weight on the pan is larger than 10d).
The scale shows the maximum weight value detected from the continuously changing
weight values. Press any key to exit the hold function.

= “Stable hold 1” mode


The hold function is active, when the weight on the pan is larger than 10d).
After the scale is stable, the display shows the current weight value. Press any key to exit
the hold function.

= “Stable hold 2” mode


The hold function is active, when the weight on the pan is larger than 10d).
After the scale is stable, the display shows the current weight value. Re-zero the scale to
exit the hold function.

H2O-C V1.0 9 SME300000064


EXCELL PRECISION CO., LTD.

APPENDIX 7 SEGMENT DISPLAY CHARACTERS

Digit 7 segments letter Alphabet 7 segments letter Alphabet 7 segments letter

0 A N

1 B O

2 C P

3 D Q

4 E R

5 F S

6 G T

7 H U

8 I V

9 J W

K X

L Y

M Z

H2O-C V1.0 10 SME300000064