EN 14103 Determination of Total FAME and Linolenic Acid Methyl Ester in FAME With AC Biodiesel All in One Solution
EN 14103 Determination of Total FAME and Linolenic Acid Methyl Ester in FAME With AC Biodiesel All in One Solution
EN 14103 Determination of Total FAME and Linolenic Acid Methyl Ester in FAME With AC Biodiesel All in One Solution
Figure 1: Linolenic acid (C18:3). Table 1: Peak Identification common fatty acids
www.paclp.com
USA FRANCE GERMANY NETHERLANDS UAE RUSSIA CHINA SINGAPORE SOUTH KOREA THAILAND INDIA
APPLICATION NOTE
www.paclp.com
USA FRANCE GERMANY NETHERLANDS UAE RUSSIA CHINA SINGAPORE SOUTH KOREA THAILAND INDIA
APPLICATION NOTE
According to Biodiesel Specification EN 14214, the The performance of the AC Biodiesel All in One
Iodine value can be calculated from the methyl ester is demonstrated for EN 1403:2011. All
distribution pattern obtained from EN 14103:2011 requirements as stated in the method are met.
results. For each FAME compound a factor to
calculate the iodine value is given according method The AC Biodiesel All in One is also an excellent
prEN 16300. Iodine value, displayed in g iodine / choice to analyze FAME feedstock according to
100 mg, is automatically calculated and reported. ASTM D6584, EN 14105, EN 14110, prEN 16300
and EN 15779. Its innovative dual programmable
oven design ensures optimal availability and
SPECIFICATION CHECK flexibility towards various methods as no column
changes are required when switching
Besides Iodine value, Total ester content and applications and the system is ‘always ready’,
Linolenic Acid Methyl ester content are reported regardless the method that’s needed for the
conform EN 14103:2011 and checked against sample .
specifications in EN 14214. All results obtained are
within the limits specified for this particular sample. The included reference materials & chemicals
and the dedicated reporting makes the AC
Biodiesel All in One very user friendly and easy
to use for fastest adoption in any biodiesel lab.
AC Analytical Controls® has been the recognized leader in chromatography analyzers for gas, naphtha and gasoline streams in crude
oil refining since 1981. AC also provides technology for residuals analysis for the hydrocarbon processing industry. Applications cover
the entire spectrum of petroleum, petrochemical and refinery, gas and natural gas analysis;
ACs Turn-Key Application solutions include the AC Reformulyzer ® , DHA, SimDis, NGA,
Hi-Speed RGA and Customized instruments.
00.00.185 2012/1 - © Copyright 2012 PAC L.P. All rights reserved www.paclp.com