Hws-A e PDF
Hws-A e PDF
Hws-A e PDF
PC Board
Contents
● HWS-A/HD ☞ a_HWS-A_15 Page
● HWS-A/ME ☞ a_HWS-A_25 Page
● Block Diagram, Sequence Time Chart ☞ a_HWS-A_35 Page
● Instruction Manual ☞ a_HWS-A_37 Page
HWS-A
HWS-A
■ Product Line up
15W 30W 50W 80W 100W 150W
Output
Voltage Output Output Output Output Output Output
MODEL MODEL MODEL MODEL MODEL MODEL
Current Current Current Current Current Current
3.3V 3A HWS15A-3 6A HWS30A-3 10A HWS50A-3 16A HWS80A-3 20A HWS100A-3 30A HWS150A-3
5V 3A HWS15A-5 6A HWS30A-5 10A HWS50A-5 16A HWS80A-5 20A HWS100A-5 30A HWS150A-5
12V 1.3A HWS15A-12 2.5A HWS30A-12 4.3A HWS50A-12 6.7A HWS80A-12 8.5A HWS100A-12 13A HWS150A-12
15V 1A HWS15A-15 2A HWS30A-15 3.5A HWS50A-15 5.4A HWS80A-15 7A HWS100A-15 10A HWS150A-15
24V 0.65A HWS15A-24 1.3A HWS30A-24 2.2A HWS50A-24 3.4A HWS80A-24 4.5A HWS100A-24 6.5A HWS150A-24
48V 0.33A HWS15A-48 0.65A HWS30A-48 1.1A HWS50A-48 1.7A HWS80A-48 2.1A HWS100A-48 3.3A HWS150A-48
ZHE
・All specifications are subject to change without notice.
a_HWS-A_1
HWS15A
UNIT・
HWS15
HWS15A SPECIFICATIONS (Read instruction manual carefully, before using the power supply unit.)
PC Board
MODEL
HWS15A-3 HWS15A-5 HWS15A-12 HWS15A-15 HWS15A-24 HWS15A-48
ITEMS/UNITS
Input Voltage Range (*2) V AC85 - 265 (47 - 63Hz) or DC120 - 370
Ef ciency(100VAC) (typ) (*1) % 70 77 80 81 82 82
Ef ciency(200VAC) (typ) (*1) % 71 79 83 84 85 82
Input
Input Current (100/200VAC) (typ) (*1) A 0.24/0.15 0.35/0.2
Inrush Current (100/200VAC) (typ) (*1)(*3) A 14/28 (Ta = 25℃ , Cold Start)
Leakage Current (*9) mA Less than 0.5 (0.2 (typ) at 100VAC / 0.4 (typ) at 230VAC)
Nominal Output Voltage VDC 3.3 5 12 15 24 48
Maximum Output Current A 3 3 1.3 1 0.65 0.33
Maximum Output Power W 10.0 15.0 15.6 15.0 15.6 15.8
Maximum Line Regulation (*5) mV 20 20 48 60 96 192
Maximum Load Regulation (*6) mV 40 40 96 120 150 240
Output
Temperature Coef cient Less than 0.02% /℃
Maximum Ripple & Noise(0≦Ta≦70℃ ) (*4) mV 120 120 150 150 150 200
Maximum Ripple & Noise(-10≦Ta<0℃ ) (*4) mV 160 160 180 180 180 240
Hold-up Time (typ) (*1) ms 20
Output Voltage Range VDC 2.97 - 3.96 4.0 - 6.0 9.6 - 14.4 12.0 - 18.0 19.2 - 28.8 38.4 - 52.8
3.15 ー 3.15 ー 1.36 ー 1.05 ー 0.68 ー 0.34 ー
HWS-A Over Current Protection (*7) A
Over Voltage Protection (*8) VDC 4.13 - 4.95 6.25 - 7.25 15.0 - 17.4 18.8 - 21.8 30.0 - 34.8 55.2 - 64.8
Remote Sensing -
Function Remote ON/OFF -
Parallel Operation -
Series Operation Possible
Line DIP Designed to meet SEMI-F47(200VAC Line only)
Operating Temperature (*10) ℃ -10 to +70 (-10 to +50℃ :100%, +60℃ :80%, +70℃ :60%)
Storage Temperature ℃ -30 to +85
Operating Humidity % RH 30 - 90(No Condensing)
Environment Storage Humidity % RH 10 - 95(No Condensing)
At no operating, 10-55Hz(Sweep for 1min)19.6m/s Constant, X,Y,Z 1hour each.
2
Vibration
2
Shock Less than 196.1m/s
Cooling Convection Cooling
Input - FG : 2kVAC (20mA), Input - Output : 3kVAC (20mA)
Withstand Voltage
Isolation Output - FG : 500VAC (20mA) for 1min
Isolation Resistance More than 100MΩ at 25℃ and 70%RH Output - FG : 500VDC
Approved by UL62368-1, CSA62368-1, EN62368-1, UL60950-1, CSA60950-1, EN60950-1.
Safety (Expire date of 60950-1: 20/12/2020) Designed to meet Den-an Appendix 8 at 100VAC only.
With cover type only: Approved by UL508, CSA C22.2 No.107.1-01.
Standards
PFHC Designed to meet IEC61000-3-2
Conducted Emission, Radiated Emission (*11) Designed to meet EN55011/EN55032-B, FCC-B, VCCI-B
Immunity (*11) Designed to meet IEC61000-6-2 IEC61000-4-2, -3, -4, -5, -6, -8, -11
Weight (typ) g 160 (With cover: 190)
Mechanical
Size (W x H x D) mm 26.5 x 82 x 80(Refer to Outline Drawing)
(*1) At 100VAC/200VAC, Ta=25℃ , nominal output voltage and maximum output power.
(*2) For cases where conformance to various safety specs (UL, CSA, EN) are required, to be described as 100 -
●Recommended EMC Filter
240VAC(50 - 60Hz).
(*3) Not applicable for the inrush current to Noise Filter for less than 0.2ms.
(*4) Measure with JEITA RC-9131B probe, Bandwidth of scope :100MHz.
For start up at low ambient temperature and low input voltage, output ripple noise might not meet speci cation.
However, speci cation can be met after one second.
(*5) 85 - 265VAC, constant load.
(*6) No load-Full load, constant input voltage.
(*7) Hiccup with automatic recovery. Avoid to operate at over load or short circuit condition. RSEN-2003D or RSEN-2003
(*8) OVP circuit will shut down output, manual reset (Re power on). Please refer to "TDK-Lambda
(*9) Measured by the each measuring method of UL, CSA, EN and Den-an (at 60Hz), Ta=25℃ . EMC Filters" catalog.
(*10) Output Derating
- Refer to Output Derating Curve.
- Load (%) is percent of maximum output power or maximum output current, do not exceed its derating
of maximum load.
(*11) The power supply is considered a component which will be installed into a nal equipment.
The nal equipment should be re-evaluated that it meets EMC directives.
Outline Drawing
UNIT・
PC Board
【HWS15A】
5-M3.5
COVER
([/A]TYPE)
+V
7.3
-V
82±1
68±0.5
FG (67.5)
AC(L)
8.4
AC(N)
(17)
8
(14) (10) 62±0.5 8
NAME PLATE
17
15
[unit: mm]
Output Derating
●HWS15A ●HWS15A/A (WITH COVER) (OPTIONS/ADDIN INCLUDING)
120 120
100 100
90
80 80
LOAD (%)
LOAD (%)
60 60
40 40
20 20 MOUNTING (A)
MOUNTING (A), (B), (C), (D) MOUNTING (B), (C), (D)
0 0
-10 0 10 20 30 40 50 60 70 80 -10 0 10 20 30 40 50 60 70 80
Ta (°C) Ta (°C)
MOUNTING A
(STANDARD MOUNTING) MOUNTING B MOUNTING C MOUNTING D DON’T USE
UNIT・
HWS30
HWS30
HWS30A SPECIFICATIONS (Read instruction manual carefully, before using the power supply unit.)
PC Board
Outline Drawing
UNIT・
PC Board
【HWS30A】
(10.1) VOLTAGE ADJUSTMENT 2-M3 TAPPED HOLES
SCREW PENETRATION DEPTH MAX. 6mm
LED (GREEN)
5-M3.5
COVER
([/A]TYPE)
+V
68±0.5
7.3
82±1
-V
(67.5)
FG
AC(L)
8.4
AC(N)
(17)
8
(14) (10) 77±0.5 8
NAME PLATE
17
15
[unit: mm]
Output Derating
●HWS30A ●HWS30A/A (WITH COVER) (OPTIONS/ADDIN INCLUDING)
120 120
100 100
80 80
LOAD (%)
LOAD (%)
60 60
40 40
20 20 MOUNTING (A)
MOUNTING (A), (B), (C), (D) MOUNTING (B), (C), (D)
0 0
-10 0 10 20 30 40 50 60 70 80 -10 0 10 20 30 40 50 60 70 80
Ta (°C) Ta (°C)
MOUNTING A
(STANDARD MOUNTING) MOUNTING B MOUNTING C MOUNTING D DON’T USE
UNIT・
HWS50
HWS50A SPECIFICATIONS (Read instruction manual carefully, before using the power supply unit.)
PC Board
HWS-A Output Voltage Range VDC 2.97 - 3.96 4.0 - 6.0 9.6 - 14.4 12.0 - 18.0 19.2 - 28.8 38.4 - 52.8
Over Current Protection (*7) A 10.5 - 10.5 - 4.51 - 3.67 - 2.31 - 1.15 -
Over Voltage Protection (*8) VDC 4.13 - 4.95 6.25 - 7.25 15.0 - 17.4 18.8 - 21.8 30.0 - 34.8 55.2 - 64.8
Remote Sensing -
Function Remote ON/OFF - (/R Option: Output ON in the external voltage is applied)
Parallel Operation -
Series Operation Possible
Line DIP Designed to meet SEMI-F47(200VAC Line only)
Operating Temperature (*10) ℃ -10 to +70 (-10 to +50℃ :100%, +60℃ :70%, +70℃ :40%)
Storage Temperature ℃ -30 to +85
Operating Humidity % RH 30 - 90(No Condensing)
Environment Storage Humidity % RH 10 - 95(No Condensing)
At no operating, 10-55Hz(Sweep for 1min)19.6m/s Constant, X,Y,Z 1hour each.
2
Vibration
2
Shock Less than 196.1m/s
Cooling Convection Cooling
Input - FG : 2kVAC (20mA), Input - Output : 3kVAC (20mA)
Withstand Voltage
Isolation Output - FG : 500VAC (20mA) for 1min
Isolation Resistance More than 100MΩ at 25℃ and 70%RH Output - FG : 500VDC
Approved by UL62368-1, CSA62368-1, EN62368-1, UL60950-1, CSA60950-1, EN60950-1.
Safety (Expire date of 60950-1: 20/12/2020) Designed to meet Den-an Appendix 8 at 100VAC only.
With cover type only: Approved by UL508, CSA C22.2 No.107.1-01.
Outline Drawing
UNIT・
PC Board
(10.1) /B (OPTION)
(4.8) 2-M3 TAPPED HOLES 5MAX
LED (GREEN) SCREW PENETRATION DEPTH MAX. 6mm CONNECTOR
+R -R
5-M3.5 1 2
COVER CN51
([/A]TYPE) 4
+V 3
+V
2
68±0.5
-V
82±1
-V
7.3
(75.5)
(67.5)
FG 5 FG
AC(L) 3 AC(L)
8.4
AC(N) 1 AC(N)
CN1
(17)
8
(14) (15) 97±0.5 8
NAME PLATE
HWS-A
17
15
[unit: mm]
(5) 105±0.5 10
(5.5)
Output Derating
●HWS50A(Including options model/R, /B) ●HWS50A/A (WITH COVER) (Including options model/RA, /ADDIN)
120 MOUNTING (A) 120 MOUNTING (A)
MOUNTING (B), (D) MOUNTING (B), (D)
100 MOUNTING (C)
100 MOUNTING (A)
86
80 80
LOAD (%)
LOAD (%)
76
70 73
65
60 60
58 53
46
40 40
30 30
20 20
0 0
-10 0 10 20 30 40 45 50 60 70 80 -10 0 10 20 30 40 50 60 70 80
Ta (°C) Ta (°C)
MOUNTING A MOUNTING B
(STANDARD MOUNTING)
DON’T USE
MOUNTING C MOUNTING D
UNIT・
HWS100
HWS80A SPECIFICATIONS (Read instruction manual carefully, before using the power supply unit.)
PC Board
HWS-A Output Voltage Range VDC 2.97 - 3.96 4.0 - 6.0 9.6 - 14.4 12.0 - 18.0 19.2 - 28.8 38.4 - 52.8
Over Current Protection (*7) A 16.8 - 16.8 - 7.04 - 5.67 - 3.57 - 1.79 -
Over Voltage Protection (*8) VDC 4.13 - 4.95 6.25 - 7.25 15.0 - 17.4 18.8 - 21.8 30.0 - 34.8 55.2 - 64.8
Remote Sensing Possible
Function Remote ON/OFF - (/R Option: Output ON in the external voltage is applied)
Parallel Operation -
Series Operation Possible
Line DIP Designed to meet SEMI-F47(200VAC Line only)
Operating Temperature (*10) ℃ -10 ~ +70(-10 ~ +50℃ :100%, +60℃ :80%, +70℃ :60%)
Storage Temperature ℃ -30 to +85
Operating Humidity % RH 30 - 90(No Condensing)
Environment Storage Humidity % RH 10 - 95(No Condensing)
At no operating, 10-55Hz(Sweep for 1min) 19.6m/s Constant, X,Y,Z 1hour each.
2
Vibration
2
Shock Less than 196.1m/s
Cooling Convection Cooling
Input - FG : 2kVAC (20mA), Input - Output : 3kVAC (20mA)
Withstand Voltage
Isolation Output - FG : 500VAC (20mA) for 1min
Isolation Resistance More than 100MΩ at 25℃ and 70%RH Output - FG : 500VDC
Approved by UL62368-1, CSA62368-1, EN62368-1, UL60950-1, CSA60950-1, EN60950-1.
Safety (Expire date of 60950-1: 20/12/2020) Designed to meet Den-an Appendix 8 at 100VAC only.
With cover type only: Approved by UL508, CSA C22.2 No.107.1-01.
Standards
PFHC Designed to meet IEC61000-3-2
Conducted Emission, Radiated Emission (*11) Designed to meet EN55011/EN55032-B, FCC-B, VCCI-B
Immunity (*11) Designed to meet IEC61000-6-2 IEC61000-4-2, -3, -4, -5, -6, -8, -11
Weight (typ) g 420 (With cover: 470)
Mechanical
Size (W x H x D) mm 28 x 82 x 160(Refer to Outline Drawing)
(*1) At 100VAC/200VAC, Ta=25℃ , nominal output voltage and maximum output power.
(*2) For cases where conformance to various safety specs (UL, CSA, EN) are required, to be described as 100 - ●Recommended EMC Filter
240VAC(50 - 60Hz).
(*3) Not applicable for the inrush current to Noise Filter for less than 0.2ms.
(*4) Measure with JEITA RC-9131B probe, Bandwidth of scope :100MHz.
(*5) 85 - 265VAC, constant load.
(*6) No load-Full load, constant input voltage.
(*7) Constant current limit and hiccup with automatic recovery.
Avoid to operate at over load or short circuit condition.
(*8) OVP circuit will shut down output, manual reset (Re power on).
RSEN-2003D or RSEN-2003
(*9) Measured by the each measuring method of UL, CSA, EN and Den-an (at 60Hz), Ta=25℃ .
(*10) Output Derating Please refer to "TDK-Lambda
- Refer to Output Derating Curve. EMC Filters" catalog.
- Load (%) is percent of maximum output power or maximum output current, do not exceed its derating
of maximum load.
(*11) The power supply is considered a component which will be installed into a nal equipment.
The nal equipment should be re-evaluated that it meets EMC directives.
Outline Drawing
UNIT・
PC Board
COVER 2 -R
7-M3.5 ([/A]TYPE) 1 +R
CN51
8.6
+S 6
5 +V
4
+V 3
-V
10
2
68±0.5
-V 1
82±1
9.2
(75)
-S
7.3
FG 5 FG
AC(L) 3 AC(L)
8.4
AC(N) 1 AC(N)
CN1
(9)
8
(14) (17) 135±0.5 8
NAME PLATE
17
15.5
(15) 125±0.5 20
(5.5)
Output Derating
●HWS80A(Including options model/R, /B) ●HWS80A/A (WITH COVER) (Including options model/RA, /ADDIN)
120 MOUNTING (A) 120 MOUNTING (A)
MOUNTING (B) MOUNTING (B), (D)
100 100
MOUNTING (C), (D) MOUNTING (C)
90 90
86
80 80
LOAD (%)
LOAD (%)
70 70
60 60
50
40 40
20 20
0 0
-10 0 10 20 30 40 45 50 60 70 80 -10 0 10 20 30 40 45 50 60 70 80
Ta (°C) Ta (°C)
MOUNTING A MOUNTING B
(STANDARD MOUNTING)
DON’T USE
MOUNTING C MOUNTING D
UNIT・
HWS100A SPECIFICATIONS (Read instruction manual carefully, before using the power supply unit.)
PC Board
HWS-A Output Voltage Range VDC 2.97 - 3.96 4.0 - 6.0 9.6 - 14.4 12.0 - 18.0 19.2 - 28.8 38.4 - 52.8
Over Current Protection (*7) A 21.0 - 21.0 - 8.92 - 7.35 - 4.72 - 2.20 -
Over Voltage Protection (*8) VDC 4.13 - 4.95 6.25 - 7.25 15.0 - 17.4 18.8 - 21.8 30.0 - 34.8 55.2 - 64.8
Remote Sensing Possible
Function Remote ON/OFF - (/R Option: Output ON in the external voltage is applied)
Parallel Operation -
Series Operation Possible
Line DIP Designed to meet SEMI-F47(200VAC Line only)
Operating Temperature (*10) ℃ -10 to +70 (-10 to +50℃ :100%, +60℃ :65%, +70℃ :30%)
Storage Temperature ℃ -30 to +85
Operating Humidity % RH 30 - 90(No Condensing)
Environment Storage Humidity % RH 10 - 95(No Condensing)
At no operating, 10-55Hz(Sweep for 1min) 19.6m/s Constant, X,Y,Z 1hour each.
2
Vibration
2
Shock Less than 196.1m/s
Cooling Convection Cooling
Input - FG : 2kVAC (20mA), Input - Output : 3kVAC (20mA)
Withstand Voltage
Isolation Output - FG : 500VAC (20mA) for 1min
Isolation Resistance More than 100MΩ at 25℃ and 70%RH Output - FG : 500VDC
Approved by UL62368-1, CSA62368-1, EN62368-1, UL60950-1, CSA60950-1, EN60950-1.
Safety (Expire date of 60950-1: 20/12/2020) Designed to meet Den-an Appendix 8 at 100VAC only.
With cover type only: Approved by UL508, CSA C22.2 No.107.1-01.
Standards
PFHC Designed to meet IEC61000-3-2
Conducted Emission, Radiated Emission (*11) Designed to meet EN55011/EN55032-B, FCC-B, VCCI-B
Immunity (*11) Designed to meet IEC61000-6-2 IEC61000-4-2, -3, -4, -5, -6, -8, -11
Weight (typ) g 420 (With cover: 470)
Mechanical
Size (W x H x D) mm 28 x 82 x 160(Refer to Outline Drawing)
(*1) At 100VAC/200VAC, Ta=25℃ , nominal output voltage and maximum output power.
(*2) For cases where conformance to various safety specs (UL, CSA, EN) are required, to be described as 100 - ●Recommended EMC Filter
240VAC(50 - 60Hz).
(*3) Not applicable for the inrush current to Noise Filter for less than 0.2ms.
(*4) Measure with JEITA RC-9131B probe, Bandwidth of scope :100MHz.
(*5) 85 - 265VAC, constant load.
(*6) No load-Full load, constant input voltage.
(*7) Constant current limit and hiccup with automatic recovery.
Avoid to operate at over load or short circuit condition.
(*8) OVP circuit will shut down output, manual reset (Re power on).
RSEN-2003D or RSEN-2003
(*9) Measured by the each measuring method of UL, CSA, EN and Den-an (at 60Hz), Ta=25℃ .
(*10) Output Derating Please refer to "TDK-Lambda
- Refer to Output Derating Curve. EMC Filters" catalog.
- Load (%) is percent of maximum output power or maximum output current, do not exceed its derating
of maximum load.
(*11) The power supply is considered a component which will be installed into a nal equipment.
The nal equipment should be re-evaluated that it meets EMC directives.
COVER 2 -R
7-M3.5 ([/A]TYPE) 1 +R
CN51
8.6
+S 6
5 +V
4
+V 3
-V
10
2
68±0.5
-V 1
82±1
9.2
(75)
-S
7.3
FG 5 FG
AC(L) 3 AC(L)
8.4
AC(N) 1 AC(N)
CN1
(9)
8
(14) (17) 135±0.5 8
NAME PLATE
17
15.5
(15) 125±0.5 20
(5.5)
Output Derating
●HWS100A(Including options model/R, /B) ●HWS100A/A (WITH COVER) (Including options model/RA, /ADDIN)
MOUNTING (A)
120 MOUNTING (A) 120
MOUNTING (B)
MOUNTING (B)
100 100 MOUNTING (C)
MOUNTING (C), (D) 92
MOUNTING (D)
80 80
LOAD (%)
LOAD (%)
65 65
60 60
42
40 40
37
30
20 20
10
0 0
-10 0 10 20 30 40 50 60 70 80 -10 0 10 20 30 35 40 50 60 70 80
Ta (°C) Ta (°C)
Refer to dotted line for output derating curve, when input voltage range
is "85VAC≦Vin<90VAC" for the Mounting (A).
MOUNTING A MOUNTING B
(STANDARD MOUNTING)
DON’T USE
MOUNTING C MOUNTING D
UNIT・
HWS150
HWS150A SPECIFICATIONS (Read instruction manual carefully, before using the power supply unit.)
PC Board
HWS-A Output Voltage Range VDC 2.97 - 3.96 4.0 - 6.0 9.6 - 14.4 12.0 - 18.0 19.2 - 28.8 38.4 - 52.8
Over Current Protection (*7) A 31.5 - 31.5 - 13.6 - 10.5 - 6.82 - 3.46 -
Over Voltage Protection (*8) VDC 4.13 - 4.95 6.25 - 7.25 15.0 - 17.4 18.8 - 21.8 30.0 - 34.8 55.2 - 64.8
Remote Sensing Possible
Function Remote ON/OFF - (/R Option: Output ON in the external voltage is applied)
Parallel Operation -
Series Operation Possible
Line DIP Designed to meet SEMI-F47(200VAC Line only)
Operating Temperature (*10) ℃ -10 to +70 (-10 to +50℃ :100%, +60℃ :60%, +70℃ :20%)
Storage Temperature ℃ -30 to +85
Operating Humidity % RH 30 - 90(No Condensing)
Environment Storage Humidity % RH 10 - 95(No Condensing)
At no operating, 10-55Hz(Sweep for 1min)19.6m/s Constant, X,Y,Z 1hour each.
2
Vibration
2
Shock Less than 196.1m/s
Cooling Convection Cooling
Input - FG : 2kVAC (20mA), Input - Output : 3kVAC (20mA)
Withstand Voltage
Isolation Output - FG : 500VAC (20mA) for 1min
Isolation Resistance More than 100MΩ at 25℃ and 70%RH Output - FG : 500VDC
Approved by UL62368-1, CSA62368-1, EN62368-1, UL60950-1, CSA60950-1, EN60950-1.
Safety (Expire date of 60950-1: 20/12/2020) Designed to meet Den-an Appendix 8 at 100VAC only.
With cover type only: Approved by UL508, CSA C22.2 No.107.1-01.
Standards
PFHC Designed to meet IEC61000-3-2
Conducted Emission, Radiated Emission (*11) Designed to meet EN55011/EN55032-B, FCC-B, VCCI-B
Immunity (*11) Designed to meet IEC61000-6-2 IEC61000-4-2, -3, -4, -5, -6, -8, -11
Weight (typ) g 470 (With cover: 520)
Mechanical
Size (W x H x D) mm 37 x 82 x 160(Refer to Outline Drawing)
(*1) At 100VAC/200VAC, Ta=25℃ , nominal output voltage and maximum output power.
(*2) For cases where conformance to various safety specs (UL, CSA, EN) are required, to be described as 100 - ●Recommended EMC Filter
240VAC(50 - 60Hz).
(*3) Not applicable for the inrush current to Noise Filter for less than 0.2ms.
(*4) Measure with JEITA RC-9131B probe, Bandwidth of scope :100MHz.
(*5) 85 - 265VAC, constant load.
(*6) No load-Full load, constant input voltage.
(*7) Constant current limit and hiccup with automatic recovery.
Avoid to operate at over load or short circuit condition.
(*8) OVP circuit will shut down output, manual reset (Re power on).
RSEN-2003D or RSEN-2003
(*9) Measured by the each measuring method of UL, CSA, EN and Den-an (at 60Hz), Ta=25℃ .
(*10) Output Derating Please refer to "TDK-Lambda
- Refer to Output Derating Curve. EMC Filters" catalog.
- Load (%) is percent of maximum output power or maximum output current, do not exceed its derating
of maximum load.
(*11) The power supply is considered a component which will be installed into a nal equipment.
The nal equipment should be re-evaluated that it meets EMC directives.
Outline Drawing
UNIT・
PC Board
7-M3.5 COVER 2 -R
([/A]TYPE) 1 +R
CN51
8.6
+S 6
5 +V
+V 4
3
10
2 -V
68±0.5
-V
82±1
9.2 1
(75)
-S
7.3
FG 5 FG
AC(L) 3 AC(L)
8.4
AC(N) 1 AC(N)
CN1
(9)
8
(14.6) (17) 135±0.5 8
NAME PLATE
HWS-A
17
18.5
(15) 131±0.5 14
(6.1)
[unit: mm]
Recommended Solderless Terminal
Terminal
D(max) t(max) Qty(max) /B (Option) Use connector
0.8mm 2 pcs PART DESCRIPTION PART NAME MANUFACT QTY
8.1mm
1.0mm 1 pcs CONNECTOR INPUT SIDE(CN1) (LF(
B3 P5 -VH )SN) JST 1
Others 6.8mm 0.8mm 2 pcs CONNECTOR OUTPUT SIDE(CN51) B6 P-VH(LF(
)SN) JST 1
※Output terminal, please use one pin per 5A below.
/R (Option)
Remote ON / OFF control connector (JST) /B (Option) Recommended connector (it is not affixed to the product)
PIN HEADER B2B-XH-AM PART DESCRIPTION PART NAME MANUFACT QTY
SOCKET HOUSING XHP-2 SOCKET HOUSING (CN1) VHR-5N JST 1
TERMINAL PINS BXH-001T-P0.6 or SXH-001T-P0.6 SOCKET HOUSING (CN51) VHR-6N JST 1
HAND CRIMRING TOOL YC-110R or YRS-110 TERMINAL PINS (CN1,CN51) BVH-21T-P1.1 or SVH-21T-P1.1 JST 9
※ Housing and terminal pin are not attached to the product. HAND CRIMRING TOOL: YC-160R (JST)
Output Derating
●HWS150A(Including options model/R, /B) ●HWS150A/A (WITH COVER) (Including options model/RA, /ADDIN)
MOUNTING (A)
120 120
MOUNTING (B), (C), (D)
100 100
90
80 80
LOAD (%)
LOAD (%)
60 60
40 MOUNTING (A) 40
35
MOUNTING (B)
20 20
MOUNTING (C), (D) 10
0 0
-10 0 10 20 30 40 50 60 70 80 -10 0 10 20 30 40 50 60 70 80
Ta (°C) Ta (°C)
In the case of using at the input voltage range "85 VAC ≦ Vin <90VAC",
output derating will be dashed line. (Mounting direction(A) only)
MOUNTING A MOUNTING B
(STANDARD MOUNTING) DON’T USE
MOUNTING C MOUNTING D
Inrush Current
Limit Circuit
Switching Circuit
Filter Circuit
Line Filter
Input Output
85 -265VAC
OCP
Circuit
Control Circuit
Circuit Coupler Sensing
Photo- Output
Coupler Sensing
【HWS50A】
Inrush Current Limit Circuit
Switching Circuit
PFHC Circuit
Filter Circuit
Line Filter
Input
85 -265VAC
Output HWS-A
OCP
Circuit
Control Circuit
Photo- Output
Coupler Sensing
【HWS80A - HWS150A】
Inrush Current Limit Circuit
Switching Circuit
PFHC Circuit
Filter Circuit
Line Filter
Input Output
85 -265VAC
OCP
Circuit
Control Circuit
Photo- Output
Coupler Sensing
UNIT・
Sequence Time Chart
PC Board
【HWS15A, HWS30A】
Input Voltage
OVP Point(∗1)
Output Voltage
OVP ACT ON
INPUT OFF
INPUT ON
OCP ACT ON
OCP RESET
INPUT OFF
【HWS50A - HWS150A】
Input Voltage
OVP Point(∗1)
HWS-A
(∗1) OVP Point
Output Voltage 3V : 125 - 150%
5 - 48V : 125 - 145%
Remote ON/OFF
Control(∗2)
REMOTE OFF
REMOTE ON
OVP ACT ON
INPUT OFF
INPUT ON
OCP ACT ON
OCP RESET
INPUT OFF
4.5V or higher : ON
0.8V or less: OFF
Be sure to read this instruction manual thoroughly before using this product. Pay attention to all cautions and
warnings before using this product.
HWS-A
取扱説明
1.The contents of this catalog are subject to change without notice, for example related to product improvements and
other instances. Always check the latest information before deciding on a product.
2.Our products are designed and manufactured under the assumption that they will be used as integrated power
supplies for normal industrial applications. They are not designed and manufactured for use in high-safety
applications (applications requiring very high reliability and safety levels, where a reliability or safety problem could
directly involve the risk of serious injury or death). If the customer decides to use our products in a high-safety
application, appropriate fail-safe design features must be provided (such as incorporating protective circuitry and/or
protective equipment in the system, or incorporating redundancy in the system so that a single failure cannot lead to
instability). TDK-Lambda Corporation does not assume liability for any claims or damages either by the customer or
third parties arising from the use of our products for high-safety applications.
3.When designing equipment in which our products are to be used, as well as peripheral circuitry for such equipment,
always observe the "Product Usage Precautions" noted in this catalog and/or the product documentation and ensure
that maximum ratings, power supply voltage range, operation temperature range and other specifications are not
exceeded. TDK-Lambda Corporation does not assume liability for any claims or damages arising from the use of our
products in a way that exceeds specifications, or from a type of usage indicated as unsuitable for the respective
product in this catalog.
4.The operation outline and usage descriptions given in this catalog are examples. Before actual use of a product, all
external factors must be examined carefully in order to ensure appropriate circuit and implementation design.
TDK-Lambda Corporation does not assume liability for any claims or damages arising from indirect problems such as
EMI or mechanical effects from our products.
5.The technical information included in this catalog is intended only for the purpose of illustrating representative
operation or application of our products. It does not imply any guarantee or granting of license for intellectual
property rights or other rights held either by TDK-Lambda Corporation or third parties. TDK-Lambda Corporation does
not assume liability for any problems with third parties related to intellectual property rights arising from the use of our
products.
6.Products listed in this catalog may require export permission or authorization in compliance with the Foreign
Exchange and Foreign Trade Act.
7.The contents of this catalog may not be reproduced or copied without permission by TDK-Lambda Corporation.
8.For any inquiries regarding this catalog, please contact the Sales Department of TDK-Lambda Corporation.
HWS-A_1905E