FLUSARC F
SF6 INSULATED METAL ENCLOSED RING MAIN UNITS UP TO 24 KV
C OVERALL DIMENSIONS
Type Lower Terminals Front Terminals
ATTENTION
CAREFULLY LOCK THE VALVE COVER
CAREFULLY LOCK THE VALVE COVER
A (mm) B (mm) C (mm) A (mm) B (mm) C (mm) D (mm)
FUSIBILE
EFFICIENTE
1L
FUSIBILE
INTERROTTO
650 767 680 650 865 680 316
B
1T
I I I
SBLOCCO PORTELLO FUSIBILI
COVER FUSES RELEASE
ENTKUPPLUNG-DERSIGH ERUNGSTUR
DEBLOCAGE DE LA PORTE DES FUSIBLE
O
O
O
O
O
O
783 767 750 783 865 750 316
I I I
1L+1T 783 767 750 783 865 750 316
L1 L2 L3 L1 L2 L3 L1 L2 L3
2L+1T 1065 767 750 1065 865 750 316
2L+2T 1560 767 750 1560 865 750 316
3L 1065 767 680 1065 865 680 316
550/800
3L+1T 1380 767 750 1380 865 750 316
3L+2T 1875 767 750 1875 865 750 316
4L 1230 767 680 1380 865 680 316
4L+1T 1630 767 750 1630 865 750 316
D 630 A 5L 1500 767 680 1500 865 680 316
FLUSARC UNIT
1L Incoming/outgoing switching unit. 3L+1T 3 way switchboard, with outgoing transformer protection.
1T Transformer protection switchboard. 3L+2T 3 way switchboard, with two outgoing transformer
protection.
1L+1T Switching and transformer protection switchboard. 4L 4 way switchboard.
2L+1T Ring switching unit and outgoing transformer protection. 4L+1T 4 way switchboard, with outgoing transformer protection.
2L+2T Ring switching unit with two outgoing transformer 5L 5 way switchboard.
protection.
3L 3 way switchboard.
ELECTRICAL FEATURES
Rated voltage Ur [kV] 12 17,5 24
Power frequency withstand voltage (50/60 Hz 1 min) to earth and between phases [kV] ÷42(*) 38 50
Impulse withstand voltage to earth and between poles Up [kV] 75 95 125
Rated current In [A] 400 - 630 400 - 630 400 - 630
Breaking capacity of active circuits (cos ø0,7) and ring circuits at 0,3Vn Isc [kA] 400 - 630 400 - 630 400 - 630
Breaking capacity of no-load transformers Isc [kA] 25 25 25
Breaking capacity of no-load lines and cables Isc [kA] 25 25 25
Short-time current 1 sec. LBS earthing switch Ik [kA] 12,5...25 12,5...25 12,5...25
Short-time current 3 sec. LBS earthing switch [kA] 12,5...20 12,5...20
Short-time current 1 sec. earthing switch before and after fuses [A] 2 2 2
Making capacity LBS and earthing switch [kA] 31,5...62 31,5...62
Making capacity earthing switch before and after fuses [kA] 5 5 5
Transfer current [A] 1700 1250 800
Internal arc withstand current 1 sec. [kA] 12,5...16 12,5...16 12,5...16
Water proof test 0,3 bar [kV] 50 x 1 min. 24 x 24 ore
(*) Following GB STANDARD (China)
VEI S.p.A. reserves the right of bringing any modification due to technical and commercial reasons at any time.Therefore the information and pictures reported in the present issue are updated until the appro-
val of printing.
c.E50034000 - 05/02
VEI Power Distribution S.p.A.
AUTOSOLE 26862 GUARDAMIGLIO (LO) ITALY
Tel. +39 0377-4171 r.a. - Fax +39 0377-451224
e-mail:
[email protected] - http://www.vei.it