Dear Mamoun,
Thanks & Best Regards,
Ahmed Ibrahim _ Project Coordinator
BAJRAWIA Factory for oil & gas Equip.
Al‐Tayif, Badir Street – Block No. 22, Building No. 556‐ Khartoum ‐ Sudan
E mail: [email protected] – Mob: +249 901237664 – Web: www.bajrawiafab.com
From: Focus Engineering [mailto:[email protected]]
Sent: Tuesday, August 18, 2020 4:03 PM
To: Ahmed Ibrahim Abdelmageed <[email protected]>
Subject: Fw: AW: EXT: Bajrawia Problem
1
E-mail: [email protected], [email protected]
http://www.focus.sd
Add to Anti-Banner
Add to Anti-Banner
Dear Mohammed,
The problem is that the customer is using the wrong combination of wire and flux and hence we suggest to communicate
directly with the client on a technical level by our welding experts.
In the photos sent earlier we have seen that Bajrawia is using an EM 12 K wire and therefore recommended the flux
based on this information.
We have offered the UV C 401 flux to the customer because they are using an EM 12 K wire and with this wire the best
flux to use is the UV C401 flux. This wire and flux will meet impact requirements up to -40 °C.
If the client has a requirement of F7A8 then they should use an EH 12 K wire and not an EM 12 K wire. This wire and flux
will meet impact requirements up to -62 °C . In this case we recommend to use our Union S3 Si with UV 418 TT flux.
Please try to find out what the impact requirements of Bajrawia are and we suggest to start a technical dialogue with them
on this aspect.
Best regards
2
________________________________
Andreas Iburg
Elsässer Str. 10
www.voestalpine.com/welding
Sitz der Gesellschaft/Registered Office: HRB 9242 at the District Court Hamm
This email message and any attachments are for the sole use of the intended recipient(s) and contain confidential and/or privileged information. Any
unauthorized review, use, disclosure or distribution is prohibited. If you are not the intended recipient, please contact the sender by reply email and
destroy all copies of the original message and any attachments.
3
Von: Focus Engineering <[email protected]>
Gesendet: Dienstag, 18. August 2020 11:41
An: Iburg Andreas <[email protected]>
Betreff: EXT: Bajrawia Problem
EXTERNAL SENDER
Good morning
MR. Andreas
Bajrawia engineer contacted me and told me that the powder code does not work with the wire he is using .. because he
uses F7A8, AWS A-5.17, 30 KG .. You sent F7A4 powder, AWS A 5.17 .. We expect a problem with the customer ..
Please explain how to treat this the problem.
Best Regards
Mohammed