0% found this document useful (0 votes)
109 views

Vessel Side Shell Check Calculations

This document provides calculations to check the local strength of a vertically stiffened bulkhead on a barge or vessel under a given vertical load. It calculates the bearing compressive stress on the bulkhead and compares it to the allowable stress to check for adequate bearing strength. It also calculates the effective cross-sectional properties of the vertical stiffeners including area, neutral axis, and moment of inertia to check the axial capacity of the stiffeners is sufficient to resist the distributed load from the bulkhead. Input parameters describing the bulkhead geometry, stiffener details, and material properties are provided to perform the calculations.

Uploaded by

Shahir Meledath
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
109 views

Vessel Side Shell Check Calculations

This document provides calculations to check the local strength of a vertically stiffened bulkhead on a barge or vessel under a given vertical load. It calculates the bearing compressive stress on the bulkhead and compares it to the allowable stress to check for adequate bearing strength. It also calculates the effective cross-sectional properties of the vertical stiffeners including area, neutral axis, and moment of inertia to check the axial capacity of the stiffeners is sufficient to resist the distributed load from the bulkhead. Input parameters describing the bulkhead geometry, stiffener details, and material properties are provided to perform the calculations.

Uploaded by

Shahir Meledath
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

McDermott PREP.

BY_________
Middle East Inc. CHKD. BY_________
Eastern Hemisphere
OFFSHORE OPERATIONS

BULKHEAD STRENGTH CHECK (Vertically Stiffened Panels)


File: 23.0 Bhd-long-stiff.xmcd (Version 1.1)

PROJECT :- SIDE SHELL CHECK


1.0 SCOPE

This worksheet verifies the local strength of a vertically stiffened bulkhead of the barge/vessel in bearing and
the axial capacity of the vertical stiffeners of the bulkhead, for a given load.

The following are the considerations in this regard.

1. The check for the global strength of the bulkhead is not a part of this worksheet.
2. The local strength of the bulkhead in bearing is checked considering the bulkhead to be consisting of
long rectangular uniaxially stiffened panels subjected to in-plane end compression.
References:

[1] API BUL 2V, Bulletin on Design of Flat Plate Structures, 3rd edition, June 2004
[2] Manual of Steel Construction - ASD- 9th Edition
[3] API RP 2A - WSD (21st Edition)

ORIGIN  1
kN := 1000newton
6
MPa  10  Pa

Fig.-1
2.0 INPUTS
2.1 Forces

P := 687  kN _Vertical load on the bulkhead [see Fig.-1] (MAX COMP/ TENSION)

2.2 Barge Bulkhead Data

s := 600 mm _Spacing of vertical stiffeners

l := 3.81 m _Effective span of stiffeners [see Fig.-1]

t p := 9  mm _Thickness of bulkhead plating

File : stringer edge-Side shell check- Page 1 of 5


Bhd-long_stiff.xmcd Date: 06-Sep-20
McDermott
Middle East Inc.
Eastern Hemisphere
OFFSHORE OPERATIONS

type := 0 _Type of stiffener cross section, put 0 for 'T' sections and 1 for Angle sections

ns := 1 _Total no of effective stiffeners below the skid + brackets

K := 0.65 _ Effective length factor K=0.65 for fixed-fixed


of the columns K=0.80 for fixed-pinned
made of vertical K=1.00 for pinned-pinned
stiffeners and plating K=2.10 for fixed-free
K=2.00 for pinned-free

k := 4 _Buckling coefficient (To be taken as 4 for simply


supported plate edges, subjected to axial load
only. For other boundary
conditions, k is to be determined from the
attached Fig.-1 [figure 3.4 of API BUL 2V: Section
3.2.2.a]
Note :-

· a and b as shown in Fig.-2 denotes the dimensions of the stiffened


panels.
· a>b
· A, B, C & D denotes the different boundary conditions of the
stiffened panels as shown. c = clamped, ss = simply supported

2.3 Wing Bracket Data


A := 0 mm _Dimension A on deck
t wb := 0mm _Thickness of bracket
Wskid := 300 mm _Width of skid
Fig.-2
2.4 Cross Sectional Properties of the Vertical Stiffener (put '0' wherever not applicable)

t w := 10 mm _Thickness of web (plate 2)

dw := 490 mm _Depth of web (plate 2)

bf := 180 mm _Breadth of 'T' or 'Angle' flange (equivalent) (plate 3)

t f := 10 mm _Thickness of 'T' or 'Angle' flange (equivalent) (plate 3)

2.5 General

Fy := 235MPa _Material yield stress

E := 205000 MPa _Modulus of elasticity

ν := 0.3 _Poisson's ratio

μ := 1.0 _Allowable increase factor on stress (= 1.0 if no increase is allowable )

- END OF INPUT -

File : stringer edge-Side shell check- Page 2 of 5


Bhd-long_stiff.xmcd Date: 06-Sep-20
McDermott
Middle East Inc.
Eastern Hemisphere
OFFSHORE OPERATIONS

3.0 CALCULATION

3.1 Check for Local Bearing Strength Criteria

spread := Wskid + 2  A _Width of skid +brackets

2 2
k π  E tp 
f :=   _Nominal stress when the plate is compressed
(
12 1 - ν  
2 s ) in X-direction alone (axially) : Ref. [1]

(
f := if f > 0.9Fy, 0.9Fy , f ) _Allowable bearing compressive stress f = 166.753  MPa

P
σbear := _Calculated bearing compressive stress σbear = 254.444  MPa
spread tp  μ

(
Result_1 := if σbear < f , "OK" , "NOT OK" ) Result_1 = "NOT OK"

3.2 Check for Axial Compression Capacity of the Vertical Stiffeners


Vertical stiffeners are considered to form a column section in combination with the attached plating. The load on
the bulkhead is considered to be distributed between a number of such column sections. The capacity of each
such section is estimated here.

Effective flange width of Attached Plating _Ref. ABS Mobile Offshore Drilling Units (2014)

beff := min( 33 % l , s) _Effective width of attached plating beff = 600 mm

n := 3 _No. of elements of the column section

YD := tp + d w + t f _Depth of the section YD = 509 mm

(
ZD := max b eff , bf ) _Width of the section ZD = 600 mm

i := 1 .. n

Section Properties

(
z3 := if type = 0 , b eff  0.5 , b eff  0.5 + b f  0.5 ) _z-coordinate of bottom flange z3 = 300 mm
(depending on the type of cross section
of stiffener as mentioned in Section 2.2)

Element width, depth, z & y distances from Y & Z axes respectively:

b := d := y := z :=
i i i i

b eff tp d w + 0.5 tp + t f b eff  0.5


tw dw ( )
0.5 d w + t f b eff  0.5
bf tf 0.5 tf z3

File : stringer edge-Side shell check- Page 3 of 5


Bhd-long_stiff.xmcd Date: 06-Sep-20
McDermott
Middle East Inc.
Eastern Hemisphere
OFFSHORE OPERATIONS

 ( b j  dj )
4 2
AX := _Area of cross section AX = 1.21  10  mm
j =1

 ( b j  d j  zj )
j =1
zna := _Neutral axis from y-axis zna = 300 mm
AX

 n b )  (d )
(
3
n
 b  d  z  + j  _Moment of inertia about N.A
( )
j
 
2 2
IY := - AX zna 8 4
  j j j  12  parallel to y-axis IY = 1.669  10  mm
j = 1 j =1 
n

 (bjdjyj)
j =1
yna := _Neutral axis from z-axis yna = 329.157  mm
AX

 n b ) (d ) 
(
3
n
 b  d  y  +  - AX y 2
( )
j j
 
2 8 4
IZ := _Moment of inertia about N.A IZ = 4.802  10  mm
  j j j  12  na
parallel to z-axis
j = 1 j = 1 

IY
RY := _Radius of gyration about y-axis RY = 117.446  mm
AX

IZ
RZ := _Radius of gyration about z-axis RZ = 199.214  mm
AX

r := if ( RZ > RY , RY , RZ) _Minimum radius of gyration r = 117.446  mm

Allowable Axial Load for Stiffeners

nst := round 
spread 
 _Theoretical number of stiffeners nst = 1
 s  mobilized below the load

(
nstiff := min n st , ns ) _Number of effective stiffeners nstiff = 1

0.5
 2  π2 E 
Cc :=
 Fy 
 

File : stringer edge-Side shell check- Page 4 of 5


Bhd-long_stiff.xmcd Date: 06-Sep-20
McDermott
Middle East Inc.
Eastern Hemisphere
OFFSHORE OPERATIONS

  K l 
2
  r  
1 -   F
 2 
y
2  Cc
Fa :=
  if
K l
< Cc
3 r _Allowable axial compressive stress Fa = 134.363 MPa
K l 
3   
 K l 
 
Eq. - E2.1 , Ref [2], Section 3.2.2,
 5  +  r  -  r Ref [3]
3
  8  Cc
8 Cc
3

2
12 π  E
otherwise
2
K l 
23  
 r 
3
Pcri := Fa AX _Allowable axial load Pcri = 1.626  10  kN

P
Pactual := _Calculated axial load per stiffener Pactual = 687 kN
n stiff  μ

4.0 SUMMARY OF RESULTS

(
Result_2 := if Pactual < Pcri , "OK" , "NOT OK" ) Result_2 = "OK"

File : stringer edge-Side shell check- Page 5 of 5