Kinetrol Actuators and Add-On Control Units: Abbreviations
Kinetrol Actuators and Add-On Control Units: Abbreviations
Kinetrol Actuators and Add-On Control Units: Abbreviations
Ordering Codes
ACTUATOR ACTUATOR or SWITCH OPTIONS
MODEL ACTUATOR/SOLENOID SPRING RETURNS (see pages 31 to 34)
SIZE/THREAD VALVE ASSEMBLY
Actuator
0
EXAMPLES
D. 144-130-4900 144 actuator (Metric threads) + spring return fail-safe ccw (2 x 124 springs)
30
Offers a wide range of signalling options in a fully enclosed,
corrosion resistant metal case. Available for direct mounting
onto Kinetrol rotary actuators or discrete mounting via
an industry standard VDI/VDE interface onto any make of
VLS/ULS Limit
Specification Units sealed to IP67/NEMA 6 (ATEX units IP66/NEMA 4X, IP67 option available)
Two or four cable entries as standard to allow back wiring of solenoid valves
Cable entry options
2 or 4 entries
Multiple switch options available for general and hazardous areas
M20 x 1.5 Conduit thread
or AS Interface bus circuit option inside box reads up to 4 switch inputs, drives up to
1/ NPS Conduit thread
2 2 solenoids powered by bus only (see pages 35 & 36)
4 Way plug DIN 43650A
DeviceNet option inside box with various network speeds allows 2 on / off inputs and
(fits either conduit thread)
drives up to 2 solenoids (see page 37)
4 Way M12 Connector
(M20 Conduit thread only) Optional Clear Cone monitor available
Dimensions Integral LED indicator lamps and angle retransmit circuit options are available
See page 61
Compact SPST version of type 004 available for model 02 actuator
VLS/ULS Limit
for hazardous areas (ATEX CAT 1), microswitches for SPDT (ATEX CAT 1).
Switch Box
normally closed. Ambient temperature range -20°C to +80°C
Ambient temperature range -20°C to +80°C
Switch Type 00E
Switch Type 002 2 x 2 wire proximity sensors 20-140 volts AC /
2 pneumatic switches with 4mm (5.32”) push in 10-140 volts DC.
fittings (ATEX CAT 2), normally closed. Ambient temperature range -25°C to +80°C
Ambient temperature range -15°C to +60°C
Switch Type 00M
Switch Type 003 4 x 3 wire inductive proximity sensors
Certificated unit to EEx ed II T6 for hazardous areas 10-30 volts DC, normally open.
to Zone 1 (ATEX CAT 2) 2 x 3 wire switches for Ambient temperature range -25°C to +70°C
SPDT.
Ambient temperature range -20°C to +70°C Switch Type 00N
2 x 3 wire inductive proximity sensors
Switch Type 004 10-30 volts DC, normally open.
2 x 3 wire microswitches for SPDT. Ambient temperature range -25°C to +80°C
Ambient temperature range -40°C to +80°C
Electronics Option B - E
Switch Type 005 AS interface options are available with both
2 x 2 wire proximity sensors 20-250 volts AC, the two and four entry Kinetrol Universal Limit
normally open. Switch Box. Options B to E allow for
Ambient temperature range -25°C to +70°C different extended addressing options. For
more information on the Kinetrol AS
Switch Type 006 interface card see page 35 & 36.
2 x 2 wire proximity sensors 5-60 volts DC, normally
open, with Led switch status indicators. Electronics Option P
Ambient temperature range -20°C to +80°C Two or four way Universal Limit Switch Box
fitted with potentiometer (20K ohms
Switch Type 007 conductive plastic type).
4 x 3 wire microswitches for DPDT.
Ambient temperature range -40°C to +80°C Electronics Option R
Two or four entry Universal Limit Switch Box
Switch Type 008 fitted with angle retransmit, loop powered two
2 x 2 wire inductive slotted proximity sensors, wire circuit passes 4-20mA current,
normally closed. proportional to 0-90° position of actuator.
Ambient temperature range -20°C to +80°C
Electronics Option U (standard)
For ATEX ratings please refer to TD139 Two or four entry Universal Limit Switch Box
without AS interface card, angle retransmit
SWITCH TYPE or potentiometer.
1=2x V3 i-SAFE PROXIMITY SENSORS ATEX
2=2x PNEUMATIC SWITCHES ATEX ELECTRONICS OPTION 0=DIRECT MOUNT UNIT
3=2x SWITCHES EExe II T6 CERTIFIED ATEX B=WITH ASi BUS † (See KF-496) 1=DISCRETE UNIT WITH KINETROL SQUARE
4=2x V3 SPDT SWITCHES † C=ASi EXTENDED ADDRESSING, 2=DISCRETE UNIT WITH NAMUR INTERFACE
5=2x 20-250Vac PROX. SENSORS † OUTPUTS DISABLED † 3=DISCRETE UNIT WITH KINETROL SQ.+HI TEMP SEALS †
6=2x 5-60Vdc PROX.SENSORS † D=ASi EXTENDED ADDRESSING, 4=DISCRETE UNIT WITH NAMUR INTERFACE+HI TEMP SEALS †
7=4x V3 DPDT SWITCHES † OUTPUTS ENABLED † 5=DIRECT MOUNT BOX+HI TEMP SEALS †
8=2x SLOTTED PROX SENSORS † E=ASi EXTENDED ADDRESSING,
9=2x V3 SPDT i-SAFE (GOLD PLATED) ATEX OUTPUTS ENABLED, SEPARATE
A=4x CODE 1 SENSORS 7.530Vdc † POWER SUPPLY † 0= 2X3 CONNECTION TERMINAL BLOCKS
B=4x CODE 5 SENSORS † U=WITHOUT ELECTRONICS 4= 3X3 CONNECTION TERMINAL BLOCKS
C=4x CODE 6 SENSORS † R=WITH ANGLE RETRANSMIT † 5= 4X3 CONNECTION TERMINAL BLOCKS †
D=4x CODE 9 SWITCHES † P=WITH POTENTIOMETER † 6= MULTI-TERMINAL PCB (5x3 + 1x2) †
E=2x V3 20-140Vac / 10-140Vdc INDUCTIVE SENSORS †
F=4x CODE E SENSORS †
M=4x 10-30Vdc PNP 3 WIRE PROX. SENSORS † M=CLEAR CONE MONITOR - STANDARD †
N=2x 10-30Vdc PNP 3 WIRE PROX. SENSORS † B R=CLEAR CONE MONITOR - EXTRA CHEMICAL RESISTANCE †
C A=CLEAR CONE MONITOR - ATEX (SWITCH OPTION 1 & 9 ONLY)
0=NO ACTUATOR D
0=NO LED FITTED
1=ACTUATOR E 1=2 LED'S RED + GREEN 240 / 110 V ac †
ACTUATOR U 2=2 LED'S RED + GREEN 12 / 24 V dc †
MODEL 3=2 LED'S RED + GREEN WITH ASi BUS †
R
03 - 60
RH P 0=PNEUMATIC SWITCH CONNECTION
For more information
1=2 ENTRIES - 2 TRANSIT PLUGS
4=M20 (ISO)
7=1/2" NPS
2=2 ENTRIES - 1 TRANSIT, 1 BLANKED (R.H.) see KF-487
3=2 ENTRIES - DIN PLUGS †
APPROVAL TYPE 4=2 ENTRIES - DIN PLUG, 1 BLANKED (R.H.) †
SPRING 5=4 ENTRIES - 4 TRANSIT PLUGS †
V= STANDARD
LH OPTIONS 6=4 ENTRIES - 3 TRANSIT, 1 BLANKED (R.H.)
0=ATEX
0=NO SPRING 7=4 ENTRIES - 4 DIN PLUGS †
(001, 003 & 009)
2=CW SPRING 8=4 ENTRIES - 3 DIN PLUGS, 1 BLANKED (L.H.) †
3=CCW SPRING 9=4 ENTRIES - 2 DIN PLUGS, 1 BLANKED (L.H.), 1 TRANSIT †
0= NO ANGLE RETRANSMIT
† NOT AVAILABLE ON ATEX VERSIONS 1= ANGLE RETRANSMIT CW † PLUG OPTIONS FOR AS INTERFACE †
2= ANGLE RETRANSMIT CCW † A=M12 PLUG FOR AS INTERFACE & TRANSIT (RH)
B=M12 PLUG, M12 SOCKET WITH ASI CABLE CLAMP & TRANSIT (RH)
C=M12 PLUG FOR AS INTERFACE & BLANK (RH)
EXAMPLES: D=M12 PLUG, M12 SOCKET WITH ASI CABLE CLAMP & BLANK (RH)
054-001U001000 = 05 ULS BOX WITH 2 X V3 ISAFE PROXIMITY SENSORS, 2 TRANSIT PLUGS, 2 X 3 WAY TERMINALS, ATEX APPROVED Unless otherwise specified M12 plug will always be connected on the left side port
074-004UV01000 = 07 VLS BOX WITH 2 X V3 SPDT SWITCHES, 2 TRANSIT PLUGS, 2 X 3 WAY TERMINALS
074-004RV12000 = 07 VLS BOX WITH 2 X V3 SPDT SWITCHES, ANGLE RETRANSMIT CLOCKWISE,1 X TRANSIT & 1 BLANKING PLUG, 2 X 3 WAY TERMINALS
094-124BV02000 = 09 SPRING RETURN CLOCKWISE ACTUATOR & VLS BOX WITH 2 X V3 SPDT SWITCHES,STANDARD ASi, 2 TRANSIT PLUGS, 2 X 3 WAY TERMINALS
094-109U001000 = 09 DOUBLE ACTING ACTUATOR, ULS BOX WITH 2 X V3 ISAFE MECH. SWITCHES GOLD PLATED, 2 TRANSIT PLUGS, 2 X 3 WAY TERMINALS, ATEX APPROVED
Further switch options are available upon request -contact Kinetrol for details
32
Explosion Proof Limit
Wide range of worldwide explosion proof approvals including IECEX, ATEX & FM
(for USA & Canada) - all in one device
Discrete Kinetrol 05 square drive insert for use with Kinetrol actuator models 16 - 60
Discrete NAMUR drive for use with VDI/VDE 3845 drive actuators
Integral AS interface bus circuit option reads up to 4 switch inputs and drives up to
2 bus powered solenoids
33
Explosion Proof Limit
Switching Operation Conditions Specification
Switch Voltage Temperature
Switch Box
Current NORTH AMERICAN APPROVAL
Code AC DC Range
Type of US: Class I, Division 1, Gas groups
1/A — 8 6mA -20°C to +80°C protection, B,C,D. Class II, Division 1, Dust groups
Explosion E,F,G. T5 NEMA 4X.
4/7 250 48 2.4A AC/1.8A DC -40°C to +80°C
Proof For Gas group A use order code “P”.
5/B 250 300 100mA -25°C to +70°C CANADA: Class I, Division 1, Gas
groups B,C,D. Class II, Division 1,
6/C — 60 100mA -20°C to +80°C Dust groups E,F,G. T5 TYPE 4X.
9/D — 30 100mA -40°C to +80°C
EUROPE/GLOBAL - ATEX / IECEx APPROVAL
E/F 140 140 200mA -25°C to +80°C Protection Group II C/A21, Category 2, Gas &
M/N — 30 100mA -25°C to +70°C concept, Dust, T5, IP66
Flame Proof ‘d’
Labels
Casing precision diecast LM24 alloy, anodised
IECEx & ATEX - Approval type E & epoxy stove enamel.
Weight 1.5 kg
Ordering Codes
B = 2 ENTRY 0 = CLOSE-MOUNT (03-14 MODEL-SPECIFIC)
D = 4 ENTRY 1 = DISCRETE KINETROL 05 SQUARE DRIVE (16-30 MODEL-SPECIFIC)
APPROVAL TYPE 2 = DISCRETE NAMUR
E = IEC / ATEX IIC, IIB, IIA 3 = NO MOUNTING PARTS (NON MODEL-SPECIFIC)
F = FM / FMC GRPS B,C,D
P = FM GRP A NOTE: ACTUATORS 16 - 60 REQUIRE DISCRETE MOUNTING
MOUNTING PARTS AVAILABLE:
SP1601 - 05 SQUARE DRIVE
SWITCH OPTIONS SP1602 - 07/05 SQUARE REDUCER
(SUPPLIED WITH 2 STRIKERS AS STANDARD) SP1603 - NAMUR DRIVE
1 = 2 x V3 7.5-30Vdc, NC, 2 WIRE INDUCTIVE SENSORS SP1604 - 07/03 SQUARE REDUCER
4 = 2 x V3 SPDT, 0-250Vac, MECHANICAL MICROSWITCHES SP/ASP1607 - CLOSE MOUNTING KIT
5 = 2 x V3 20-250Vac / 10-300Vdc NO, 2 WIRE, INDUCTIVE SENSORS SP/ASP1608 - 12/14/15 ACCESSORY MOUNTING ADAPTOR (UNDRILLED)
6 = 2 x V3 5-60Vdc, NO, 2 WIRE, INDUCTIVE SENSORS SP/ASP389 - MODEL 16 MOUNT KIT
7 = 4 x CODE 4 MICROSWITCHES SP/ASP329 - MODEL 18 MOUNT KIT
9 = 2 x V3 SPDT, GOLD PLATED CONTACTS SP/ASP400 - MODEL 20 - 60 MOUNT KIT
MECHANICAL MICROSWITCHES
A = 4 x CODE 1 SENSORS
B = 4 x CODE 5 SENSORS TERMINALS NEEDED FOR OPTIONS
C = 4 x CODE 6 SENSORS NO BACKWIRING
D = 4 x CODE 9 MICROSWITCHES ASI + 2 OR 4 SWITCHES = 2x3 (0)
E = 2 x V3 20-140Vac / 10-140Vdc, NO, 2 WIRE, INDUCTIVE SENSORS A/R + 2 SWITCHES = 2x3 (0)
F = 4 x CODE E SENSORS A/R + 4 SWITCHES = PCB (6)
M = 4 x 10-30Vdc, PNP, 3 WIRE, PROXIMITY SENSORS 0 = 2 x 3 TERMINALS
POT + 2 OR 4 SWITCHES = PCB (6)
N = 2 x 10-30Vdc, PNP, 3 WIRE, PROXIMITY SENSORS 4 = 3 x 3 TERMINALS
5 = 4 x 3 TERMINALS 2 SWITCHES = 2x3 (0)
0 = NO SR 6 = MULTI-TERMINAL PCB (2x6 + 1x3 + 1x2) 4 SWITCHES = 4x3 (5)
2 = SR CW WITH BACKWIRING
3 = SR CCW
0 = WITHOUT ACT A/R + 2 SWITCHES = PCB (6) For more information
1 = WITH ACT A/R + 4 SWITCHES = PCB (6)
0 = STANDARD INDICATOR POT + 2 SWITCHES = PCB (6)
see KF-619
— = MALE
F = FEMALE A = ANTI-STATIC MONITOR POT + 4 SWITCHES = PCB (6) SEE NOTE
S = SERRATED 2 SWITCHES = 3x3 (4)
– X 0 4 SWITCHES = PCB (6)
An AS Interface bus can be used as the final Up to 31 24V 2.5W solenoid valves can be
field link in a more complex hierarchy of devices connected to bus with no separate power
making up a large plant-wide control system. supply
Actuators and sensors must often be installed in
unprotected environments where conditions can M12 connector plug option available for
be demanding; the AS Interface bus can be instant bus connection
used as the link between these field devices and
the "indoor" equipment making up the upper part Cable clamping connector block for yellow
of the control system. ribbon-type AS interface cable available with
M12 socket to fit onto plug option
The AS Interface bus is designed for on/off
control and monitoring. It is a good choice when Output short circuit protection built in
a simple, economical, reliable and robust
solution is required for controlling and monitoring Operating temperature range
a series of actuators and sensors in a process -20°C to +80°C
control or machine application. (-40°C option available - contact Kinetrol)
35