BOQDoc 2273
BOQDoc 2273
Amount in
Sl. No. Description of item Unit Quantity Rate in Rs.
Rs.
6.3 Extra for RCC all grades above 20.00 metre height up to
and including 32.00 metre height from Plinth level. Cu.M 50
7.1 Using TMT Bars of Specified Grades of all sizes. TMT bars
to be supplied by the contractor from the own plants of
SAIL,RINL or TATA make only using virgin materials. MT 2,190
8.3 Left -in shuttering: design, supply, place formwork for left-
in shuttering, using metal deck sheets as formwork inclusive
of all materials, labour, studs, fastners, tools and plants, two
coats of approved primer or bottom surface, retrievable
supporting materials etc. complete as per specification,
drawings and as directed by the Engineer. The non- Sqm 6
retrievable structural steel required to be provided for
supporting the left-in shutter shall be measured and paid in
relevant structural steel item.
Flooring
Waterproofing
Painting
28.1 Providing and fixing C.P. brass wall mixer with provision
for over head shower complete with 115mm long bend pipe
on upper side, connecting legs and flanges CON -
273KNUPR (Jaquar CONTINENTAL series) or equivalent Each set 8
quality of GROHE/KOHLER as approved.
28.3 Providing and fixing C.P Brass towel rail 600mm long of
approved make complete fixed to walls with 30mm CP
brass screws with concealed fitting arrangement all as Each 19
directed by the Engineer-in-Charge.
31.1 Supplying of Cast iron man hole cover or Cast iron Steps
of approved make and weight as specified in the drawings
Kgs. 700
or as directed by the Engineer-in-charge.
Note:
1. Tests as per IS:3614 Part-II standards for 1 hour fire
rating for full size door with vision panel and all fittings
and fixtures shall be conducted at approved laboratory
for 3 nos. of doors. One door shall be tested from the
first lot before shipment to site and remaining at
random from balance supply. No separate payment
shall be made for the testing including the door sample.
Fixtures given separately such as heavy duty door
closers shall be paid under the relevant item. Area
covered by outer surface of the door frame shall be
considered for the measurement under this item.
2. Payment @ 70 % shall be made against this item on
supply and acceptance of doors at site & balance 30 %
payment shall be made after successful installation of
doors with all fittings & fixtures, painting etc.
37.3 All other EPs not covered above like plate, hatch frame,
edge angle, floor drain etc. MT 1
39.1.1 10 mm dia
EACH 10
39.1.2 12 mm dia
EACH 10
39.1.3 16 mm dia
EACH 10
39.2.1 10 mm dia
EACH 10
39.2.2 12 mm dia
EACH 10
39.2.3 16 mm dia
EACH 10
39.2.4 20 mm dia
EACH 10
39.2.5 25 mm dia
EACH 10
41.2 Mix 1:2 cement sand grout with approved anti shrinkage
compound Cum 2
41.3 Mix 1:1:2 grout with cement, sand and 6 mm down stone
chips with approved anti-shrinkage compound Cum 2
41.4 Mix 1:2.5 cement sand Dry pack mix with approved anti-
shrink compound Cum 2
44.6 SS, 100 NB, blind flange conforming to ASTM 182 F 304L
Nos 3
44.7 SS, 150 X 100 NB concentric re3ducer, BW end, sch.40,
conforming to ASTM A 403 Typ 304L Nos 15
47.1 0 M to 50 M
RM 300
48 FIELD TESTS
49.4 Tensile test by Point load method as per IS 8764 with the
samples in saturated condition. Nos 25
1.2 Supply and Execution of Exothermic welding for T-Joint Nos 220
suitable for 95 Sq.mm stranded copper conductor
1.3 Supply and Execution of Exothermic welding for X-Joint Nos 162
suitable for 95 Sq.mm stranded copper conductor
4.1 Supply and installation of cast copper alloy 70mmX70mm, 4 Nos 126
mm thick wall / floor / column pads (with 4 tapped holes for
10mm bolts along with the bolts) flushing its face fully with
wall / floor surface. (Refer for details of earth pads &
brazing at Section VI)
4.2 Supply and Execution of brazing to connect 65.09 Sq.mm Nos 126
stranded copper conductor with cast copper alloy
70mmX70mm, 4 mm thick wall / floor / column pads (Refer
for details of earth pads & brazing at Section VI)
4.3 Supply and Execution of brazing to connect 65.09 Sq.mm Nos 126
stranded copper conductor (from earth pad) with running
65.09 sqmm. Copper conductor in the embeded concrete
(Refer for details of earth pads & brazing at Section VI)
5.2 Supply & installation of 3 mm thick Saddle & 3 mm thick Set 575
spacer with 2 nos. of 10 mm dia and 50mm long GS bolt,
nut and washer (for each saddle space set) to fix 35 mm x 6
mm GS strip on columns, walls and roof slab.
5.3 Supply & installation of Test links complete with all Nos 16
accessories at a height of 1 mtr. From ground and
connection to main earthing system ground rod.
5.7 Supply & installation of concrete pedestral on roof top of Nos 100
dimensions 250mm X 250mm X 200mm for support &
installation of GS strip conductor (35 mm x 6 mm).
Note : - 1. Certified that the details as furnished above are true to the best of my / our knowledge and records. I/We give under taking that if at any stage of
scrutiny of tender or currency of this contract, any information submitted by me/us is/are found incorrect, the corporation shall have the right to reject the
bid/terminate the contract at its discretion and I/We shall have no claim for any compensation whatsoever thereof.
2. All the terms and conditions of NPCIL’s laid in the tender documents are acceptable to us and we have not made any deviations from the same or put forward
any additional conditions in our offer.
3. Quoted amount shall be inclusive of all statutory liabilities, taxes including GST, cess, duties, levies etc