Tutorial 1 - Conduction in Cartiesian System: Thermal Conductivity

Thermal Conductivity tutorial covering 12 problems on heat transfer through various materials: 1) A 20mm thick insulation sheet has a conductivity of 0.0029 W/mK. It has a 10°C temperature difference resulting in a 2m x 2m sheet flux of [VALUE] W and rate of [VALUE] W. 2) A 0.6m2, 2.5cm thick insulator with conductivity 0.2 W/mK conducting 3kW will have a [VALUE]°C temperature difference. 3) A 15cm thick special glass wall with properties [LIST] conducting between 375°C and 85°C will have a heat flow of [VALUE]

Uploaded by

Joe Ford Morales
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
74 views2 pages

Tutorial 1 - Conduction in Cartiesian System: Thermal Conductivity

Thermal Conductivity tutorial covering 12 problems on heat transfer through various materials: 1) A 20mm thick insulation sheet has a conductivity of 0.0029 W/mK. It has a 10°C temperature difference resulting in a 2m x 2m sheet flux of [VALUE] W and rate of [VALUE] W. 2) A 0.6m2, 2.5cm thick insulator with conductivity 0.2 W/mK conducting 3kW will have a [VALUE]°C temperature difference. 3) A 15cm thick special glass wall with properties [LIST] conducting between 375°C and 85°C will have a heat flow of [VALUE]

Uploaded by

Joe Ford Morales
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Tutorial 1 - Conduction in Cartiesian System

Ramesh. K

February 21, 2012

Thermal Conductivity
1. The thermal conductivity of a sheet of rigid, extruded insulation is is reported to be k = 0.0029 mWo K . The
measured temperature difference across a 20mm thick sheet of material is 10o C.

(a) what is the heat flux through a 2m × 2m sheet of insulation.


(b) what is the rate of heat transfer through of insulation.

2. if 3kW is conducted through a section of insulating material 0.6m2 in cross section and 2.5 cm thick and
the thermal conductivity may be taken as 0.2 mWo C , compute the temperature difference across the material.

3. The temperatures on the faces of a plane wall 15 cm thick are 375o C and 85o C. The wall is constructed
kg
of a special glass with the following properties: k = 0.78 mWo C , ρ = 2700 m kJ
3 , cp = 0.84 kg o C . What is the

heat flow through the wall at steady state conditions?

4. A certain thickness has a thermal conductivity of 10 mWo C . What is the thickness necessary to effect a
W
temperature of drop of 500o C for a heat flow of 400 m2.

5. A Truncated cone 30 cm is constructed of aluminium. The diameter of the top is 7.5cm, and the diameter
at the bottom is 12.5cm. The lower surface is maintained at 93o C; the upper surface at 5400 C. The outer
surface is insulated. Assuming one-dimensional heat flow, what is the rate of heat transfer in watts.

6. what is the thickness required by masonary wall having thermal conductivity of k = 0.75 mWo K , if the heat
rate is to be 80% of the heat rate through a composite structure wall having a thermal conductivity
k = 0.25 mWo K and thickness of 100mm? Both walls are subjected to same temperature difference.

7. The inner and outer surface temperatures of a glass window 5mm thick are 15o C and 5o C. What is the
heat loss through a window that is 1m × 3m on a side? The thermal conductivity of of glass is 1.4 mWo K

8. Find the heat flux and temperature distribution in an infinite slab of thickness ‘b‘ whose thermal conduc-
tivity varies linearly with the temperature in the form k = k0 (1 + cT ), where k0 and ‘c‘ are constants.
Sketch the temperature distribution when c > 0 and c < 0

9. The thermal conductivity of a plane wall varies as k = k0 (1 + bT + cT 2 ). If the wall thickness is L and
the surface temperature are maintained at T1 &T2 . Show  that the heat flux ‘q‘ through the wall is given
by q = ko (T 1−T
L
2)
1 + b
2
[T 1 + T 2] + c
3
[T1
2
+ T T
1 2 + T 2
2 .]

1
10. The temperature distribution across a wall of 1m thick at a certian instant of time is given as T (x) = a+bx+
o o
cx2 where T is in o C and x in m while a = 900 o C , b = −300 mC , c = −50 mC2 . A uniform heat generation,
W kg W
q̇ = 1000 m 2
3 , is present in the wall of area 10m , having the properties ρ = 600 m3 , k = 40
mK̇
, cp = 4 kgkJK̇

• Determine the rate of heat transfer that is entering the wall (x = 0) and leaving the wall(x = 1).
• Determine the rate of change of engergy storage in the wall.
• Determine the rate of temperature change at (x = 0.0, 0.25, 0.5, 0.75)

11. Assume steady-state, one-dimensional heat conduction through the symmetrical shape shown in Figure 1,
assuming that there is no internal heat generation, derive an expression for the thermal conductivity k(x)

Figure 1: Tapered Section

for these conditions

A(x) = (1 − x)
T (x) = 300(1 − 2x − x3 ), q = 6000W

where A in m2 , x in m and T in Kelvins

12. Consider a plane wall as shown in Figure 2 of 100mm thick and of thermal conductivity 100W
m.K
. Steady
00
state conditions are known to exist with T1 = 400K, T2 = 600K. Determine the heat flux q and the
temperature gradient dT
dx
for the coordinate system shown in below

Figure 2: Plane wall