HWS Series: Single Output Industrial Power Supplies

The document describes the HWS Series of single output industrial power supplies from TDK-Lambda. The HWS Series includes power supply models ranging from 15W to 150W, with output voltages of 3.3V, 5V, 12V, 15V, 24V and 48V. The power supplies have features such as a limited lifetime warranty, UL508 approval, universal AC input range of 85-265V, and operating temperature range of -10°C to +70°C. They are intended for applications in industrial equipment and factory automation.

Uploaded by

Steve
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
117 views2 pages

HWS Series: Single Output Industrial Power Supplies

The document describes the HWS Series of single output industrial power supplies from TDK-Lambda. The HWS Series includes power supply models ranging from 15W to 150W, with output voltages of 3.3V, 5V, 12V, 15V, 24V and 48V. The power supplies have features such as a limited lifetime warranty, UL508 approval, universal AC input range of 85-265V, and operating temperature range of -10°C to +70°C. They are intended for applications in industrial equipment and factory automation.

Uploaded by

Steve
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

HWS Series

Single Output Industrial Power Supplies


Features
 Limited Lifetime Warranty
 UL508 approved
 SEMI F47 Compliant (high line AC)
 Universal Input (85 - 265VAC)
 High Efficiency
 Wide Range AC Input

Key Market Segments & Applications

Specifications
Model HWS15 HWS30 HWS50 HWS100 HWS150
Input Voltage range - 85 - 265VAC (47 - 63Hz) or 120 - 370VDC
Input Current (Typ) (1) A 0.4 / 0.2 0.8 / 0.4 0.7 / 0.35 1.3 / 0.65 1.9 / 0.95
Inrush Current (1) A 14 / 28
Power Factor - Meets EN61000-3-2
Temperature Coefficient - <0.02%/°C
Overcurrent Protection - >104%
Overvoltage Protection V Yes (See page 2)
Hold Up Time (Typ) ms 20
Leakage Current (max) mA <0.5mA (Typ 0.3mA at 100VAC, 0.5mA at 230VAC)
Remote Sense - No Yes
Indicator - Green LED = ON
Operating Temperature (no cover) °C -10°C to +70°C, derate linearly to 20% load from 50°C to 70°C (2)
Storage Temperature °C -30 to +85°C
Humidity (non condensing) - Operating: 30 - 90%RH, Non operating 10 - 95%RH
Cooling - Convection
Withstand Voltage - Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
Isolation Resistance - >100M at 25°C & 70%RH, Output to Ground 500VDC
Vibration (non operating) - 10 - 55Hz (1 minute sweep), 19.6m/s2 constant X, Y, Z 1 hour
Shock - < 196.1m/s2
Safety Agency Certifications - UL60950-1, CSA60950-1, EN60950-1, EN50178, UL508, CE Mark (3)
Line Dip - Complies with SEMI F47 (200VAC line only)
Conducted & Radiated EMI - EN55011 / EN55022-B, FCC-B, VCCI-B
Recommended EMI Filter - RSEL-2001W RSEL-2002W RSEL-2003W
Immunity - IEC61000-4-2 (Level 3,2), -3, -4, -5, -6 (Level 3), -8, -11 (Level 4)
Weight (Typ) g 180 220 280 450 500
Size (WxHxD) in 1.04x3.23x3.15 1.04x3.23x3.74 1.04x3.23x4.72 1.1x3.23x6.3 1.46x3.23x6.3
Size (WxHxD) /A version 1.24x3.23x3.15 1.24x3.23x3.74 1.24x3.23x4.72 1.3x3.23x6.3 1.65x3.23x6.3
Warranty yrs Limited lifetime warranty (See Lambda’s terms & conditions)
(1) 100/200VAC
(2) -40°C Start up, see options table
(3) UL60601-1, EN60601-1, see options table

1-800-526-2324 • www.us.tdk-lambda.com/lp/ 97 Disclaimer: us.tdk-lambda.com/lp/legal.htm


HWS Series
Output Ratings HWS15 Outline Drawing
Max Load Line Ripple Over Eff.
Adjust Curr. Reg Reg Noise voltage typ
Model Voltage Range A mV mV mV V % (1)
HWS15-3/A 3.3V 2.97 - 3.96 3 40 20 120 4.13-4.95 68/71
HWS30-3/A 3.3V 2.97 - 3.96 6 40 20 120 4.13-4.95 70/73
HWS50-3/A 3.3V 2.97 - 3.96 10 40 20 120 4.13-4.95 76/78
HWS100-3/A 3.3V 2.97 - 3.96 20 40 20 120 4.13-4.95 78/81
HWS150-3/A 3.3V 2.97 - 3.96 30 40 20 120 4.13-4.95 78/81
HWS15-5/A 5V 4.0 - 6.0 3 40 20 120 6.25-7.25 77/79
HWS30-5/A 5V 4.0 - 6.0 6 40 20 120 6.25-7.25 77/80
HWS50-5/A 5V 4.0 - 6.0 10 40 20 120 6.25-7.25 82/84
HWS100-5/A 5V 4.0 - 6.0 20 40 20 120 6.25-7.25 83/86
HWS150-5/A 5V 4.0 - 6.0 30 40 20 120 6.25-7.25 83/86
HWS15-12/A 12V 9.6 - 14.4 1.3 96 48 150 15-17.4 80/81
HWS30-12/A 12V 9.6 - 14.4 2.5 96 48 150 15-17.4 81/83
HWS50-12/A 12V 9.6 - 14.4 4.3 96 48 150 15-17.4 81/83
HWS100-12/A 12V 9.6 - 14.4 8.5 96 48 150 15-17.4 83/86
HWS150-12/A 12V 9.6 - 14.4 13 96 48 150 15-17.4 83/86
HWS15-15/A 15V 12.0 - 18.0 1 120 60 150 18.8-21.8 80/81
HWS30-15/A 15V 12.0 - 18.0 2 120 60 150 18.8-21.8 81/83
HWS50-15/A 15V 12.0 - 18.0 3.5 120 60 150 18.8-21.8 81/83
HWS100-15/A 15V 12.0 - 18.0 7 120 60 150 18.8-21.8 83/86
HWS150-15/A 15V 12.0 - 18.0 10 120 60 150 18.8-21.8 83/86
HWS15-24/A 24V 19.2 - 28.8 0.65 192 96 200 30-34.8 82/83
HWS30-24/A 24V 19.2 - 28.8 1.3 192 96 200 30-34.8 83/86
HWS50-24/A 24V 19.2 - 28.8 2.2 192 96 150 30-34.8 82/84
HWS100-24/A 24V 19.2 - 28.8 4.5 192 96 150 30-34.8 84/87
HWS150-24/A 24V 19.2 - 28.8 6.5 192 96 150 30-34.8 85/88
HWS15-48/A 48V 38.4 - 52.8 0.33 384 192 200 55.2-64.8 80/80
HWS30-48/A
HWS50-48/A
48V 38.4 - 52.8
48V 38.4 - 52.8
0.65
1.1
384
384
192
192
200
200
55.2-64.8
55.2-64.8
82/83
83/85
HWS150 Outline Drawing
HWS100-48/A 48V 38.4 - 52.8 2.1 384 192 200 55.2-64.8 84/87
HWS150-48/A 48V 38.4 - 52.8 3.3 384 192 200 55.2-64.8 85/88

Options
Suffix Description
Blank Screw terminals, no cover
/A Screw terminals, cover
/R Remote on/off (50-150W only)
/HD See HWS50-1500/HD Datasheet for details. -40 to
+71(74)°C operation, conformally coated PCBs
/ME See HWS30-1500/ME Datasheet for details.
UL60601-1, EN60601-1 medical approvals

Example: HWS50-24/RA

Other Industrial Products For Additional Information, please visit


us.tdk-lambda.com/lp/products/hws-series.htm
HWS300-1800 300 to 1800W
LZSA 500W to 1500W Single output
DPP, DLP & DSP 10W to 480W DIN Rail Mount

1-800-526-2324 • www.us.tdk-lambda.com/lp/ 98 Revision B6: Feb 2019