Shear Tab Connection Sd-01: Detail-2 Detail-1

This document provides details for a shear tab connection (SD-01) between steel beams and columns. The connection uses 3/4" A325 bolts in standard holes with a 1" horizontal slot in the shear tab. It specifies materials, dimensions, minimum web thicknesses, and capacities for beam-to-beam and beam-to-column configurations up to a capacity of 127 kips. Notes provide information on welding, cope dimensions, and capacity reduction if the actual web thickness is less than required.

Uploaded by

Prakash Singh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
77 views1 page

Shear Tab Connection Sd-01: Detail-2 Detail-1

This document provides details for a shear tab connection (SD-01) between steel beams and columns. The connection uses 3/4" A325 bolts in standard holes with a 1" horizontal slot in the shear tab. It specifies materials, dimensions, minimum web thicknesses, and capacities for beam-to-beam and beam-to-column configurations up to a capacity of 127 kips. Notes provide information on welding, cope dimensions, and capacity reduction if the actual web thickness is less than required.

Uploaded by

Prakash Singh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

SHEAR TAB CONNECTION SD-01

4"x3/8" THK SHEAR TAB


4"x3/8" THK SHEAR TAB
ASTM GRADE A36
212" FY =36 ksi, FU=58 ksi 212" ASTM GRADE A36
1 " FY =36 ksi, FU=58 ksi
1" 2 1"
SUPPORTED BEAM SUPPORTED BEAM
1/8 ASTM GRADE A992 ASTM GRADE A992
(MIN) FY =50 ksi , FU=65 ksi FY =50 ksi , FU=65 ksi
112"

112"
3"

3"
SUPPORTING BEAM

FY=50 ksi , FU=65 ksi


ASTM GRADE A992
'NR' BOLT ROWS

'NR' BOLT ROWS


@ 3" SPACING

@ 3" SPACING
1/4 1/4
1/4 1/4
112"

112"
Ø 3/4 A325 N-TYPE BOLTS 11 2" 11 2" Ø 3/4 A325 N-TYPE BOLTS
WITH STD HOLES IN MEMBER WITH STD HOLES IN MEMBER
AND 13/16"x1" HORIZONTAL AND 13/16"x1" HORIZONTAL
SLOT IN SHEAR TAB SLOT IN SHEAR TAB
11 2" 112"
W-COLUMN ASTM GRADE A992
FY =50 ksi , FU=65 ksi
HSS-COLUMN ASTM A500 GRADE-B
FY =46 ksi , FU=58 ksi

DETAIL-1 DETAIL-2
(BEAM TO BEAM) (BEAM TO HSS/W-COLUMN)

NOTE :-
1. WELD ELECTRODE CLASS E70XX, FW = 70 ksi
2. ALL DESIGN AND DETAILS ARE CONFIRMING TO AISC 13TH EDITION MANUAL, ASD DESIGN.
3. TOP / TOP AND BOTTOM COPE LENGTH SHALL BE < 0.5 TIMES OF THE SUPPORTED BEAM DEPTH
4. COPE DEPTH AT TOP / TOP AND BOTTOM SHALL BE < 0.2 TIMES THE SUPPORTED BEAM DEPTH
5. IF THE ACTUAL WEB THICKNESS IS < THE MIN. REQ'D THICKNESS THEN,
CAPACITY = CONNECTION CAPACITY X ACTUAL WEB THICK / REQ'D WEB THK

MIN. REQ'D SUPPORTED WEB THICKNESS TO


CONNECTION DEVELOPE CONNECTION CAPACITY (in)
MARK NO. NR
CAPACITY (kip)
NO COPE SINGLE COPE DOUBLE COPE

SD-01/S2ST 2 21.2 0.181 0.219 0.256

SD-01/S3ST 3 31.8 0.181 0.230 0.256

SD-01/S4ST 4 42.4 0.181 0.236 0.256

SD-01/S5ST 5 53.0 0.181 0.240 0.256

SD-01/S6ST 6 63.6 0.181 0.242 0.256

SD-01/S7ST 7 74.2 0.181 0.244 0.256

SD-01/S8ST 8 84.8 0.181 0.246 0.256

SD-01/S9ST 9 95.4 0.181 0.247 0.256

SD-01/S10ST 10 106.0 0.181 0.248 0.256

SD-01/S11ST 11 117.0 0.182 0.249 0.257

SD-01/S12ST 12 127.0 0.181 0.249 0.255

You might also like