AR-727iV3: Part NO. AR-727i V3 AR-727CM V3

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

SOYAL

®
AR-727iV3 / AR-727CM V3 V110107
ACCESS CONTROL SYSTEM

Contents
AR-727iV3
1 Product AR-727iV3 Supports varies Ethernet protocol (TCP server/TCP), which is a Serial-to-Ethernet device to connect to
networking.
Small volume with compact design, 45mm*28mm size less than a semi credit card, easily connect to Serial device
to get on networking with 10/100M.
AR-727CM V3
1 Product 2 User Guide 3 Accessories
32 bits/50MHz ARM CPU upgrades serial device to networking device.
Compatible with 5V and 3V system.
Dual UART port supported and 4K/4K Rx/Tx buffer.
Easy to use with compact volume. Need for external components.
10/100 Mbps auto-negotiation Ethernet interface.
The Virtual COM software builds 1-255 virtual series communication ports
onto your computer.

Specification
Part NO. AR-727i V3 AR-727CM V3
Type 36-pin 2mm compact package Ethernet to Serial Port Device
Input Voltage 5 VDC (±5%) 9-24 VDC (±5%)
Power Consumption <0.5W <2W
Dimensions 45(L)x28(W)x14(H) 106.5(L)x66(W)x27.7(H)
Port 1 TTL 3.3VDC (Rx, Tx, RTS, CTS) RS-232 (Rx, Tx, RTS, CTS) RS-485 (A+, B-)
Port 2 TTL 3.3VDC (Rx, Tx, RTS, CTS) RS-485 (A+, B-)
RS-485 Transmission Direction Control RTS pin -
Interface 10/100M Base T Ethernet UART(TTL) 10/100M Base T Ethernet RS-232/RS-485
Active Distance - 2M/RS-232 300M/RS-485
Surge protection - 16KV
N.W.(g) 15 86±5
Thunder Protection 1.5KV
Data Bits 8, 9
Stop Bits 1, 2
Parity Check None, Even, Odd
Baudrate 4800-115200 bps
Network Protocols ARP, IP, TCP Client, UDP, ICMP, HTTP, DHCP, NetBIOS, SNMP V1, V2, V3,
Software Configuration Interface Web Console
Operating Temperature -20℃~+60℃
Operating Humidity 5 to 95% RH

727i V3 Diagram
VCC
a.AR-727i V3 Connects to RS-485 b.AR-727i V3 Connects to RS-232
VCC

R10 C3 U1
1K 104P CN2
1 16 C4 A+ 1
C1 C1+ VCC 104P
2 15 DB9-6 6
104P V+ GND PC_RX
3 14 PC_CTS 2
C1- T1OUT PC_RTS
4 13 PC_RTS 7
C2+ R1IN PC_TX
5 12 U0CTS Pin 20 3
C2- R1OUT PC_CTS
C2 6 11 U0RTS Pin 21 8
104P V- T1IN
DB9-4
7 10 U0TX Pin 19 4
Q1 PC_RX T2OUT T2IN
8 9 U0RX Pin 18 B- 9
R11 2N2222A PC_TX R2IN R2OUT
5
U0RTS
Pin 21
10K DS232 GND DB9
C5
104P

GND

GND
GND GND
727i J1

R15 VCC c.AR-727i V3 Connects to RJ-45 1


RV1 10K U3 2
CN1
SA85CA 8 2 3
F1 VCC RE
B- FUSE1 7 U0RX Pin 18 8 4
1
B R
G_GND

A+ 6 3 7 R18 75 5
A DE RX-
F2 5 4 U0TX Pin 19 6 6
FUSE2 GND D
RV2 R16 5 7
SA85CA 10K SN75176BP R17 75
4 8
RX+ C12
GND 3 9
TX- 103P/1206/1KV
2 10
TX+
1 11
GND VCC BASE
12
RJ45
Shading 2.0mm

Copyright by SOYAL Technology Co., Ltd.. All rights reserved.


Serial to Ethernet Device
10/ 100 Base-T V110107

AR-727i V3 PIN Assignments


J1 J2 J3 J1
Pin No. Signal Description
1 24 36 1 5V Power input.
78.74mil(2mm)
1123mil
2 NET RX(-) Ethernet Network Receive Data(-).
28.52mm 3 NET RX(+) Ethernet Network Receive Data(+).
4 5V Power input
5 BUSY LED Low active for external LED Driver to indicate busy status.
6 LINK LED Low active for external LED Driver to indicate cable connected status.
866.14mil
(22mm) 7 ACT LED Low active for external LED Driver to indicate TCP/UDP connect status.
8 RX/TX LED Low active for external LED Driver to indicate Ethernet RX/TX status.
9 GND Power input.
12 13 25
10 NET TX(-) Ethernet Network Tranceive Data(-).
1598.43mil(40.6mm)
78.74mil(2mm) 11 NET TX(+) Ethernet Network Tranceive Data(+).
1835.363mil(46.6mm)
12 BASE Connect to shading through 103P/2KV capacitor.
J2 J3
Pin No. Signal Description Pin No. Signal Description
24 GND Power input. 36 V33 3.3V voltage output.(max 20mA)
23 Reserved 35 Reserved
22 Reserved 34 U1 RTS UART channel 1 Request to Send.
21 U0 RTS UART channel 0 Request to Send. 33 U1 CTS UART channel 1 Clear to Send.
20 U0 CTS UART channel 0 Clear to Send. 32 U1 RX UART channel 1 Receive Data.
19 U0 TX UART channel 0 Tranceive Data. 31 U1 TX UART channel 1Tranceive Data.
18 U0 RX UART channel 0 Receive Data. 30 Reserved
17 Factory Reset Connect to ground more then 3 seconds will reset the module 29 Reserved
to Factory Default Value. 28 Reserved
16 DHCP AR-727i support Auto Configuration of the IP and gateway 27 Reserved
addresses and subnet mask function, but must make sure the 26 Reserved
DHCP Server is active. 25 Reserved
15 50Hz 50Hz square ware output for external watchdog strobe use.
14 Reset Low active. System reset input.
13 GND Power input.

AR-727CM V3 (2 UART Ports): Connection and Configuration

A. IP setting D. DIP Switch Settings


DIP Switch 1 2 3 4
Normal Run Mode RS-232 ON OFF
and Networking Setup Two RS-485 Wires OFF ON
DHCP Enable (Auto IP Address Configuration) ON
DHCP Disable (Auto IP Address Configuration) OFF

CH2 CH1
POWER
RS-485 RS-485 RS-232
B. Normal use LB- LA+ LB- LA+ RTS Tx Rx CTS GND V12
1 2 3 4 5 6 7 8 9 10
20 19 18 17 16 15 14 13 12 11
COM N.C. N.O. DO1 DO2 DO3 DI3 DI2 DI1 DI0

C. Remoe use (Server mode and client mode)

RS-485 RS-485 RS-232


Power

※ CH1 only can select either RS-485 or RS-232.

Copyright by SOYAL Technology Co., Ltd.. All rights reserved.


SOYAL
®
AR-727iV3 / AR-727CM V3 V110107
ACCESS CONTROL SYSTEM

Web Console
Set up IP Address:

1. Connect the device to a computer, Then turn on your Web Browser


and type "http://192.168.1.127" on IP address to start factory default
webbrowser.

4. Click on [Network Setting] on Main Menu to set up new


IP address.

Factory Default

※ http://192.168.1.127 is the factory default, if the IP address has been


changed, the new IP address may be entered.

a. Type the new


IP address

2. When you type the IP address, you will see the [Current State] page.

b. Click it to update

5. Click on [User Password] on Main Menu to change.

Current IP address

The version of ISP Firmware

Main Menu

Type the new User Name &


Password.

3. Login

Type "User name" & "Password" on


the pop up login window.

※ Factory Default :
User name: admin
Password:(NO need to type)

Copyright by SOYAL Technology Co., Ltd.. All rights reserved.


Serial to Ethernet Device
10/ 100 Base-T V110107

6. Click on [Port 0 Setting] or [Port 1 Setting] on Main Menu to set the port.

Set the [Operation Mode] at the [Server] or the [Client].


At the [Server]: [Remote Port] need to be set [0].
At the [Client]: [Remote Port] need to be set as the server port.
At the [Server]: [Remote IP] need to be set [0.0.0.0].
At the [Client]: [Remote IP] need to be set as the server IP address.
[UART to NET minimum bytes]: Proposes to set more than 900.

Update the ISP Firmware

Step 1: Execute the software [ UdpUpdater.exe] provided by SOYAL.

Step 2: Click on [Load File] to open the Firmware

Step 3: Click on the lastest firmware, and click on [Open].

Step 4: Then follow the steps:


2

1
4

1. Type the IP address and COM Port


2. Click on [Update F/W]
3. Until the screen appears [Program Completed] 3

4. It mean the upgrade is successed, and click on


[Exit] to leave.

Copyright by SOYAL Technology Co., Ltd.. All rights reserved.

You might also like