Bulletin No.: Pulsapro 900-Iom-2009 Rev. G Installation Operation Maintenance Instructions
Bulletin No.: Pulsapro 900-Iom-2009 Rev. G Installation Operation Maintenance Instructions
Bulletin No.: Pulsapro 900-Iom-2009 Rev. G Installation Operation Maintenance Instructions
G
INSTALLATION
OPERATION
MAINTENANCE
INSTRUCTIONS
Pulsafeeder, Inc.
2883 Brighton Henrietta Town Line Road
Rochester, New York, 14623
Email: [email protected]
Manufacturers of Quality Pumps, Telephone: ++1 (585) 292-8000
Controls and Systems Fax: ++1 (585) 424-5619
pulsafeeder.com
PulsaPro Series Guarantee
Should you experience a problem with your Pulsafeeder pump, first consult the troubleshooting
guide in your operation and maintenance manual. If the problem cannot be solved, please contact
your local Pulsafeeder Sales Representative, or our Technical Services Department for further
assistance.
Trained technicians are available to diagnose your problem and arrange a solution. Solutions
may include purchase of replacement parts or returning the unit to the factory for inspection and
repair. All returns require a Return Authorization number to be issued by Pulsafeeder. Parts
purchased to correct a warranty issue may be credited after an examination of original parts by
Pulsafeeder. Warranty parts returned as defective which test good will be sent back freight
collect. No credit will be issued on any replacement electronic parts.
Any modifications or out-of-warranty repairs will be subject to bench fees and costs associated
with replacement parts.
In addition, Pulsafeeder guarantees its PulsaPro Series drive assemblies for a period of five
years from the date of shipment. All other material and workmanship are fully covered for a
period of one year. Any parts found to be defective within the above time span will be replaced
free of charge, F.O.B. our factory.
Equipment or accessories manufactured by others but purchased through Pulsafeeder, such as
electric motors, are guaranteed only to the extent of the original manufacturer.
Damages incurred from misuse, abuse, and/or improper protection during storage will be cause to
void this guarantee. Erosion, corrosion, or improper application of the equipment or related
piping by the buyer or any third party is also excluded.
The above guarantee is in lieu of any other guarantee, either expressed or implied. We make no
warranty of fitness or merchantability. No agent of ours is authorized to make any warranty other
than the above.
Safety Considerations:
1. Read and understand all related instructions and documentation before attempting to install or
maintain this equipment
2. Observe all special instructions, notes, and cautions.
3. Act with care and exercise good common sense and judgment during all installation, adjustment,
and maintenance procedures.
4. Ensure that all safety and work procedures and standards that are applicable to your company and
facility are followed during the installation, maintenance, and operation of this equipment.
ii
Table of Contents
1. INTRODUCTION ..................................................................................................................................... 1
1.1 General Description ................................................................................................................ 1
2. PRINCIPLES OF OPERATION................................................................................................................... 1
2.1 Overall Operation .................................................................................................................... 1
2.2 Component Location............................................................................................................... 2
2.2.1 Reagent Head Assembly................................................................................................. 3
2.2.2 Pump Head/Piston Assembly ......................................................................................... 4
2.2.3 Control Assembly ............................................................................................................ 6
2.2.4 Gear Reducer Assembly ................................................................................................. 7
3. EQUIPMENT INSPECTION ....................................................................................................................... 8
4. STORAGE INSTRUCTIONS ...................................................................................................................... 8
4.1 Short Term ............................................................................................................................... 8
4.2 Long Term ................................................................................................................................ 8
5. INSTALLATION ...................................................................................................................................... 9
5.1 Location .................................................................................................................................... 9
5.2 Mounting .................................................................................................................................. 9
5.3 Piping System .......................................................................................................................... 10
5.3.1 Suction Pressure Requirements .................................................................................... 11
5.3.2 Discharge Pressure Requirements ................................................................................ 11
6. EQUIPMENT STARTUP ........................................................................................................................... 12
6.1 Lubrication ............................................................................................................................... 12
6.1.1 Oil Capacities ................................................................................................................... 12
6.1.2 Oil Fill ................................................................................................................................ 14
6.1.3 Oil Changes ...................................................................................................................... 16
6.2 Startup ...................................................................................................................................... 17
6.2.1 Output Adjustment .......................................................................................................... 17
6.2.2 Priming the Pump Head .................................................................................................. 18
6.2.3 Priming the Reagent Head .............................................................................................. 18
6.2.4 Motor Rotation ................................................................................................................. 19
6.2.5 Calibration ........................................................................................................................ 20
7. MAINTENANCE ...................................................................................................................................... 21
7.1 Wet End Removal, Inspection, and Reinstallation ............................................................... 22
7.2 Re-Priming the Pump Head .................................................................................................... 24
7.2.1 Re-Filling the Hydraulic System..................................................................................... 25
7.2.2 Re-Priming the Hydraulic System .................................................................................. 25
7.3 Check Valves ........................................................................................................................... 26
7.3.1 Check Valve Removal ..................................................................................................... 27
7.3.2 Ball Valve – Inspection and Repair ................................................................................ 27
7.3.3 Disk Valve – Inspection and Repair ............................................................................... 27
7.3.4 Check Valve Reinstallation ............................................................................................. 28
7.4 Hydraulic Performance Valve (HPV) ...................................................................................... 29
7.4.1 HPV Removal and Replacement .................................................................................... 30
7.5 Hydraulic Bypass Valve (HBV) ............................................................................................... 31
7.5.1 PTP (Push To Purge) Valve ............................................................................................ 32
7.5.2 PTP Removal, Cleaning, and Reinstallation ................................................................. 33
7.5.3 Piston Seal ....................................................................................................................... 34
7.5.4 Piston Removal ................................................................................................................35
7.5.5 Piston Seal Reinstallation ............................................................................................... 35
7.6 Oil Seals ................................................................................................................................... 37
7.6.1 General Description......................................................................................................... 37
7.6.2 Motor Adaptor Oil Seal Removal and Replacement..................................................... 38
7.7 Stroke Control Assembly .......................................................................................................40
7.7.1 Stroke Control Assembly Maintenance ......................................................................... 40
7.8 Motor Removal and Reinstallation ........................................................................................ 41
8. REPLACEMENT PARTS .......................................................................................................................... 42
8.1 PulsaPro Series KOPkit Program .......................................................................................... 42
iii
8.2 Ordering KOPkits or Parts ...................................................................................................... 42
9. PULSALARM LEAK DETECTION PUMP HEAD ASSEMBLY ....................................................................... 43
9.1 PULSAlarm Leak Detection Diaphragm ................................................................................ 43
9.2 Leak Detection – Setup for Pressure..................................................................................... 44
9.3 Pressure System Set-up and Priming ................................................................................... 45
9.4 PULSAlarm Leak Detection Diaphragm Maintenance ......................................................... 47
9.4.1 Leak Detection Diaphragm Removal ............................................................................. 48
9.4.2 Inspection ......................................................................................................................... 48
9.4.3 Leak Detection Diaphragm Reinstallation .................................................................... 48
10. TROUBLESHOOTING CHART................................................................................................................... 49
APPENDIX I – PIPING CALCULATIONS ........................................................................................................... 51
Suction Head Requirements .............................................................................................................. 51
System Back Pressure ........................................................................................................................ 53
Nomenclature....................................................................................................................................... 53
APPENDIX II – OIL SPECIFICATIONS .............................................................................................................. 54
PULSAlube Universal 1HG ................................................................................................................. 54
APPENDIX III – BOLT TORQUE RECOMMENDATIONS/NOZZLE LOADS ............................................................. 55
Reagent Head and Tie-Bar .................................................................................................................. 55
Pump Head Bolts ................................................................................................................................. 55
Nozzle Loads........................................................................................................................................ 56
APPENDIX IV DIMENSIONAL DRAWINGS ........................................................................................................ 57
APPENDIX V EC DECLARATION OF CONFORMANCE ...................................................................................... 62
Conventions
For the remainder of this bulletin, the following Conventions are in effect.
A WARNING DEFINES A CONDITION THAT COULD CAUSE DAMAGE TO BOTH
THE EQUIPMENT AND THE PERSONNEL OPERATING IT. PAY CLOSE
ATTENTION TO ANY WARNING.
Notes are general information meant to make operating the equipment easier.
Tips have been included within this bulletin to help the operator run the
equipment in the most efficient manner possible. These “Tips” are drawn from
the knowledge and experience of our staff engineers, and input from the field.
iv
1. Introduction
1.1 General Description
Diaphragm Metering pumps are positive displacement reciprocating pumps that combine the
high efficiency of the plunger pump with a sealed diaphragm that prevents product leakage.
Each pump consists of a power end and a process end separated by a hydraulically operated
diaphragm. Individual pumps will vary in appearance due to various liquid ends, accessories,
and multiplexing - however, the basic principles of operation remain the same.
2. Principles of Operation
2.1 Overall Operation
Figure 1
A piston reciprocates within an accurately sized cylinder at a preset stroke length, displacing
an exact volume of hydraulic fluid. The hydraulic fluid acts against a sealed diaphragm,
which pumps the chemicals.
The piston and associated mechanisms are enclosed by a chamber called the Pump Head or
intermediate housing. This also acts as a hydraulic oil reservoir.
The diaphragm separates the hydraulic oil from the product pumped. The diaphragm moves
in exact response to the piston displacement. The diaphragm does no work, and acts only as a
separator.
The displacement of the oil is translated into an equal displacement of the chemical being
pumped. Therefore, piston retraction causes the product to enter through the suction check
valve. Piston advance causes the discharge of an equal amount of the product through the
discharge check valve.
1
2.2 Component Location
Figure 2
2
2.2.1 Reagent Head Assembly
The term Reagent Head Assembly refers to the pump components that come into direct
contact with the process fluid (or Reagent). The typical Reagent Head Assembly consists of
the following components:
a) Reagent Head
b) Diaphragm
c) Suction Check Valve
d) Discharge Check Valve
Figure 3
3
2.2.2 Pump Head/Piston Assembly
The pump head/piston assembly is installed on the intermediate housing. This assembly contains
the hydraulic system which consists of the pump head, cylinder, piston assembly, and four
hydraulic valves:
a) Push-To-Purge (PTP)
b) Hydraulic Performance Valve (HPV)
c) Hydraulic Makeup Valve (HMV)
d) Hydraulic Bypass Valve (HBV)
PTP
HMV
Detail
HPV A
Detail A
HBV
Figure 4
4
2.2.2.1 Push to Purge (PTP)
The Push to Purge (PTP) valve is located at the top of the Pump Head. It
automatically removes air entrained in the hydraulic system. Pressing down on the
button at the top of the PTP overrides its automatic operation. This allows a small
amount of hydraulic fluid to bleed from the pump head to the reservoir every stroke.
Activating the PTP in this manner helps determine if the pump head is properly
primed and diaphragm integrity is maintained.
2.2.2.2 Hydraulic Performance Valve (HPV)
The Hydraulic Performance Valve (HPV) automatically maintains the hydraulic oil
that “connects” the piston to the diaphragm. During normal operation small amounts
of hydraulic fluid is lost past the piston seal and PTP. This causes the diaphragm to
move progressively closer to the button on the HPV valve (see Figure 4, Detail A).
Over time, the diaphragm will come into contact with this button. When this occurs, it
will push the HPV valve open allowing lost hydraulic fluid to be replenished.
2.2.2.3 Hydraulic Makeup Valve (HMV)
The Hydraulic Makeup Valve (HMV) works in conjunction with the HPV to assure
hydraulic oil flows in one direction (into the diaphragm/piston chamber) at the correct
pressure.
2.2.2.4 Hydraulic Bypass Valve (HBV)
The Hydraulic Bypass Valve (HBV) protects the pump from over-pressurizing by
relieving any excess pressure. It is typically set at 110% of the Pump’s discharge
pressure.
5
2.2.3 Control Assembly
The output of the PulsaPro 900 can be controlled by changing how far the piston moves
with each pump stroke. The Piston is attached to a rotating cam with a connecting rod. The
Control Assembly allows the throw of the cam to be adjusted (see Figure 5). The assembly
consists of the following parts:
e) Hand wheel
f) Threaded Shaft
g) Inner Stroke Adjust Shaft
h) Large and Small Plunger
i) Inner Cam
2.2.3.1 Operation
The output of the pump is varied by turning the Hand Wheel. The Hand Wheel turns a
threaded shaft. Depending on the direction of rotation, this either pulls the inner stroke
adjustment shaft towards the hand wheel or pushes it away. The inner stroke shaft includes
two opposite faces that are machined on an angle. A Large and Small Plunger ride on these
opposite faces. An Inner Cam rides over the plungers. As the position of the Inner Stroke
Adjustment Shaft changes, the Plungers shift from one side to the other causing the throw of
the cam to change.
Figure 5
The stroke length setting is denoted by a 0 – 100% scale with 2.5% increments. The scale is
located on the top part of the stroke control housing under a clear sealed cover.
6
2.2.4 Gear Reducer Assembly
PulsaPro 900 pumps are driven by a standard C-face electric motor mounted to an
adaptor that completely encloses a coupling. The motor drives a worm gear reduction that
turns an eccentric shaft assembly – converting the rotary motion into reciprocating motion.
Figure 6
A single drive assembly can drive up to four Pump/Reagent Head assemblies. This is
referred to as multiplexing.
Figure 7
Whenever pumps are multiplexed the eccentric shafts are positioned to place a uniform load
on the drive. Before full disassembly always note the relative positions of the eccentric shafts
to each other so they can be reassembled back in the same orientation.
7
3. Equipment Inspection
Check all equipment for completeness against the order and for any evidence of shipping
damage. Shortages or damage should be reported immediately to the carrier and your
PulsaPro Representative.
4. Storage Instructions
4.1 Short Term
Storage of PulsaPro Series pumps for up to 12 months is considered short-term. The
recommended short-term storage procedures are:
a) Store the pump indoors at room temperature in a dry environment.
b) Prior to startup, inspect the pump head, and gearbox. Replenish oil as required to
maintain operating levels. If water or condensation is present, change oil as described in
the Equipment Startup section.
c) Prior to startup, perform a complete inspection and then start up in accordance with the
instructions in this manual.
8
5. Installation
5.1 Location
When selecting an installation site or designing a skid package, consideration should be given to
access for routine maintenance.
PulsaPro 900 pumps are designed to operate indoors and outdoors. At a minimum, a
covering to protect the pump from direct weather and sunlight is required. External heating
and/or the use of synthetic lubricants for the gearbox is recommended if ambient temperatures
below 20C (0F) or above 40C (104F) are anticipated. Check with the factory if you are
concerned with the suitability of the operating environment.
5.2 Mounting
The pump must be rigidly bolted to a solid and flat foundation to minimize vibration, which can
loosen connections. Bolt each base with a minimum of 1” diameter studs with flat and lock
washers in 4 locations per base (note: the quad configurations include 2 bases). The pump must
be level within 2. This will assure that the oil is maintained at the proper level and that the
check valves can operate properly.
mm
[inch]
Figure 7
9
5.3 Piping System
DISCHARGE
RETURN TO TANK
Figure 8A
10
4. A separate system relief valve to protect piping and process equipment, including the pump,
from excess process pressures.
a) The hydraulic bypass valve (HBV) in the pump is not intended to protect the system.
Piping weight must not be supported by valve housings or other portions of the reagent head, as
the resulting stresses can cause leaks. If appropriate, provide for thermal expansion and
contraction so that no excess force or movement is applied to the pump.
In piping assembly, use a sealing compound chemically compatible with the process material.
Users of sealing tape are cautioned to ensure that the entering pipe thread ends are not taped,
and that tape is removed from previously-used threads prior to re-use. Both new and existing
piping should be cleaned, preferably by flushing with a clean liquid (compatible with process
material) and blown out with air, prior to connection to the pump.
DISCHARGE PRESSURE MUST NEVER EXCEED THE HYDRAULIC BYPASS VALVE (HBV)
SETTING ON THE NAMEPLATE. EXCESSIVE DISCHARGE PRESSURE COULD IMPAIR
PERFORMANCE, DAMAGE THE PUMP AND VOID THE WARRANTY.
6.1 Lubrication
PULSAPRO 900 PUMPS USE PULSALUBE UNIVERSAL 1HG OIL AS STANDARD FOR THE
PUMP HEAD AND GEARBOX. USE OF ALTERNATIVE LUBRICANTS COULD IMPAIR
PERFORMANCE, DAMAGE THE PUMP AND VOID THE WARRANTY.
Pulsalube Universal 1HG is standard oil supplied with all pumps unless
specified. Temperatures +40 – 280 °F
12
13
6.1.2 Oil Fill
The pump is shipped from the factory filled to the proper level with PULSAlube Universal
or Ultra. The oil is held within two main reservoirs – the Gear Box (located on the motor
end of the pump) and the Pump Head (located on the process fluid end of the pump). The
two reservoirs are connected to allow lubricant to flow between them to assure a constant oil
level across the entire pump.
Two sight glasses provide a visual confirmation of oil level. One is located in the Pump
Head next to the HBV valve. The second is located in the Gearbox below the motor on the
centerline. The construction and operating conditions of the pump can cause the oil level to
go up or down during operation – this is normal. The level should be set to the center of the
sight glass. During operation the level can increase or decrease from this position, but should
always be visible within the window. For reliable measurements shut the pump off, set the
Stroke Adjustment to 0% stroke and wait approximately 5 minutes before reading the sight
glass levels.
The oil fill is located on the top of the gearbox opposite the motor (see Figure 9A). To fill,
remove the cover and add PULSAlube Universal or Ultra. Because this one fill location
supplies two reservoirs, it is necessary to wait several minutes for the level to stabilize across
the entire pump.
During normal operation, the worm gear running behind the sight glass in the gearbox
will cause oil to cover the glass completely. This is normal and does not reflect the true
measure of oil level. Turn the pump off and set the Stroke Adjustment to 0% to check
the oil level properly.
Oil Fill
Rear
Sight
REAR SIGHT GLASS
Glass
Rear Sight
Glass Proper Oil
Level with
Pump Off
FRONT SIGHT
GLASS
Maximum
Oil Level
Minimum
Oil Level
15
6.1.3 Oil Changes
6.1.3.1 Service Level Definition
The recommended oil change intervals are dependent upon the operating environment and
level of pump usage, classified as follows:
Normal service
Clean/dry atmosphere, an ambient operating temperature of 0C to 40C (32F to
104F), and up to 2,000 annual operating hours.
Severe Service
Humid atmosphere, an ambient operating temperature below 0C (32F) or above
40C (104F), and over 2,000 annual operating hours.
16
6.2 Startup
6.2.1 Output Adjustment
When starting up the pump for the first time, it is best to set the stroke adjustment to
0% output and then slowly increase the setting to 100%. This allows you to react to
any leaks that may be present in the piping system before they become severe.
The PulsaPro 900 uses a hand wheel for manual stroke adjustment. It is mounted on the
rear of the stroke adjust housing (refer to Figure 10). The hand wheel can be adjusted at any
point from 0 to 100%. It includes a stroke lock mechanism. Before making an adjustment
pull out the stroke lock handle and rotate it ¼ turn to hold it in the disengaged position. With
the stroke lock disengaged, crank the hand wheel in either direction to adjust the stroke length
to the desired setting – do not go below the 0% or above the 100% marks. After you have
completed your stroke length setting, re-engage the stroke lock by turning the stroke lock
handle ¼ turn.
Please be sure the stroke lock is then engaged during pump operation to prevent drift.
Stroke
Adjustment
Stroke
Lock
Figure 10
17
6.2.2 Priming the Pump Head
All pumps are shipped with a fully primed hydraulic system. However, during shipping,
handling and storage some air may accumulate in the hydraulic system resulting in reduced
performance. Generally this air will be automatically purged after a short run-in period. If
necessary, rapid purging may be accomplished by:
1. Fully depressing and holding the button on top of the PTP valve while the pump is
operating at any stroke length setting above 30%.
2. With the PTP button depressed, oil should begin to flow out of the small diagnostic port.
PTP
DIAGNOSTIC
PORT
DIAGNOSTIC WINDOW
3. Hold the valve down for several seconds after the oil is clear of bubbles to ensure a good
prime.
If the pump fails to prime refer to Section 7.2.1, Re-Priming the Pump Head.
18
6.2.4 Motor Rotation
Verifying the proper rotation of the motor
a) To verify the correct shaft rotation of the motor you can remove the 3 screws to the
access cover or remove the large pipe plug on the side of the motor adaptor housing.
This will allow you visual sight of the motor coupling to verify rotation.
b) Another way to verify the proper motor rotation is to observe the rotation of the fan
on the motor.
Observing from the rear of the pump the Proper rotation of the input shaft of the
Pro 900 pump is CLOCKWISE. Please also refer to the arrow that is cast into the
gearbox for proper rotation.
19
6.2.5 Calibration
All metering pumps must be calibrated to accurately specify stroke length settings to achieve
required flow rates.
Figure 11
A typical calibration chart is shown in Figure 11. Although output is linear with respect to
stroke length setting, an increase in discharge pressure decreases output uniformly, describing a
series of parallel lines, one for each pressure (only two are shown in the figure).
The theoretical output flow rate at atmospheric pressure is based on the displacement of the
hydraulic piston (the product of the piston cross-sectional area and stroke length) and the
stroking rate of the pump.
Whenever possible, calibration should be performed under actual process conditions (i.e., the
same or a similar process liquid at system operating pressure).
To assure a sound hydraulic system, run the pump for 15-20 minutes prior to calibration. This
will allow the PTP (automatic bleed) valve to purge any air from the system.
Allowing the pump to run for several hours prior to performing a calibration will
provide better results.
20
7. Maintenance
ALWAYS LOCKOUT/TAGOUT THE PUMP MOTOR BEFORE PERFORMING MAINTENANCE
OF ANY KIND.
WHERE HAZARDOUS PROCESS MATERIALS ARE INVOLVED, RENDER THE PUMP SAFE TO
PERSONNEL AND THE ENVIRONMENT BY CLEANING AND CHEMICALLY NEUTRALIZING AS
APPROPRIATE. WEAR ALL REQUIRED PROTECTIVE CLOTHING AND USE PROTECTIVE
EQUIPMENT.
Accurate records from the early stages of pump operation will indicate the type and levels of
required maintenance. A preventative maintenance program based on such records will minimize
operational problems. It is not possible to forecast the lives of wetted parts such as diaphragms
and check valves. Since corrosion rates and operational conditions affect functional material life,
each metering pump must be considered according to its particular service conditions.
PulsaPro Series KOPkits contain all replacement parts normally used in a preventative
maintenance program. It is recommended that KOPkits and PULSAlube oil be kept available at
all times.
Each PulsaPro Series pump is provided with an individual specification data sheet included
with the documentation package. The data sheet contains important information relating to the
application along with pump serial number, pump specifications (i.e., materials, piston size,
stroking rate, etc.).
21
7.1 Wet End Removal, Inspection, and Reinstallation
IF THE DIAPHRAGM HAS FAILED, PROCESS FLUID MAY HAVE CONTAMINATED THE
PUMP OIL. HANDLE WITH APPROPRIATE CARE, CLEAN AND REPLACE OIL IF
REQUIRED.
DUE TO THE SIZE AND WEIGHT OF WET END COMPONENTS, CARE MUST BE USED TO
SELECT THE PROPER TOOLS AND LIFTING EQUIPMENT FOR HEAVY LOADS.
Figure 12
PulsaPro Series diaphragms do not have a specific cycle life. However, the accumulation of
foreign material or the entrapment of sharp particles between the diaphragm and dish cavity can
eventually cause failure. Failure can also occur as a result of hydraulic system malfunction or
chemical attack. Periodic diaphragm inspection and replacement is recommended.
TAKE ALL PRECAUTIONS TO PREVENT ENVIRONMENTAL AND PERSONNEL EXPOSURE
TO HAZARDOUS MATERIALS.
22
Diaphragm Replacement procedure
1. Disconnect the power source to the drive motor (e.g., lockout/tagout the motor disconnect).
2. Relieve all pressure from the piping system.
3. Close the suction and discharge shutoff valves (refer to Figure 8A).
4. Disconnect piping to the reagent head and drain any process liquid, following material safety
precautions from the process liquid manufacturer.
5. Place a pan underneath the pump head to catch any oil leakage from the pump.
6. If the oil is known to be contaminated by process fluid (e.g., the diaphragm has ruptured, the oil
is discolored, etc.) drain the oil by opening the oil drain valve below the base at the back of the
pump.
7. Remove the suction and discharge check valves as described in Section 7.3.1. Pour out any
liquids retained by the check valves into a suitable container, continuing to follow safety
precautions as appropriate.
8. Attach lifting means (e.g., straps, rigging and hoist) to support the reagent head during removal.
9. Remove the 10 nuts that secure the reagent head to the pump head.
OIL MAY LEAK OUT BETWEEN THE PUMP HEAD AND REAGENT HEAD AS THE REAGENT
HEAD BOLTS ARE LOOSENED.
10. Carefully slide the regent head straight off towards the end of the studs, please use caution not
to damage the threads.
11. Rinse or clean the reagent head with an appropriate material/method.
12. Remove and inspect the diaphragm. It may have taken a permanent convex or concave set as a
result of normal flexure and conformance to the dish plate. This condition is normal and is not
cause for replacement.
13. Ensure that the critical sealing areas of the diaphragm, reagent head, and pump head are clean
and free of debris.
14. When reinstalling a used diaphragm it is important to maintain the previous orientation relative
to the reagent head and pump head hole pattern.
15. Place the diaphragm into the circular groove in the reagent head press firmly around the outer
edge. The groove will hold the diaphragm in place until you install the reagent head to the
pump head.
16. Carefully move the reagent head into place over the studs.
17. Install the reagent head hold-down nuts finger tight (just in contact with the reagent head front
face).
18. Torque the nuts in an alternating pattern as defined in Appendix III. Initially torque the nuts to
one half the recommended value. Repeat the pattern, tightening the nuts to the specified value.
19. Re-install the suction and discharge check valves.
20. Re-install the suction and discharge piping.
21. Re-prime the pump following the procedure outlined in the next section.
23
7.2 Re-Priming the Pump Head
The PulsaPro must maintain hydraulic prime to operate properly. While its Hydraulic System includes
several components to protect its prime – the HPV, HBV and PTP – they will not automatically restore
hydraulic prime if the oil is drained from the hydraulic chamber (the space between the piston and the
diaphragm). This would commonly occur when the diaphragm is replaced for example. This procedure
describes how to efficiently re-prime the Pump Head.
Re-Priming the Pump Head is not required when performing a normal oil change. Typically
the Pump Head hydraulic chamber will retain its prime while you drain the oil using the
drain valve in the Gear Box.
This procedure may be helpful in cases where the system has experienced a severe upset (for
example, when a valve in the suction line is shut off for more than 30 minutes).
RESERVOIR
HYDRAULIC CHAMBER
DIAGNOSTIC WINDOW
RESERVOIR OIL LEVEL
Figure 13
24
7.2.1 Re-Filling the Hydraulic System
Use the following procedure to refill the Hydraulic System after Diaphragm/Piston service or
extreme system upset conditions:
1. Disconnect the power source to the drive motor (e.g., lockout/tagout the motor disconnect).
2. Check the Pump Head Oil Level (refer to Section 6.1.3 Oil Changes). Restore levels in the
Pump Head Reservoir if necessary.
3. Remove the PTP valve from the Pump Head carefully to access the Hydraulic Chamber. There is
an o-ring and copper gasket that need to be properly handled and protected from damage.
OIL MAY LEAK OUT FROM AROUND THE PTP VALVE. TAKE APPROPRIATE MEASURES
TO CAPTURE AND CONTAIN IT.
PTP
Cross Drilled Hole
O-Ring
Figure 14
The ball check valve incorporates a ball, guide, and seat. Flow in the unchecked direction
lifts the ball off the seat, allowing liquid to pass through the guide. Reverse flow forces the
ball down, sealing it against the sharp edge of the seat. The guide permits the ball to rotate
but restricts vertical and lateral movement in order to minimize “slip” or reverse flow. Ball
rotation prolongs life by distributing wear over the entire surface of the ball. Since ball return
is by gravity, the valve must be in the vertical position in order to function properly. Parts are
sealed by o-rings.
The disk valve functions in the same manner as the ball valve, except that the ball is replaced
by a spring-loaded guided disk. The seat may contain a captured o-ring to facilitate sealing.
26
7.3.1 Check Valve Removal
TAKE ALL PRECAUTIONS TO PREVENT ENVIRONMENTAL AND PERSONNEL EXPOSURE
TO HAZARDOUS MATERIALS.
1. Disconnect the power source to the drive motor (e.g., lockout/tagout the motor disconnect).
2. Relieve all pressure from the piping system.
3. Close the suction and discharge shutoff valves (refer to Figure 8A).
4. Loosen the suction valve tie-bar bolts and spring the suction piping slightly to drain any liquid
from the reagent head cavity. If the piping is closely connected it may be necessary to
disconnect a union or flange.
5. Remove the suction check valve assembly, holding it together as a unit.
6. Loosen the tie bar bolts on the discharge valve and spring the piping slightly to drain any liquid.
7. Remove the discharge check valve assembly, holding it together as a unit.
7.3.2 Ball Valve – Inspection and Repair
1. Disassemble both the suction and discharge check valves.
The ball seats should have sharp edges or a small chamfer and be free from dents or nicks.
2. Examine components for wear by holding the ball firmly against its mating seat in front of a
bright light to inspect for fit.
Observation of light between the ball and seat is cause for replacement of either or both
components.
3. Reassemble both valves using new parts as required. The o-rings should always be replaced.
7.3.3 Disk Valve – Inspection and Repair
1. Disassemble valves and inspect components for wear.
The seats and lower disk surfaces contacting the seats should remain flat and smooth.
Although it is normal for the o-ring in the seat to be flattened after significant use,
replacement is recommended as a part of valve maintenance.
2. The seat o-ring is captured by an internal lip in its groove in the seat. Removal requires the
following destructive procedure:
a) Position a small blade type screwdriver against the outer edge of the o-ring at an angle of
approximately 45 degrees.
b) Taking care not to damage the sides of the seat, drive the screwdriver into the o-ring.
c) Using the screwdriver, pry one section of the o-ring out of the groove.
d) Grip the O-Ring with pliers, and remove it from the seat.
3. To install the replacement seat o-ring; place it on the seat above the groove.
4. Position a flat metal object over the o-ring
5. Apply uniform light pressure using a hand arbor press.
The slight movement that accompanies seating can be easily felt through the press
handle.
DO NOT TRY TO INSTALL THE RING BY HAMMERING, AS THE SEATING WILL NOT BE
UNIFORM. THE RING MAY BE DAMAGED AND THE PUMP PERFORMANCE MAY BE
IMPAIRED.
6. Reassemble both valves using new parts as required. Sealing O-Rings should always be
replaced.
27
7.3.4 Check Valve Reinstallation
1. Reinstall both valve assemblies, taking care to ensure that they are correctly oriented with balls
or disks above seats. Refer to Figure 14.
2. Tighten the tie bar bolts evenly, making sure the valve assemblies and tie bar are assembled
squarely. Refer to Appendix III for torque values.
For best results, always loosen the unions or flanges on either side of the system piping prior
to re-tightening the check valve assemblies. Retighten the unions or flanges after the check
valves are securely tightened into position.
28
7.4 Hydraulic Performance Valve (HPV)
During normal pump operation hydraulic fluid is continually discharged through the
automatic bleed valve and may also be lost past the piston seals. This causes the diaphragm
to be drawn further back on each successive suction stroke until it actuates the HPV. Once
the valve is actuated, oil is allowed to flow into the hydraulic system until the piston reaches
the end of the suction stroke. As the piston starts forward a Hydraulic Makeup Valve (HMV)
prevents oil from flowing back through the HPV, thereby allowing the valve to close as the
diaphragm moves forward. Through this process the diaphragm is continually maintained in
the proper operating position relative to the pump head dish plate. Since the HPV is
unaffected by the vacuum level in the pump head, oil cannot be inadvertently brought into the
hydraulic system which would result in over-extension and damage to the diaphragm. This
feature provides pump protection should the suction line become intermittently restricted or
closed.
PulsaPro 900 High Performance Valves (HPV) and Hydraulic Makeup Valves (HMV)
are factory preset and require no maintenance provided the oil remains clean. Should the
HPV require removal for cleaning or replacement follow the below procedure.
Figure 15
29
7.4.1 HPV Removal and Replacement
1. Disconnect the power source to the drive motor (e.g., lockout/tagout the motor disconnect).
2. Relieve all pressure from the piping system.
3. Drain the oil from the eccentric box / pump head by opening the drain valve.
4. Remove the reagent head and diaphragm using the procedure outlined in Section 7.1.
5. The dish plate is held in the pump head by two sealing o-rings. Install screws into the two M4
x 0.7 threaded jacking locations to remove the HBV / Dish plate assembly properly. Tighten
them into the dish plate to jack it out of the pump head. Take care to prevent dropping the
dish plate on final removal.
Jacking O-Rings
Locations
6. If cleaning of the valve is required, use a solvent compatible with Nitrile rubber and blow air
through the valve to remove all contaminants.
7. Inspect the O-Rings on the body of the valve for nicks or other damage and replace if
required.
8. Lubricate the O-Rings with PULSAlube Universal or Ultra and carefully insert the HPV
into the dish side bore of the pump head.
9. Rotate the valve and dish insert into the pump head until the hole on the back side of the outer
edge aligns with the alignment pin. Seat dish in counter bore.
ALIGNMENT PIN
30
Figure 16
10. Reinstall the diaphragm and the reagent head using the procedure outlined in Section 7.1.
11. Close the Gearbox / Pump Head drain valve and fill with PULSAlube Universal or Ultra
hydraulic oil.
12. Re-prime the pump head.
ADJUST
HBV
HERE
Figure 17
The HBV is located on the left side of the pump head as you face the reagent head. Discharge
from this valve is visible through a large diameter tube located behind the diagnostic port that
faces the same side of the pump (refer to figure 17). Whenever discharge is visible, it indicates
the pressure in the pump discharge piping exceeds the HBV setting. After confirming the
discharge pressure is within the rated pressure of the pump it may be necessary to adjust the
HBV setting.
Pump damage may occur during a system upset if the hydraulic bypass pressure is set higher
than 10% over the design pressure of the pump (refer to the nameplate rating). Conversely, if
31
the setting is too low the valve will operate on each discharge stroke. This results in decreased
pumping capacity and will eventually affect the efficiency of the valve.
To check the hydraulic bypass pressure setting, install a gauge and a back pressure valve in the
pump discharge line. The gauge must be between the pump and the back pressure valve (for
convenience, locate the two as close to the pump as possible). With the pump operating at
maximum stroke length, gradually increase the discharge pressure and observe when the HBV
starts to operate through the diagnostic window. The cracking pressure of the valve must be at
least as high as the maximum pressure of the system but no more than 10% over the pump’s
rated pressure. After adjustment tighten the lock nut and reinstall the metal cover.
Periodic inspection of the valve seat is recommended. If it becomes worn or damaged leakage
will occur regardless of how tightly the valve is adjusted.
OBSERVE
PTP FLOW
HERE
Figure 18
The PTP (Push to Purge) Valve is a gravity-operated disk check valve that automatically
removes gases from the hydraulic system. On each discharge stroke of the pump, pressure
generated by the piston lifts the disk off a lower seat. If accumulated gasses are present the
gasses flow around the disk and are vented to the reservoir. If there are no gasses present
then oil forces the disk to shut off against an upper seat – limiting the amount of fluid that
escapes. On each suction stroke, the disk returns (by gravity) to the lower seat to prevent
reentry of gas into the system. By this mechanism, under normal operation, a small amount
of oil is displaced with each discharge stroke. This oil is returned by gravity to the reservoir
where it is recycled. The PTP removes minute accumulations of gas long before they are
visible or detrimental to pump operation.
The PTP includes a spring-loaded button at the top of the valve that is used to accelerate the
purging of accumulated gasses in the hydraulics. Holding the button down momentarily
opens the disk valve so that large amounts of gas and hydraulic fluid can be instantly purged.
When the button is released, the valve returns to normal automatic operation. PTP operation
can be monitored by observing oil flow through the small tube behind the diagnostic window.
32
7.5.2 PTP Removal, Cleaning, and Reinstallation
1. Disconnect the power source to the drive motor (e.g., lockout/tagout the motor disconnect).
2. Relieve all pressure from the piping system.
3. Slowly unscrew the valve to gradually relieve any residual hydraulic system pressure.
OIL MAY LEAK OUT FROM AROUND THE PTP VALVE. TAKE APPROPRIATE
MEASURES TO CAPTURE AND CONTAIN IT.
This valve is not repairable and must be replaced if it continues to malfunction after
cleaning.
PTP BUTTON
O-Ring
Copper Gasket
Figure 18a
33
7.5.3 Piston Seal
7.5.3.1 General Description
The piston assembly has 2 different design structures as shown in Figure 19. With proper
maintenance, piston seals should give you years of service.
Figure 19
Figure 20
34
7.5.4 Piston Removal
Piston Removal Procedure:
1. Remove reagent head, and dish plate using the procedure defined in Section 7.4.1, HPV
Removal.
2. Remove the nut from the end of the cross head shaft assembly.
3. Set the stroke adjustment setting to 100%.
4. Rotate the Motor by hand (confirm lockout/tag out) until the piston achieves its full forward
position.
5. Continue Motor rotation until the cross head shaft is pulled from the hole in the center of the
piston assembly.
6. Hook the piston assembly through hole in center and pull the piston straight out of the piston
bore by exerting even tension.
Figure 21
35
1. Apply PULSAlube Universal or Ultra hydraulic oil to all the piston assembly components. No
matter which piston size you have.
1.1 Slide the smaller of the 2 o-rings over the threaded end of the cross head.
1.2 Install the spacer onto the threaded end of the cross head.
1.3 Install the piston cup with the outer lip facing away from the cross head.
1.4 Install the larger o-ring into the groove on the outside diameter of the Expander.
1.5 Install the expander onto threaded end of the cross head.
1.6 Assure all components slide back onto the threaded end of the cross head until they
bottom out (refer to Figure 21).
1.7 Please confirm that the expander with the o-ring on the outside diameter lies flat
inside the piston cup when fully pushed rearward. Proceed to Step 2 of this section.
1.1 Slide the smaller of the 2 o-rings over the threaded end of the cross head.
1.2 Install the seal retainer onto the threaded end of the cross head.
1.3 Install the seal onto the seal retainer. Make sure the seal is seated properly all the way
around the retainer.
1.4 Install the unitized piston.
1.5 Assure all components slide back onto the threaded end of the cross head until they
bottom out (refer to Figure 21).
1.6 Please double check the seal to assure it is seated properly to the seal retainer. Proceed
to Step 2 of this section.
2. Install the flat washer and lock washer onto the end of the threaded shaft.
3. Apply Loctite® 242 (™ Henkel Corporation) removable anaerobic thread locking compound to
the threads on the threaded end of the Cross head.
4. Hand tighten the Piston retaining nut onto the threaded end of the cross head.
5. Torque the nut to 140 foot-pounds. This will draw the piston onto the end of the cross head and
cause it to bottom out on the shoulder.
6. Replace the reagent head and diaphragm as described in Section 7.1, Wet End Removal,
Inspection and Reinstallation.
7. Fill the pump head with PULSAlube Universal or Ultra and prime the pump head as
described in Section 6 – Equipment Startup.
36
7.6 Oil Seals
7.6.1 General Description
The PulsaPro 900 gear box has seven primary oil seals. Six of these are static o-ring
seals. Only one (the Worm Oil Seal) is dynamic and should be serviced at regular intervals.
Pump
Worm Oil Head Seal
Seal
Rear Cover
Seal
Worm
Bearing
Cover
Sub-Cover
Seal
Eccentric
Cover Seal
Main Cover
Seal
Figure 23
37
7.6.2 Motor Adaptor Oil Seal Removal and Replacement
7.6.2.1 Motor Adaptor Removal and Worm Oil Seal Replacement
1. Disconnect the power source to the drive motor (e.g., lockout/tagout the motor disconnect).
2. Attach required lifting device to the motor. Do not put any tension on the pump motor at this
time.
3. Remove the four Motor Attachment Bolts from the motor (refer to Figure 24).
4. Open the Access Panel by removing the three Access Panel Screws.
Figure 24
5. Remove the Motor and Upper Coupling assembly by lifting straight up.
6. Remove the four motor adapter bolts and lift the motor adapter from the gearbox.
7. Rotate the Lower Coupling Assembly by hand until the Coupling Setscrew is visible.
8. Loosen the Lower Coupling Setscrew.
9. Remove the lower coupling and coupling spider.
Figure 25
38
Figure 26
10. Remove the four seal retainer bolts and seal retainer.
11. Remove the input shaft oil seal from the input shaft adjustment nut.
12. Lubricate the replacement input shaft seal with silicone grease or PULSAlube Universal or
Ultra.
13. Slide the input shaft adjustment nut onto the input shaft and begin tightening. The input shaft
adjustment nut should have about .002in (0.05mm) max end play.
14. Install the input shaft oil seal by pressing it into position. Be careful not to cut the seal on the
key way of the shaft.
15. Install the Motor Adaptor over the gearbox input shaft and then bolt in place.
16. Slip the Lower Coupling and Spider over the input shaft.
17. Position the coupling half flush to the end of the input shaft.
18. Tighten the coupling setscrew.
19. Lower the motor / Upper Coupling into position. As you are positioning the motor, it may be
necessary to rotate the Lower Coupling / Spider assembly to facilitate proper alignment.
20. Once the coupling is aligned, lower the motor assembly until full contact has been made with
the lower coupling.
21. Insert and tighten the motor mounting bolts that were removed in Step 3.
22. Restore power to the PulsaPro 900 pump assembly.
39
7.7 Stroke Control Assembly
7.7.1 Stroke Control Assembly Maintenance
The manual stroke adjust housing has an upper bearing and a long threaded shaft that needs
to be greased (Refer to Figure 27).
1. Disconnect the power source to the drive motor (e.g., lockout/tagout the motor
disconnect).
2. To access the grease fitting remove Qty 6 lens cover bolts.
3. Remove the protective lens cover.
4. Adjust the stroke setting from 100 % down to approximately 65%. The grease fitting
should be visible in the slot that the stroke setting indicator rides in.
5. Use a standard grease gun to inject Heavy Duty Grease (e.g., NLGI #2 Lithium
Complex Grease) until resistance is felt.
Figure 27
40
7.8 Motor Removal and Reinstallation
1. Disconnect the power source to the drive motor (e.g., lockout/tagout the motor disconnect).
2. Disconnect the motor wiring from the motor.
3. Attach required lifting device to the motor. Do not put any tension on the pump motor at this
time.
4. Remove the four Motor Attachment Bolts from the motor (refer to Figure 24). Some European
motors will have eight bolts
5. Open the access panel by removing the three access panel screws to expose the coupling.
The coupling is an interlocking jaw design and uses an elastomeric spider between the two
coupling halves. The upper half of the coupling remains on the motor shaft and the lower
half stays on the worm gear shaft.
41
8. Replacement Parts
8.1 PulsaPro Series KOPkit Program
PulsaPro Series KOPkits contain all replacement parts normally used in a preventative
maintenance program.
KOPkits can also be selected from the technical data sheet shipped with the pump or by a
Pulsafeeder representative.
PulsaPro Series part numbers begin either with the letters “NP”, “RS” or the letter “W”,
e.g., NP170001-TNR or W210221-001.
42
9. PULSAlarm Leak Detection Pump Head Assembly
The PULSAlarm leak detection pump head assembly consists of pump head or reagent head,
leak detection diaphragm, fill port, and pressure switch and gauge. The reagent head,
diaphragm, suction and discharge check valves are the only parts of the pump to contact the
process liquid -consequently, maintenance is critical to pump performance.
Figure 24
43
9.2 Leak Detection – Setup for Pressure
Pumps incorporating pressure leak detection are shipped from the factory with the system fully
set up to work at full pump pressure. No further setup is required. The standard factory barrier
fluid is Silicone LD, if any other customer-specified media is used it must be compatible with
construction materials. The system will require proper setup after maintenance or repairs see
section 9.3 on the following page for the proper procedure.
Figure 25
44
9.3 Pressure System Set-up and Priming
If the pressurized leak detection system is opened to the atmosphere during maintenance
or inspection, the system must be re-primed properly to avoid diaphragm damage and
ensure proper leak detection operation and system performance.
1. Complete re-assembly of the diaphragm, reagent head, and external components. Ensure
that reagent head and tie-bar bolts are tightened according to the appropriate torque
specifications (consult Appendix III)
2. Remove the pressure gauge from the housing body and replace with the straight tubing
connection supplied with the pump. Connect a vacuum supply (hand vacuum pump) to the
tube fitting.
If the system was previously sealed, you may need to remove the plug and re-install the
hose fittings at the fill port. There should be a container in the vacuum line to trap excess
barrier fluid. An inexpensive automotive brake bleeding kit is appropriate for this
purpose.
3. Connect the fill tube to the fill valve tube connection. Any short length of the appropriate
sized tubing may be used for this purpose.
4. Open the fill valve.
5. Place the fill tube into a container of the barrier fluid being used.
6. Apply vacuum, the fluid should rise into the fill tube and enter the system.
7. Observe the fluid at the exit (vacuum pump) side. When clear, air free fluid is observed,
close the fill valve, while maintaining the vacuum on the system to begin the process of
drawing out excess fluid.
If you are re-using a previously installed diaphragm, it will take time for the Silicone LD
fluid to migrate through the system, be patient!
8. Release the vacuum, and remove both the fill tube and the vacuum pump from the fittings.
9. Empty the fill tube of fluid, and place it on the fitting near the switch, extending upwards, and
open to the atmosphere.
10. Ensure that the eccentric box of the pump has been filled to the appropriate level with the
correct hydraulic fluid.
11. Adjust the pump to the zero stroke (0%) position.
45
12. If the pump is not already hydraulically primed, remove the PTP valve from the top of the
pump head. Using a plastic funnel or similar, slowly pour hydraulic fluid into the pump head
cavity until full. The end of the funnel should fit into the small diameter hole at the bottom of
the PTP socket – not the larger threaded diameter. The threaded diameter includes a side
drain passage that will prevent oil from entering the pump head if used. Alternatively apply a
Drain
Passage Funnel
should
enter here
vacuum to the bottom hole of the PTP socket to draw oil from the makeup valve.
13. Inspect the PTP valve to ensure the sealing o-ring and copper gasket are still in position, and
re-install the valve.
14. In order to fully balance and evacuate the leak detection system, the pump must now run at
normal discharge pressure for a period of one hour. This ensures that excess barrier fluid is
fully evacuated from the system.
15. Supply either process fluid, or test fluid (i.e. water) to the suction of the pump and ensure that
the discharge system is configured for safe operation. The pump can be started with minimal
discharge pressure and then slowly brought up to full pressure, if the system allows for this.
16. Apply power and start the pump.
17. Adjust the pump slowly to full (100%) stroke.
18. Hold down the PTP valve momentarily and observe the smaller tube under the diagnostic
cover. If no fluid is coming from this port after 5 minutes, stop the pump and return to step
11. If fluid is present, continue to step 19.
19. Slowly increase the discharge pressure to full operating pressure, and continue to run the
pump for a period of one hour.
20. During this time, excess barrier fluid will be displaced from the system into the short length
of tubing attached to the exit port, balancing the system for proper operation. A small pen
mark on the tube can assist in observing this process visually.
21. After the one-hour startup period, remove the tubing and connection from the housing body
and reinstall the pressure gage. Remove the fitting from the fill port and replace with the
supplied pipe plug.
22. Reconnect the alarm switch to the external system if necessary.
23. The pump and pressure leak-detection system are now properly prepared and ready for
normal service. During normal operation, the gauge should roughly indicate 0 (zero)
pressure.
Under certain circumstances, the system may not completely evacuate excess barrier fluid
during the procedure as outlined above. In these cases, after several days run time, a
small amount of pressure may build in the system. If this occurs, simply loosen the
pressure gauge from the switch housing and relieve a small amount of barrier fluid,
returning the system to a zero-pressure state.
Once this startup procedure is completed, the pressure leak detection system should
require no further maintenance.
46
9.4 PULSAlarm Leak Detection Diaphragm Maintenance
Figure 27
47
9.4.1 Leak Detection Diaphragm Removal
9.4.2 Inspection
Remove and inspect the diaphragm assembly. It may have taken a permanent
convex/concave set as a result of normal flexure and conformance to the dish-plate. This
condition is normal and is not cause for replacement. The diaphragm must be replaced if it is
deformed, dimpled, or obviously damaged.
If the diaphragms have been removed from the spacer ring, the entire assembly should be
replaced to ensure proper sealing of its components.
48
10. Troubleshooting Chart
Difficulty Probable Cause Remedy
Pump does not 1. Coupling disconnected Connect coupling
start 2. Faulty power source Check power source
3. Blown fuse, circuit breaker Replace - eliminate overload
4. Broken wire Locate and repair
5. Wired improperly Check wiring diagram
6. Closed line valves Open valves
No delivery 1. Motor not running Check power source. Check wiring diagram.
2. Supply tank empty Fill tank
3. Lines clogged Clean and flush
4. Closed line valves Open valves
5. Check valves held open with Clean - inspect
solids
6. Vapor lock, cavitation Increase suction pressure
7. Prime lost Re-prime, check for leak
8. Strainer clogged Remove and clean. Replace screen if necessary
9. Hydraulic system under-primed Refer to Re-priming the Pump
Low delivery 1. Motor speed too low Check voltages, frequency, wiring, and Terminal
connections. Check nameplate vs. Specifications.
2. Check valves worn or dirty Clean, replace if damaged
3. Hydraulic bypass valve operating Refer to Hydraulic Bypass Valve
each stroke
4. Calibration system error Evaluate and correct
5. Product viscosity too high Lower viscosity by increasing product temperature.
Increase pump and/or piping size
6. Product cavitating Increase suction pressure. Reduce product temperature
7. Piston seal worn or damaged by Inspect and replace if necessary, refer to Piston Seal.
contamination
8. Air entrained in Oil (foaming Refer to Re-priming the Pump
from PTP diagnostic tube)
Delivery gradually 1. Check valve leakage Clean, replace if damaged
drops 2. Leak in suction line Locate and correct
3. Strainer fouled Clean or replace screen
4. Product change Check viscosity
5. Bypass leakage Correct for bypass valve leakage
6. Piston seal worn or damaged by Inspect and replace if necessary refer to Piston Seal
contamination
7. Supply tank vent plugged Unplug vent
8. Air entrained in Oil (foaming Refer to Re-priming the Pump
from PTP diagnostic tube)
Delivery erratic 1. Leak in suction line Locate and correct
2. Product cavitating Increase suction pressure
3. Entrained air or gas in product Consult factory for suggested venting
4. Motor speed erratic Check voltage and frequency
5. Fouled check valves Clean, replace if necessary
6. Air entrained in Oil (foaming Refer to Re-priming the Pump
from PTP diagnostic tube)
Delivery higher 1. Suction pressure higher than Install back pressure valve or consult factory for piping
than rated discharge pressure recommendations
2. Discharge piping too small Increase pipe size - install pulsation dampener in
discharge line
3. Back pressure valve set too low Increase setting
4. Back pressure valve leaks Repair, clean, or replace
49
Difficulty Probable Cause Remedy
Pump loses 1. Diaphragm ruptured Replace
hydraulic oil 2. Leaky seal Replace
3. Cover gasket leaks Replace or retighten
4. Eccentric box overfilled Remove excess oil
Motor overheats 1. Pump overloaded Check operating conditions against pump design
requirements
2. High or low voltage Check power source
3. Loose wire Trace and correct
Diaphragm 1. Diaphragm extruded into pump Reduce discharge pressure to pump design limits.
Damage head holes Relieve discharge pressure before stopping pump.
Verify PTP bleeder is bypassing oil. Increase dynamic
suction pressure to at least 5 psia. Replace or clean
hydraulic performance valve. Replace worn piston
seals.
50
Appendix I – Piping Calculations
Suction Head Requirements
All reciprocating metering pumps require a net positive suction head (NPSHR). Refer to Table
1 for the (NPSHR) required for PulsaPro Series pump models. The NPSHR is defined as the
pressure required above the absolute vapor pressure of the process fluid at the pumping
temperature. This pressure is required at the suction port of the pump throughout the entire
pump stroking cycle in order to prevent cavitation of the process fluid within the reagent head.
The NPSHR is one of the requirements necessary to assure metering accuracy.
NPSHR
English (psi) 3
Metric (bar) 0.35
Table 1. NPSHR values
The net positive suction head available (NPSHA) must be greater than the NPSHR. The NPSHA
of any given system is calculated as follows for comparison to the NPSHR as shown in Table 1.
The variables used in Equations 1 through 5 must be in the units shown in Table 2 for the
constants listed below to be used correctly.
51
Units Set
Variable
English Metric
Table 2. Unit sets and constant values for use in Equations 1 through 5.
If piping sizes vary throughout the suction line, different additive values may be used for
the pressure losses attributed to the liquid’s acceleration and deceleration.
Use the last term of Equation 1 or 2 as many times as needed in the equation to adjust for
different lengths/pipe diameters in the suction line. (Everything but the pipe length and
diameter will stay the same in the equation.)
All reciprocating metering pumps also require that a minimum absolute pressure,
minimum suction head (MSH), be maintained at the pump inlet throughout the pumping
cycle to ensure a stable hydraulic system and proper pump operation.
MSH
English, (psia) 5.0
Metric, (bar(a)) 0.35
Table 3. Minimum values for the sum of NPSHA and vapor pressure. (MSH)
The sum of the NPSHA and the vapor pressure (PV) must be greater than the values shown
in Table 3.
52
System Back Pressure
The system back pressure must exceed the suction pressure by at least 25 psi (1.7 bar) in order
to prevent flow through; however it must not exceed the rated discharge pressure of the pump.
Flow through can be defined as the process liquid flowing from a higher pressure to a lower
pressure (downhill pumping), which attributes to pump failure and undesired flow at pump
shutdown.
If the system back pressure is not at least 25 psi (1.7 bar) greater than the suction pressure, a
back pressure valve must be installed in the discharge piping. To calculate the system’s total
back pressure use Equation 3 or 4 below.
Nomenclature
NPSHR = Net positive suction head required, [psi, bar]
NPSHA = Net positive suction head available, [psi, bar]
PA = Pressure at the surface of the liquid being pumped (atmospheric or supply tank
blanket pressure) [psi(a), bar(a)]
PH = Head pressure above (+) or below (-) the pump centerline, [psi, bar,] (convert
from ft or m)
PV = Absolute vapor pressure at pumping temperature of the process liquid at pump
inlet, [psi(a), bar(a)]
LS = Length of suction piping (actual, not equivalent), [ft, m]
R = Pump stroking rate, strokes/min [spm]
G = Specific gravity of process liquid, [no units]
Q = Pump average flow rate, [gph, lph]
d = Internal pipe diameter, [inches, mm]
C1 ,C2 ,C3 = Numeric constants used in Equations 1- 5 [no units]
µ = Viscosity of process liquid at pumping temperature, centipoise [cp]
LD = Length of discharge piping (actual, not equivalent), [ft, m]
PP = System discharge pressure, [psi(g), bar(g)]
PT = Peak pump discharge pressure at the discharge port, [psi(g), bar(g)]
VP = Peak liquid velocity generated by the pump, (suction or discharge) [ft/s, m/s]
53
Appendix II – Oil Specifications
54
Appendix III – Bolt Torque Recommendations/Nozzle
Loads
Reagent Head and Tie-Bar
REAGENT
RH PART PISTON SIZE TORQUE
HEAD DESCRIPTION
NUMBER (in) FT-LBS / N-m
SIZE
REAGENT HEAD, NUT, M30-
3.5 310 / 420
12.5 NP160085-316 5.50 TIE BAR, NUT, M24-3.0 95 / 129
REAGENT HEAD, NUT, M30-
3.5 410 / 555
10.5 NP160084-316 4.00 TIE BAR, NUT, M24-3.0 100 / 135
REAGENT HEAD, NUT, M30-
3.5 970 / 1314
8.5 NP160083-316 2.00, 2.50, 3.00 TIE BAR, NUT, M30-3.5 315 / 427
REAGENT HEAD, NUT, M24-
3.0 515 / 697
6.0 NP160082-316 1.75 TIE BAR, NUT, M30-3.5 405 / 548
When torquing the bolts, make sure you start with bolts equally hand tight. Then torque to
one half the specified rating following the bolt patterns below. Once you have completed the
first pass, then torque to the final rating.
55
Nozzle Loads
56
Appendix IV Dimensional Drawings
57
58
59
60
61
Appendix V EC Declaration of Conformance
62
An ISO 9001 and 14001 Certified Company
P u l safe ede r , In c .
2 883 B r ig ht on-H en r iett a T ow n Lin e Ro ad
Ro ch est er, N Y 14 623
Ema il: pu ls a@ id exco rp .co m
T e le ph one: ++1 (58 5) 2 92- 800 0
F ax: ++ 1 (5 85) 424- 56 19
P u l safe ede r .c o m B u l l et in N o : P u l sa Pr o90 0- IO M-2 00 9 R e v. G