Member Schedule Mark Member Size Max Span: Control Joint

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

01

02 S04
S04

DS
L1
04
DS S04
MEMBER SCHEDULE
MARK MEMBER SIZE MAX SPAN
GT4
L2 L3 L4 1 L1 90 x 45 MGP10 + 90 X 90 X6 EA 950 mm
DS

1
DS
SL17

L2 140 x 45 MGP10 + 90 X 90 X 6 EA 1550 mm


L3 240 x 45 MGP10 + 90 X 90 X 10 EA 2150 mm
GT1
L4 2/ 240 x 45 MGP10 + 90 X 90 X6 EA 1550 mm
03
L5 2/ 290 x 45 MGP10 + 150 X 10 X12 EA 3750 mm
S04

L5
CONTROL JOINT
L6 190 x 45 MGP10 + 90 X 90 X 6 EA 1550 mm

PB1 L7 140 x 45 MGP10 + 90 X 90 X 6 EA 1550 mm


L18 L8, L13, L14 90 x 45 MGP10 + 90 X 90 X6 EA 700 mm
L16

L9 190 x 45 MGP10 + 90 X 90 X 6 EA 1650 mm


L10, L11 190 X 45 MGP10 + 90 X 90 X 6 EA 1550 mm
L12 2/ 290 x 45 MGP10 + 90 x 90 x 6 EA 1550 mm
L15 190 x 45 MGP10 + 100 X 100 X 12 EA 2600 mm
L16 140 X 45 MGP10 + 90 X 90 X 6 EA 1300 mm
L15

GT2 SL17 230 x 75 PFC, 175 mm x 10 mm Pl. Horz 4900 mm

L6
PB2

GT3 L18 190 X 45 MGP10 950 mm


1

L11 L10
DS

DS

L14 L13 L12 L9 L8 L7


PB1 190 x 45 MGP10 2400 mm

PB2 300 x 75 hySPAN 6250 mm

DS 2/ 90 X 45 MGP10 -

DS1 2/ 90 x 45 F17 KDHW -

NOTE:
1) IF NOT SPECIFIED ON THE PLAN, ALL LINTELS TO BE SUPPORTED BY 2/ 90 X 45 MGP10 DOUBLE
STUDS
2) ALL EQUAL ANGLE LINTELS TO HAVE MINIMUM 150 MM END BEARING LENGTH
NOTE:
IF ROOF TRUSS DIRECTION OR GIRDER TRUSS LOCATIONS ARE TO DIFFER THAN AS SHOWN HERE, THIS OFFICE IS TO BE CONTACTED 3) LAMINATION OF TIMBER MEMBERS TO BE DONE BASED ON RECOMMENDATIONS PROVIDED IN IS
FOR FURTHER ADVICE PRIOR TO CONSTRUCTION 1684.

Project: Status: NOTES: Revision: Date: Details: Sheet Size: Date: Drafted by:
The Contractor Shall Verify All Dimensions At - - - A3 20/07/2020 B.G.
Single Storey Dwelling ISSUED FOR CONSTRUCTION
The Site Before Commencing Any Work
Shown Hereon. Designed by: Checked/Approved Revision No:

Address: ................................................................... ©These drawings are sole property of Engineers B.G. by: J.S. 00
NORTH
Sheet Title: Institute Australia and no part of these drawings shall Job No. Drawing No. Scale:
ROOF AND FRAMING PLAN be used without written formal permission from
Engineers Institute Australia 200218 S03 1:100