Centrifugal Pumps: Installation and Use Performance Range
Centrifugal Pumps: Installation and Use Performance Range
Centrifugal Pumps: Installation and Use Performance Range
Domestic use
Civil use
40
CHARACTERISTIC CURVES AND PERFORMANCE DATA 50 Hz n= 2900 rpm HS= 0 m
0 5 10 15 20 25 30 35 40 US g.p.m.
0 5 10 15 20 25 30 35 Imp g.p.m.
60 feet
55 CP200
175
50
150
45 CP190
η = 38.5%
40
CP170 125
Head H (metres) 4
CP158
35 CP170M η = 33%
30 100
CP150
η = 44%
η = 34%
η = 44%
25
η = 45.5%
CP130 CP132 75
20
η = 38% η = 54.5%
CP100 50
15
10 η = 41%
25
5
MEI≥ 0.40
0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 l/min
0 1 2 3 4 5 6 7 8 9 m³/h
Flow rate Q 4
MODEL POWER (P2) m³/h 0 0.6 1.2 1.8 2.4 3.0 3.6 4.2 4.8 5.4 6.0 6.6 7.2 7.8 8.4 9.0 9.6
Q
Single-phase Three-phase kW HP l/min 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160
CPm 132 CP 132 0.55 0.75 23 – 22.5 22 21.5 21 20.5 19.5 18.5 17.5 16 14 12
CPm 150 CP 150 0.75 1 IE2 29.5 – 29 28.5 28 27.5 26.5 26 24.5 23 21 18 15
Q = Flow rate H = Total manometric head HS = Suction height Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3B.
41
CP
POS. COMPONENT CONSTRUCTION CHARACTERISTICS
1 PUMP BODY Cast iron with an Epoxy Electro Coating treatment, with threaded ports in compliance with ISO 228/1
2 BODY BACKPLATE Stainless steel AISI 304 (cast iron for CP 170-170M-190-200)
8 ELECTRIC MOTOR CPm: single-phase 230 V - 50 Hz with thermal overload protector incorporated into the winding.
CP: three-phase 230/400 V - 50 Hz.
➠ The three-phase pumps are fitted with high performance motors up to
P2=1.1kW in class IE2 and from P2=1.5kW in class IE3 (IEC 60034-30)
– Insulation: class F
– Protection: IP X4
6 7 6
1 3 2 5 4 8
42
DIMENSIONS AND WEIGHT
f n
DN2
a
h2
h
DN1
h1
w s
n1
ABSORPTION
PALLETIZATION
43