100% found this document useful (1 vote)
3K views3 pages

PMT MCQ

The document discusses various topics related to pharmaceutical manufacturing technology including: 1) Equipment used for tablet coating includes standard coating pans, perforated pan systems, and fluidized bed dryers. 2) The perforated pan system options given are Dria-coater pan, Pellegrini pan, and hi-coater pan but not the Accela-cota system. 3) One of the options given for disintegration time for uncoated tablets in the IP is 60 minutes. This summarizes some of the key information and questions contained in the document about pharmaceutical manufacturing equipment and processes.

Uploaded by

kavya nainita
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
3K views3 pages

PMT MCQ

The document discusses various topics related to pharmaceutical manufacturing technology including: 1) Equipment used for tablet coating includes standard coating pans, perforated pan systems, and fluidized bed dryers. 2) The perforated pan system options given are Dria-coater pan, Pellegrini pan, and hi-coater pan but not the Accela-cota system. 3) One of the options given for disintegration time for uncoated tablets in the IP is 60 minutes. This summarizes some of the key information and questions contained in the document about pharmaceutical manufacturing equipment and processes.

Uploaded by

kavya nainita
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 3

Pharmaceutical manufacturing technology

1) Equipment used for the tablet coating….

a) Standard coating pan b) perforated pan system c) fluidized bed dryer d) all the
above

2) Which of the following is not the perforated pan system…?


a) Dria – coater pan b) Pellegrini pan c) hi- coater pan d) accela – cota system
3) What is the disintegration time for uncoated tablets in IP is…?

a) 30 min b) 120 min c) 15 min d) 60 min

4) Immersion tube system comes under which type of equipment…

a) Standard coating pan b) perforated c) fluidized bed dryer d) spray dryer

5) What are bridging remedies…

a) Increase plasticizer contents or change in plasticizer concentration

b) Use optimum and efficient drying conditions

c) Decrease the drying air temperature

d) Decrease plasticizer concentration and increase molecular weight of plasticizer.

6)what is the input for production system?

a) energy b) materials c) men d) all the above

7) which is not included in the pre-compression evaluation parameters?

a) bulk density b) angle of repose c) tapped density d) FTIR studies

8) which of the following is not a quality control test for non-sterile products?

a) pyrogen test b) disintegration test c) dissolution test d) content uniformity test

9) which test is used for particle size determination?

a) sieving b) light scattering c) sedimentation rate d) all the above


10) the viscosity of ophthalmic preparations is in between?

a) 15-25 cp b) 20-25 cp c) 10-15 cp d) 19-25 cp

11) the % friability should be in the range of ?

a) 1-1.5 % b) 0.5-1% c) 1-2% d) 0.5-1.5%

12) elements of production planning includes ?

a) planning, routing b) scheduling, dispatching c) follow up, inspection d) all the


above

13) factors influencing plant layout ?

a) factory building b) nature of product c) production process d) all the above

14) acceptance limit for weight variation test for tablets 130 mg or less?

a) ±10% b) ±7.5% c) ±5 % d) ±2.5%

15) the temperature maintained for disintegration test apparatus

a) 37±2 0C b) 35±2 0C c) 37±0.5 0C d) 35±0.5 0C

16) what are the formulation related problems of tablets

a) double impression, capping

b) sticking, binding, picking

c) cracking, chipping, capping

d) none of the above

17) what is the remedy for erosion

a) control drying rate and temperature

b) reducing spray rate

c) increasing pan speed

d) all the above


18) examples of natural binders

a) ethyl cellulose, methyl cellulose

b) acacia, gelatin, cellulose

c) PEG, PVP

d) none of the above

19) due to improper mixing tablets and uneven spraying causes

a) blooming b) blushing c) color variation d) bridging

20) speed of slide blade (chopper) in RMG

a) slow b) fast c) medium d) none of the above

You might also like