0% found this document useful (0 votes)
86 views8 pages

Power Electronics Lab: Objectives

This document describes experiments performed on an AC static converter circuit with resistive and resistive-inductive loads. The objectives are to study the converter circuit with a resistive load (R) and a resistive-inductive load (RL). Measurements are taken of voltage and current outputs at various control angles, and control characteristics are drawn comparing theoretical predictions to experimental results.

Uploaded by

Rafey
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
86 views8 pages

Power Electronics Lab: Objectives

This document describes experiments performed on an AC static converter circuit with resistive and resistive-inductive loads. The objectives are to study the converter circuit with a resistive load (R) and a resistive-inductive load (RL). Measurements are taken of voltage and current outputs at various control angles, and control characteristics are drawn comparing theoretical predictions to experimental results.

Uploaded by

Rafey
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 8

Power Electronics Lab Lab 3

IMPLEMNTATION OF AC STATIC CONVERTER WITH RESISTIVE & RESISTIVE-


INDUCTIVE LOADS

Objectives

To carry out the experiments “AC Static converter with ohmic load (R)”.

To carry out the experiments “AC Static converter circuit with ohmic - inductive load (RL)”.

List of Equipment/Software

Following software/equipment is required:

 Supply voltage: 45 V
 Ohmic - inductive load: 33 Ω (3 x 100 Ω resistances in parallel)
 Ohmic- inductive load: 33 Ω (3 x 100 Ω resistances in parallel) and 50 mH (1 inductance in
series)
 Pulse form: “Pulse”
 Bridge topology: “735 012 – 11 W1C”
 CASSY Software

Circuit Diagram
Power Electronics Lab Lab 3

Connection Diagram

Experimental Procedure
Power Electronics Lab Lab 3

In Lab Exercise No. 01

The time profiles should be drawn for the angles 90° and 135°and described briefly. To obtain the line
diagrams below, please connect the components as per connection diagram. Open the CASSY Lab file
W1C_R_90.labx.
Measurement of us01, uV1, ud, id
us01: Line voltage
ud : DC voltage
id : DC current
uV : valve voltage

Task 1.1
Measurement of us01, uV1, ud, id at α = 90°

Results/Graphs
Power Electronics Lab Lab 3
Task 1.2
Measurement of us01, uV1, ud, id at 135°
Open the CASSY Lab file W1C_R_135.labx.

Results/Graphs
Power Electronics Lab Lab 3

In Lab Exercise No. 02

Transfer characteristic of AC Static converter circuit with ohmic load

Measure how the root-mean-square value I α is dependent on the control angle in the range from 0° …
150°. The measurements should be taken in 30° steps. Calculate the quotients of the current and draw the
control characteristic of the DC current f(α) = Id(α) / Id(α=0).

Id(α) : DC current (averaged value) depending on angle.

Evaluated Results

α/° 0 30° 60° 90° 120° 150°


°
Id(α)/V
Id(α) / Id(α=0)
Power Electronics Lab Lab 3

In Lab Exercise No. 03

Compare the controls characteristics determined for the ideal case (Theory) and for the measured values
as drawn in the fig. above.

Theoretical results

Id(α) / Id(α=0) = √ (1/π * (π - α + sin 2α ) / 2)

Id(α) / Id(α=0) ----- ----- ----- ----- ---- ---

Analysis/Discussion

In Lab Exercise No. 04

The time profiles of which have been drawn for the angles 45° and 135° are to be described briefly. To
obtain the line diagrams below, please connect the components as shown in connection diagram. Open the
CASSY lab file W1C_RL_45.labx.
Measurement of us01, ud, uv1, id.
us01 : line voltage
ud : DC voltage
id : DC current
uV1 : Valve voltage
Power Electronics Lab Lab 3

Task 4.1
Measurement of us01, ud, uv1, id.at α = 45°
Result/Graph

Task 4.2
Measurement of us01, ud, uv1, id.at α = 135°

Open the CASSY lab file W1C_RL_135.labx.

Result/Graph
Power Electronics Lab Lab 3

Analysis/Discussion