GEOT2000 Laboratory 1: Sieve Size (MM) Weight of Empty Sieve (G) Weight of Sieve With Retained Mass (G)
GEOT2000 Laboratory 1: Sieve Size (MM) Weight of Empty Sieve (G) Weight of Sieve With Retained Mass (G)
Hydrometer test
After the sieving, 50g of sample less than 0.075mm retained on the pan were taken for the
hydrometer test.
Temperature recorded during the test: 27C. Specific gravity, Gs, of fine-grained particles = 2.65
The correction factor of hydrometer test:
a) Correction factor due to dispersing agent C = 2.5
b) Meniscus correction Cm = 0.5
0.5 36
1 35
2 34
4 32
8 31
15 29
Your task is to
1. Complete the calculation in the worksheet
2. Plot the Particle Size Distribution Curve
GEOT2000 Laboratory 1
Total sample mass, Mt: _________________
Sieving Analysis
Hydrometer Analysis
Temp Particle % Passing
Elapsed time Temp Corr. Hydro. Readings Corrected % Passing
Rh = R'h + Cm Rc = Rh + Ct + Ca Diameter
[min] [oC] Ct R'h P
D [mm] P'
0.5
15
GEOT2000 Laboratory 1
Particle Size Distribution Analysis
120
Lab
Name: ID: Group:
100
80
% Passing
60
40
20
0
0.001 0.01 0.1 1 10 100
Particle size (mm)
0.002 0.006 0.02 0.075 0.2 0.6 2.36 6.0 20.0 63.0
silt sand gravel
clay cobbles
fine medium coarse fine medium coarse fine medium coarse