The hotwell at the bottom of the condenser collects condensate, where the condensate pump takes suction. The cooling water flow and temperature through the condenser control the condensate temperature and saturation pressure (vacuum) in the condenser. To maintain proper vacuum, the hotwell level should be kept at a normal level of 0mm. If the level falls, a make-up valve opens to add demineralized water. Maintaining the hotwell level around 200mm ensures adequate vacuum for the turbine while preventing vacuum deterioration.

Uploaded by

marpel
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
106 views

Lesson 3.7 Describe How To Keep The Hot Well Level of Condenser

The hotwell at the bottom of the condenser collects condensate, where the condensate pump takes suction. The cooling water flow and temperature through the condenser control the condensate temperature and saturation pressure (vacuum) in the condenser. To maintain proper vacuum, the hotwell level should be kept at a normal level of 0mm. If the level falls, a make-up valve opens to add demineralized water. Maintaining the hotwell level around 200mm ensures adequate vacuum for the turbine while preventing vacuum deterioration.

Uploaded by

marpel
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Lesson 3.

7 Describe how to keep the hot well level of condenser

The bottom area of the condenser is the hotwell. This is where the condensate
collects and the condensate pump takes its suction. ... The temperature and flow
rate of the cooling water through the condenser controls the temperature of the
condensate. This in turn controls the saturation pressure (vacuum) of
the condenser.
Set Points Of Levels In Condenser Hot Well
1. Generally we try to maintain hot well level at 0 MM or normal level.
2. If hot well level falls below 0 mm, normal make up valve will open and allow
DM (demineralize) water to condenser in order to maintain normal level. At
Low level this normal make up valve will be fully opened. The hot well level is
to be maintained to normal level (200mm). This is why because, if the water
level in the hot well goes below the desired level, the vacuum level increases
so that the low pressure turbine blades gets sucked along with the
steam by the vacuum pressure and if the water level in the condenser raises
above the desired level, then deterioration of vacuum takes place.