Dataman 50: Quick Reference Guide
Dataman 50: Quick Reference Guide
2019 February 01
Revision: 6.1.6.13
Precautions
To reduce the risk of injury or equipment damage, observe the following precautions
when you install the Cognex product:
l Route cables and wires away from high-current wiring or high-voltage
power sources to reduce the risk of damage or malfunction from the
following causes: over-voltage, line noise, electrostatic discharge (ESD),
power surges, or other irregularities in the power supply.
l Changes or modifications not expressly approved by the party responsible
for regulatory compliance could void the user’s authority to operate the
equipment.
l Ensure that the cable bend radius begins at least six inches from the
connector. Cable shielding can be degraded or cables can be damaged or
wear out faster if a service loop or bend radius is tighter than 10X the cable
diameter.
l This device should be used in accordance with the instructions in this
manual.
l All specifications are for reference purposes only and can change without
notice.
2
Product Overview
1 Status LEDs:
- YELLOW
- GREEN
- RED
2 Cable
3 Internal illumination
4 3-position M12 lens
5 LED aimer
6 Mounting holes (M3 x 3.5 mm)
3
DataMan 50 Accessories
CABLES
USB Cable, 1.5 m (DM100-USB-000),
USB Cable, 3 m (DM100-USB-030)
USB and Flying Leads I/O Cable, 2.0 m (DM-USBIO-00)
LENS COVERS
Clear Front Cover (DM-50-CLCOV)
ESD-safe Front Cover (DM50-CLCOV-ESD)
OTHER
Power Supply, 6 V (DM100-PWR-000)
4
Dimensions
5
Field of View and Reading Distances
6
Connecting the Reader
7
Installation
Installation procedures and specifications are presented in detail in the DataMan® 50
Reference Manual, which is installed with the DataMan Setup Tool. From the
Windows Start menu, select the following to access the manual: All Programs >
Cognex > DataMan Software vx.x.x > Documentation.
Note:
l Cables are sold separately.
l If a standard component is missing or damaged, immediately contact
your Cognex Authorized Service Provider (ASP) or Cognex
Technical Support.
CAUTION: All cable connectors are keyed to fit the connectors on the reader.
Do not force the connections or damage may occur.
Mounting
Mounting the DataMan reader at a slight angle (15°) can reduce reflections and
improve performance.
Use the set of mounting holes on the rear part to mount the DataMan reader.
8
Connect the Breakout Cable
Note: You can clip unused wires short or use a tie made of non-conductive
material to tie them back. For RS-232, use the Power Supply return path for
ground.
1. Verify that the power supply being used is unplugged and not receiving
power.
2. Connect the cable on the back of the device to either a USB adapter cable
with power tab or to an RS-232 adapter cable with power tab.
3. Connect a 6 V power supply.
4. Restore power to the power supply and turn it on if necessary.
9
Install Software and Documentation and
Connect the Reader
Follow the steps below to connect your reader to power and network:
1. Connect the USB or RS-232 cable to your reader.
2. Connect the cable to a power supply.
To configure a DataMan 50 reader, the DataMan Setup Tool software must be
installed on a networked PC. The DataMan Setup Tool is available from the
DataMan support site: http://www.cognex.com/support/dataman.
1. After installing the software, connect the DataMan 50 reader to your PC.
2. Launch the DataMan Setup Tool and click Refresh.
3. Select your DataMan 50 reader from the list and click Connect.
10
DataMan 50 Specifications
Weight 76 g (including cable)
Operating 0 ºC — 40 ºC (32 ºF — 104 ºF)
Temperature
Storage Temperature -10 ºC — 60 ºC (-14 ºF — 140 ºF)
Maximum Humidity 95% (non-condensing)
Environmental IP65 if sealing is installed properly
Vibration EN61373 including IEC 60068-2-6,60068-2-64 6.4, and 60068-2-27
LED Safety IEC 62471: Exempt risk group, no further labeling is required.
Codes 1-D barcodes: Codabar, Code 39, Code 128, and Code 93, Interleaved 2 of 5, Pharma, GS1
DataBar, Postal, UPC/EAN/JAN
2-D barcodes: Data Matrix™
QR Code and microQR Code, MaxiCode, RSS/CS, PDF 417, MicroPDF 417
Discrete I/O Output 0,1 IMAX @ 24 VDC 25 mA
Operating Limits
VMAX 26 V
Output 2 Source VTYP 4V
Sink VIH 4 V - VPSU
VIL 0—2V
Input 0 (Trigger) VIH 4 — 26 V
Input 1
VIL 0—2V
ITYP 3 mA
Power Supply VPSU 4,5 — 26 VDC
Requirements
2.5 W maximum
LPS or NEC class 2 power supply
11
DataMan 50 Imager Specifications
Specification DataMan 50 Series Imager
Image Sensor 1/3 inch CMOS
Image Sensor Properties 4.51 mm x 2.88 mm (H x V), 6.0 µm square pixels
Image Resolution (pixels) 752 x 480
Electronic Shutter Speed 18 µs to 25 ms exposure
Image Acquisition up to 60 fps at full resolution
Lens Type 6.2 mm, F:5,3 focal position M12 lens with IR blocking filter
LED Wavelengths
The following table shows LED types and the related wavelengths:
LED λ [nm]
RED 617
12
Compliance Statements
DataMan 50 readers meet or exceed the requirements of all applicable standards
organizations for safe operation. However, as with any electrical equipment, the best
way to ensure safe operation is to operate them according to the agency guidelines
that follow. Please read these guidelines carefully before using your device.
Regulator Specification
USA FCC Part 15, Subpart B, Class A
Canada ICES-003, Class A
European Community EN55022, Class A
EN55024
13
Safety and Regulatory
Canadian Compliance This Class A digital apparatus complies with Canadian ICES-003. Cet appareil
numérique de la classe A est conforme à la norme NMB-003 du Canada.
C-Tick Statement Conforms to AS/NZS CISPR 22/ EN 55022 for Class A Equipment.
14
The crossed out wheeled bin symbol informs you that the product should not
be disposed of along with municipal waste and invites you to use the appropriate
separate take-back systems for product disposal.
If you need more information on the collection, reuse, and recycling systems, please
contact your local or regional waste administration.
You may also contact your supplier for more information on the environmental
performance of this product.
15
China RoHS
Hazardous Substances 有 害 物 质
Part Name Lead (Pb) Mercury Cadmium Hexavalent Polybrominated Polybrominated
部件名称 铅 (Hg) (Cd) Chromium biphenyls (PBB) diphenyl ethers
汞 镉 (Cr (VI)) 多溴联苯 (PBDE)
六价铬 多溴二苯醚
DM50 X O O O O O
This table is prepared in accordance with the provisions of SJ/T 11364.
这 个 标 签 是 根 据 SJ / T 11364 的 规 定 准 备 的 。
O: Indicates that said hazardous substance contained in all of the homogeneous materials for this part is below the
limit requirement of GB / T26572 - 2011.
表 示 本 部 件 所 有 均 质 材 料 中 含 有 的 有 害 物 质 低 于 GB / T26572 - 2011 的 限 量 要 求 。
X: Indicates that said hazardous substance contained in at least one of the homogeneous materials used for this
part is above the limit requirement of GB / T26572 - 2011.
表 示 用 于 本 部 件 的 至 少 一 种 均 质 材 料 中 所 含 的 危 害 物 质 超 过 GB / T26572 - 2011 的 限 制 要 求 。
16
Copyright © 2019
Cognex Corporation. All Rights Reserved.