0% found this document useful (0 votes)
253 views1 page

Legend Waffle Slab Plan

The document provides specifications for waffle slab parameters including dimensions for box height, slab thickness, rib widths, stem width, overall depth, and rib spacing. It also includes reinforcement requirements, with extra bottom reinforcement needed for edge beams wider than 300mm. Reinforcement includes slab mesh, rebar in internal and external ribs, and minimum edge beam width is 300mm unless otherwise specified on the footing plan.

Uploaded by

rao_vinay8296
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
253 views1 page

Legend Waffle Slab Plan

The document provides specifications for waffle slab parameters including dimensions for box height, slab thickness, rib widths, stem width, overall depth, and rib spacing. It also includes reinforcement requirements, with extra bottom reinforcement needed for edge beams wider than 300mm. Reinforcement includes slab mesh, rebar in internal and external ribs, and minimum edge beam width is 300mm unless otherwise specified on the footing plan.

Uploaded by

rao_vinay8296
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

GENERAL WAFFLE PARAMETERS

BOX HEIGHT 300 mm


SLAB THICKNESS 100mm
INTERNAL RIB WIDTH 110 mm
EXTERNAL RIB WIDTH 300 mm
STEM WIDTH 150 mm
OVERALL DEPTH 385 mm
RIB SPACING 1200 max

IF EDGE BEAMS ARE WIDER THAN 300 MM, BOTTOM


REINFORCEMENT TO BE PROVIDED BASED ON THE
TABLE BELOW.

GENERAL WAFFLE PARAMETERS


EXTRA WIDTH BOTTOM REINFORCEMENT
110 MM - 150 MM 4-L12TM
151 MM - 220 MM 5-L12TM

REINFORCEMENT
SLAB MESH SL82
INTERNAL RIB 1 N12 BAR BOTTOM AND 1 N12 BAR TOP
EXTERNAL RIB 3-L12TM BOTTOM OR 3 N12 AND 1N12 BAR TOP

WAFFLE SLAB PLAN


LEGEND NOTE:
ALL FOOTINGS TO BE FOUNDED AT LEAST 200MM INTO THE UNDERLYING NATURAL SILTY CLAY.
ALL GROUND FLOOR SLAB TO BE f'c =25 MPA
INDICATES 3L12TM (OR 3-N12 BARS) 2000MM LONG TIED TO UNDERSIDE OF SLAB
MESH LAPS AT INTERNAL CORNERS ALL THE EDGE BEAMS & INTERNAL BEAMS TO BE MIN 300MM
WIDE UNLESS SPECIFIED ON FOOTING PLAN
INDICATES STARTING POINT FOR LAYING OF VOID FORMERS

SHADED AREA INDICATES AREA WHERE VOID FORMERS ARE SET


DOWN. REFER TO DETAILS SHEET

HATCHED AREA INDICATES INTERNAL LOAD BEARING WALLS

HATCHED AREA INDICATES SHOWER RECESS

Project: Status: NOTES: Revision: Date: Details: Sheet Size: Date: Drafted by:
The Contractor Shall Verify All Dimensions At - - - A3 20/07/2020 B.G.
Single Storey Dwelling ISSUED FOR CONSTRUCTION
The Site Before Commencing Any Work
Shown Hereon. Designed by: Checked/Approved Revision No:
B.G. by: J.S. 00
Address: ................................................................... ©These drawings are sole property of Engineers
NORTH
Sheet Title: Institute Australia and no part of these drawings shall Job No. Drawing No. Scale:
be used without written formal permission from
WAFFLE FOUNDATION PLAN 200218 1:100
Engineers Institute Australia S01A

You might also like