Eaves & Gutter Section Detail: Office of The President Municipality of Tigaon

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

0.50 THK. PRE-FINISHED 0.50 THK.

PRE-FINISHED
RIB-TYPE G.I. SHEET ROOFING RIB-TYPE G.I. SHEET ROOFING

150mm. x 65mm. x 20mm. / J-BOLT @ TOP


6mm. O
6mm. O J-BOLT @ TOP x 2.00mm. THK. LIP CHANNEL AND BOTTOM PURLINS ;
AND BOTTOM PURLINS ; PURLINS @ 700mm. O.C. WITH / TEK SCREW @
5mm. O
5mm. O TEK SCREW @ 12mm. SAGROD @ MIDSPAN THE REST OF THE PURLINS
THE REST OF THE PURLINS
0.70
150mm. x 200mm. PVC
GUTTER ON INTERNAL
0.03 150mm. x 65mm. x 20mm.
x 2.00mm. THK. LIP CHANNEL
100mm. x 50mm. x 3mm. PURLINS @ 700mm. O.C. WITH
BRACKETS THICK CLEATS 12mm. SAGROD @ MIDSPAN
0.70

0.03
75mm. x 75mm. x 6mm. THK.

0.20
ANGLE BAR SEAT, ANCHORED

0.30
TO INCLINED BEAM WITH 75mm. x 75mm. x 6mm. THK.
2-12mm. O/ ANCHOR BOLTS ANGLE BAR SEAT, ANCHORED
TO INCLINED BEAM WITH
A B 2-12mm. O/ ANCHOR BOLTS
4.00
1.925 2.075 0.50mm. THICK
LINE OF INCLINED BEAM
PRE-FIN. G.I. FASCIA
100mm. x 50mm. x 3mm.
0.70 1.375 0.15 0.40 THICK CLEATS
REINFORCED CONCRETE
0.30 0.40 150mm. x 200mm. 6mm. THK. FIBER CEMENT BEAM
PVC GUTTER ON BOARD ON 19mm. x 50mm.
x 0.40mm. THK. METAL INCLINED BEAM
INTERNAL BRACKET
FURRING @ 600mm. O.C.
FIREWALL 2 EAVES & GUTTER SECTION DETAIL / TOP AND
16mm. O
BOTTOM BARS
S-4 SCALE : 1 : 10 MTS.
150mm. x 200mm.
PVC GUTTER ON / STIRRUPS
10mm. O
2.00

50mm. x 50mm. x 3.0mm. THK.


ANGLE BAR RAFTERS, ANCHORED 150mm. THK. CHB
FIREWALL PLAIN CEMENT
5 INCLINED BEAM SECTION DETAIL
0.40 0.30

TO FIREWALL BY 2-12mm. O
PLASTERED FINISH 0.40 0.40 S-4 SCALE : 1 : 10 MTS.
ANCHOR BOLTS
0.70

/ J-BOLT @ TOP
6mm. O
AND BOTTOM PURLINS ;
3 B-2
/ TEK SCREW @
5mm. O
THE REST OF THE PURLINS
0.50mm. THK. PRE-FINISHED
G.I. FLASHING 0.50 THK. PRE-FINISHED
150mm. x 65mm. x 20mm. x 2.0mm. G.I. RIDGE ROLL
LIP CHANNEL PURLINS SPACED
@ 700mm. O.C. WITH 12mm. O 150mm. x 65mm. x 20mm.
SAGROD @ MIDSPAN x 2.00mm. THK. LIP CHANNEL
PURLINS @ 700mm. O.C. WITH / J-BOLT @ TOP
6mm. O
12mm. SAGROD @ MIDSPAN AND BOTTOM PURLINS ;
/ TEK SCREW @
5mm. O
THE REST OF THE PURLINS
0.30
3.25

0.30
IB - 1

IB - 1

0.50mm. THK. PRE-FINISHED 0.50 THK. PRE-FINISHED


RIB-TYPE G.I. SHT. ROOFING RIB-TYPE G.I. SHEET ROOFING

150mm. x 65mm. x 20mm.


x 2.00mm. THK. LIP CHANNEL
75mm. x 75mm. x 6.0mm. THK. 75mm. x 75mm. x 6mm. THK. PURLINS @ 700mm. O.C. WITH
ANGLE BAR SEAT, ANCHORED ANGLE BAR SEAT, ANCHORED 12mm. SAGROD @ MIDSPAN
TO INCLINED BEAM WITH LINE OF 100mm. x 50mm. x 3mm. TO INCLINED BEAM WITH
THK. CLEATS BEHIND PURLINS / ANCHOR BOLTS
6.50

2-12mm. O ANCHOR BOLTS 2-12mm. O


2
75mm. x 75mm. x 6mm. THK.
ANGLE BAR SEAT, ANCHORED
12mm. O ANCHOR BOLT TO INCLINED BEAM WITH
2-12mm. O/ ANCHOR BOLTS

0.50mm. THK. PRE-PAINTED


RIB-TYPE G.I. SHEET ROOFING
INCLINED BEAM 100mm. x 50mm. x 3mm.
IB - 1

IB - 1

RIDGE ROLL
3.25

THICK CLEATS

6 SECTION DETAIL
S-4 SCALE : 1 : 10 MTS.
150mm. x 200mm.
PVC GUTTER ON
PURLIN CONNECTION
B-2
3 SECTION DETAIL 0.50mm. THICK
1 SCALE : 1 : 10 MTS. PRE-PAINTED RIB
0.30 0.40

S-4 SHEET FLASHING


0.70

0.50mm. THICK PRE-PAINTED


RIB G.I. SHEET ROOFING

0.30
0.30 0.30 FIREWALL

TOP OF ROOF BEAM 0.50mm. THICK


0.05
PRE-PAINTED RIB 0.05
1 ROOF FRAMING PLAN SHEET FLASHING

S-4 SCALE : 1 : 50 MTS.


0.30

0.50mm. THICK PRE-PAINTED


RIB G.I. SHEET ROOFING

150mm. x 200mm.
PVC GUTTER ON
INTERNAL BRACKET

0.15

0.15
0.50mm. THICK PRE-PAINTED
G.I. SHEET FLASHING

4 FLASHING SECTION DETAIL 7 INSIDE GUTTER SECTION DETAIL


S-4 SCALE : 1 : 10 MTS. S-4 SCALE : 1 : 10 MTS.

PROJECT TITLE : Republic of the Philippines ARCHITECT / ENGINEER DESIGNED: HTTRD CHECKED: RGRAMOS SHEET NO.
MUNICIPALITY OF TIGAON Office of the President
Province of Camarines Sur DRAWN: PLIBARDALOZA DATE:
NATIONAL HOUSING AUTHORITY
CHECKED BY RECOMMENDING APPROVAL SHEET CONTENT

REVIEWED BY S-4
TIGAON RESETTLEMENT PROJECT P1 ROOFING DETAILS

DESIGNATION
APPROVED BY REVISIONS DATE:

LOCATION : Engr. CRISTINA A. CABANGON Engr. ALBERT A. PERFECTO MARCELINO P. ESCALADA JR. 9 12
REG No.: DATE:
BRGY. SALVACION, TIGAON, CAMARINES SUR DISTRICT MNGR DISTRICT II - REGION V REGIONAL MANAGER REGION V GENERAL MANAGER, NHA
MUNICIPAL MAYOR PTR No.: PLACE: