0% found this document useful (0 votes)
318 views1 page

Load Combo

The document outlines load combinations for structural design based on different codes: - BNBC steel structure load combinations with and without floor live loads - BNBC RCC load combinations - NTPA RCC and steel load combinations - ACCORD RCC and steel load combinations It also provides minimum material properties that can be assumed for reinforced concrete and steel elements if actual testing has not been performed, including minimum compressive strengths, reinforcing steel yields, and assumed concrete density.

Uploaded by

masud parveg
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
318 views1 page

Load Combo

The document outlines load combinations for structural design based on different codes: - BNBC steel structure load combinations with and without floor live loads - BNBC RCC load combinations - NTPA RCC and steel load combinations - ACCORD RCC and steel load combinations It also provides minimum material properties that can be assumed for reinforced concrete and steel elements if actual testing has not been performed, including minimum compressive strengths, reinforcing steel yields, and assumed concrete density.

Uploaded by

masud parveg
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 1

BNBC STEEL STRUCTURE LOAD COMBINATION FOR FLOOR LIVE LOAD

1. 1.4DL
2. 1.2DL+1.6LF+0.5LR
3. 1.2DL+0.5LF+1.6LR
4. 1.2DL+1.6LR+0.7WIND
5. 1.2DL+0.5LF+0.5LR+1.3WIND
6. 1.2DL+0.5LF+1.5EQ
7. 0.9DL+1.3WIND
8. 0.9DL+1.5EQ

BNBC STEEL STRUCTURE LOAD COMBINATION WITHOUT FLOOR LIVE LOAD


1. 1.4DL
2. 1.2DL+0.5LR
3. 1.2DL+1.6LR
4. 1.2DL+1.6LR+0.7WIND
5. 1.2DL+0.5LR+1.3WIND
6. 1.2DL+1.5EQ
7. 0.9DL+1.3WIND
8. 0.9DL+1.5EQ

BNBC RCC LOAD COMBINATION


1. 1.4DL
2. 1.4DL+1.7LL
3. 0.9DL+1.3WIND
4. 0.9DL+1.43EQ
5. 1.05DL+1.275WIND
6. 1.05DL+1.4025EQ
7. 1.05DL+1.275LL+1.275WIND
8. 1.05DL+1.275LL+1.4025EQ

NTPA RCC LOAD COMBINATION


 1.2DL+1.6LL
 1.05DL+1.25LL+1.0WIND
 1.05DL+1.25LL+1.0EQ

NTPA /ACCORD STEEL LOAD COMBINATION


 1.2DL+1.6LF+0.5LR
 1.2DL+0.5LF+0.5LR+1.3WIND
 1.2DL+0.5LF+0.5LR+1.5EQ

ACCORD RCC LOAD COMBINATION


 1.2DL+1.6LL
 1.05DL+1.25LL+1.0WIND
 1.05DL+1.25LL+1.0EQ

7.3 Minimum Construction Material Properties In evaluating the structural capacity of existing structural
elements
7.3.1 Actual measured or tested properties of materials may be used for elements tested in accordance with
ASTM Standards.
7.3.2 Where testing has not been used to confirm actual properties and there is no sign of structural distress or
deficiency in the subject member, the following minimum properties may generally be used, unless good
engineering judgment indicates lesser properties should be assumed:
7.3.2.1 Reinforced concrete (stone chip)– 15.0 MPa (2200 psi)
7.3.2.2 Reinforced concrete (masonry chip)– 10.4 MPa (1500 psi)
7.3.2.3 Reinforcing steel installed prior to 2004: – 275 MPa (40 ksi)
7.3.2.4 Reinforcing steel installed from 2004 to present: – 415 MPa (60 ksi)
7.3.2.5 A36 Structural steel – 248 MPa (36 ksi) yield strength
7.4 Minimum assumed density of reinforced concrete – 23.6 kN/m3 (150 pcf)