The document provides installation instructions and specifications for three models of smart power savers: a single phase model (H), a three phase model (C), and a large three phase model (STC). It describes the key parameters of each model including power range, voltage, frequency, temperature range, dimensions, weight, savings percentage, warranty period and lifetime. Detailed step-by-step installation instructions are provided for each model explaining how to connect the power wires and current sensors and ensure proper operation.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
90 views7 pages
Jumbo Smart Saver User Manual HCSTC PDF
The document provides installation instructions and specifications for three models of smart power savers: a single phase model (H), a three phase model (C), and a large three phase model (STC). It describes the key parameters of each model including power range, voltage, frequency, temperature range, dimensions, weight, savings percentage, warranty period and lifetime. Detailed step-by-step installation instructions are provided for each model explaining how to connect the power wires and current sensors and ensure proper operation.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7
Smart Power Saver User’s Manual
Parameters
Single Phase Smart Power Saver H Model:
Power 5KW to 60KW Input One Phase(1P2W)
Voltage 90V-265V/Phase Frequency 50HZ/60HZ Working Temp(℃) -20~75 Size (W*L*H mm) 275x210x120 Weight (KG) 5-7KG Saving Percent 10%-30% Warranty 2 Years Life Time 10 Years IP Level IP43 Controlling Intelligent
Three Phase Smart Power Saver C Model:
Power 10KW to 100KW Input Three Phase(3P4W)
Voltage 155V-450V/Phase Frequency 50HZ/60HZ Working Temp(℃) -20~75 Size (W*L*H mm) 460x420x120 Weight (KG) 14-17KG Saving Percent 10%-30% Warranty 2 Years Life Time 10 Years IP Level IP43 Controlling Intelligent
Three Phase Smart Power Saver STC Model:
Power 120KW to 600KW Input Three Phase(3P3W)
Voltage 155V-450V/Phase Frequency 50HZ/60HZ Working Temp(℃) -20~75 Size (W*L*H mm) 400x400x150 Weight (KG) 15-20KG Saving Percent 10%-30% Warranty 2 Years Life Time 10 Years IP Level IP43 Controlling Intelligent Installation
Single Phase Smart Power Saver H Model:
Installation Introduction:
Installation is suggested to be handled by qualified technician. Supplier is free of responsibility due to
modify, open or repair the box by customers without the permission. 1.Please choose the right H saver model for installation. 2. H saver can be installed after the power meter for the whole system or be close to any 1P2W inductive load. A separated breaker B (32Amp) is suggested to be installed before H saver. 3. There are 4 wires from the H saver. Red is live phase “L”. Blue is neutral phase “N”. Green-Yellow is ground “G” . Black is CT(current sensor) wire. 4. Turn the main breaker “A”& branch breaker “B” off, connect the “L” & “N” phases after the breaker “B”, and “G” wire to earth. Insert the CT head tightly into the H saver CT socket. Don’t plug in or out the CT head when the H saver Switcher is ON,or you may damage the controller inside of H saver. 5. If all connection are right after double checking,turn the breaker “A” on to power loads. After 60 seconds, firstly,turn the breaker “B” on.Later,turn the switcher from the H saver on to power the H saver. 6. As long as the LCD screen shows data U/I/PF/S, then,hang CT connector on L phase to start the saving mode. U/I/PF/S data will be changed automatically according to the working status of H saver. Note: ①. U=System Voltage; I=System Current; PF=System Power Factor; S=System Amp Saving Rate. ②.LED 1=Power on/off;LED2 to LED 7=Working Mode of H Saver. LED1-LED7 from left to right. 7. If there isn’t load working in the system, please turn the breaker “B” off and the Switcher from H saver off. If there is loads working, please turn the breaker “B” on and then the Switcher from H saver on for saving. 8. If the LCD screen or all LED lights isn’t working, please contact the supplier for help.
Three Phase (3P4W) Smart Power Saver C Model:
Installation Introduction:
Installation is suggested to be handled by qualified technician. Supplier is free of responsibility due to
modify, open or repair the box by customers without the permission.
1. Please choose the right C saver model for installation.
2. C saver can be installed after the power meter for the whole system or be close to any 3P4W inductive load. A separated breaker B (≥32Amp) is suggested to be installed before C saver. 3. There are 8 wires from the C saver. Red is live phase “L1”&”L2”&”L3”. Blue is neutral phase “N”. Green-Yellow is ground “G” . 3 Black wires are CT wires: CT for BN=The current sensor for the brown wire phase of C saver; CT for BK=The current sensor for the black wire phase of C saver; CT for GY=The current sensor for the gray wire phase of C saver; 4. Turn the main breaker “A”& branch breaker “B” off, connect the “L1”&”L2”&”L3” & “N” phases after the breaker “B”, and “G” wire to earth. Insert the CT heads tightly into the C saver CT sockets. Don’t plug in or out the CT heads when the C saver Switcher is ON,or you may damage the controller inside of C saver. 5. If all connection are right after double checking,turn the breaker “A” on to power loads. After 60 seconds, firstly,turn the breaker “B” on.Later,turn the switcher from the C saver on to power the C saver. 6. As long as all of the LCD screens shows data U/I/PF/S, then,hang CT connectors on “L1”&”L2”&”L3” phase to start the saving mode. U/I/PF/S data will be changed automatically according to the working status of C saver. Note: ①. U=System Voltage; I=System Current; PF=System Power Factor; S=System Amp Saving Rate. ②.LED 1=Power on/off;LED2 to LED 7=Working Mode of C Saver;LED1-LED7 from left to right. 7. If there isn’t load working in the system, please turn the breaker “B” off and the Switcher from C saver off. If there is loads working, please turn the breaker “B” on and then the Switcher from C saver on for saving. 8. If any LCD screen or all LED lights from any phase isn’t working, please contact the supplier for help. Three Phase (3P3W) Smart Power Saver STC Model: Installation Introduction:
Installation is suggested to be handled by qualified technician. Supplier is free of responsibility due to
modify, open or repair the box by customers without the permission.
1. Please choose the right STC saver model for installation.
2. STC saver can be installed after the power meter for the whole system or be close to any 3P3W inductive load. A separated breaker B (≥60Amp) is suggested to be installed before STC saver. 3. There are 5 wires from the STC saver. Red is live phase “L1”&”L2”&”L3”. Black wire is CT wire.Another black wire with arrow is the wire for GSM antenna. If customer specially needs for remote controlling by GSM system, we will add this function. 4. Turn the main breaker “A”& branch breaker “B” off, connect the “L1”&”L2”&”L3” phases after the breaker “B”. Insert the CT head tightly into the STC saver CT socket. Don’t plug in or out the CT head when the STC saver Switcher is ON,or you may damage the controller inside of STC saver. 5. If all connection are right after double checking, turn the breaker “A” on to power loads. After 60 seconds, firstly, turn the breaker “B” on. Later,turn the switcher from the STC saver on to power the STC saver. 6. As long as the LCD screen shows data U/I, then, find out the biggest current live phase by current clamp meter from “L1”&”L2”&”L3”,and hang the CT connector on that phase to start the saving mode. U/I data will be changed automatically according to the working status of STC saver. Note: ①. U=System Voltage; I=System Current. ②.LED Indicator=STC saver on/off working mode. 7. If there isn’t load working in the system, please turn the breaker “B” off and the Switcher from STC saver off. If there is loads working, please turn the breaker “B” on and then the Switcher from STC saver on for saving. 8. If the LCD screen or the LED indicator from STC saver isn’t working, please contact the supplier for help. Warranty Card