95 04 CR4.de - en
95 04 CR4.de - en
95 04 CR4.de - en
Product description
Document No .: 211185.95.04
1. Generally
The electronic assembly is installed as an additional device in a vehicle, and helps increase the performance of the engine. The connection to
the vehicle via a vehicle-specific cable set.
A microcontroller determines from the measured values of the rail pressure actual value, and coolant temperature (option), the characteristic
curve and the criterion for the use of the increase in output and outputs the result as modified rail pressure feedback signal further to the
control unit of the vehicle. The function of the control unit of the diesel injection system is not affected by the additional electronics.
ワ About a programming various parameters of the additional electronics can be changed to adapt it to the vehicle-specific values.
Two differently colored light emitting diodes indicate the operating state of the device and also serve for fault detection.
boxtuning GmbH | Reusch Road 54 | 73092 Heiningen | Phone 07161 / 4032-0 | Fax 07161 / 4032-21
Page 2 v. 6
Product description: Document No .:
(CR4)
inputs:
RD1i - Rail pressure actual value 1 Measuring range: 0 ... 5.0V
RD2i - Rail pressure actual value 2 Measuring range: 0 ... 5.0V
Tin - Coolant temperature (optional additional function) Measuring range: 0 ... 5.0V
outputs:
RD1o - rail pressure 1 Voltage range: 0 ... 5.0V
RD12 - rail pressure 2 Voltage range: 0 ... 5.0V
programming
The operating status is indicated by two LED (green + red) displays operating status
boxtuning GmbH | Reusch Road 54 | 73092 Heiningen | Phone 07161 / 4032-0 | Fax 07161 / 4032-21
Page 3 v. 6
Product description: Document No .:
(CR4)
4th parameter
boxtuning GmbH | Reusch Road 54 | 73092 Heiningen | Phone 07161 / 4032-0 | Fax 07161 / 4032-21
Page 4 v. 6
Product description: Document No .:
(CR4)
is a 3-row plug connector for plugging of jumpers (jumper) under the removable cover on the back of the device.
The programmed values of parameter 3 (Rof) and parameter 4 (RE) can be changed respectively in 4 steps in minus and plus
direction hereby.
To make a correction parameter, the jumper is placed vertically, so there? a pin of an externa
゚ older and middle pins row are connected with each other.
-8th -6 -4 -2 0 + 2 +4 +6 +8
Parameter 8 (JP), the correction facility can be disabled via jumpers or activated.
Watch out: An activated jumper must be put on a position!
The rail pressure is changed if the following conditions are met: RDi> Son AND Ron <RDi <Rof AND Tin <Sound (only
with temperature measurement)
boxtuning GmbH | Reusch Road 54 | 73092 Heiningen | Phone 07161 / 4032-0 | Fax 07161 / 4032-21
Page 5 v. 6
Product description: Document No .:
(CR4)
Connect 5.1 programmer via suitable cable (CR) with the tuning box
The four keys below the display have the following functions:
boxtuning GmbH | Reusch Road 54 | 73092 Heiningen | Phone 07161 / 4032-0 | Fax 07161 / 4032-21
Page 6 v. 6
Product description: Document No .:
(CR4)
6th Table of values for accelerator pedal position and rail pressure and temperature
Param
value reading
in volt Paramvalue reading
in volt Paramvalue reading
in volt Paramvalue reading
in volt Paramvalue reading
in volt
0 0.00 51 1.00 102 2.00 153 3.00 204 4.00
1 0.02 52 1.02 103 2.02 154 3.02 205 4.02
2 0.04 53 1.04 104 2.04 155 3.04 206 4.04
3 0.06 54 1.06 105 2.06 156 3.06 207 4.06
4 0.08 55 1.08 106 2.08 157 3.08 208 4.08
5 0.10 56 1.10 107 2.10 158 3.10 209 4.10
6 0.12 57 1.12 108 2.12 159 3.12 210 4.12
7 0.14 58 1.14 109 2.14 160 3.14 211 4.14
8th 0.16 59 1.16 110 2.16 161 3.16 212 4.16
9 0.18 60 1.18 111 2.18 162 3.18 213 4.18
10 0.20 61 1.20 112 2.20 163 3.20 214 4.20
11 0.22 62 1.22 113 2.22 164 3.22 215 4.22
12 0.24 63 1.24 114 2.24 165 3.24 216 4.24
13 0.25 64 1.25 115 2.25 166 3.25 217 4.25
14 0.27 65 1.27 116 2.27 167 3.27 218 4.27
15 0.29 66 1.29 117 2.29 168 3.29 219 4.29
16 0.31 67 1.31 118 2.31 169 3.31 220 4.31
17 0.33 68 1.33 119 2.33 170 3.33 221 4.33
18 0.35 69 1.35 120 2.35 171 3.35 222 4.35
19 0.37 70 1.37 121 2.37 172 3.37 223 4.37
20 0.39 71 1.39 122 2.39 173 3.39 224 4.39
21 0.41 72 1.41 123 2.41 174 3.41 225 4.41
22 0.43 73 1.43 124 2.43 175 3.43 226 4.43
23 0.45 74 1.45 125 2.45 176 3.45 227 4.45
24 0.47 75 1.47 126 2.47 177 3.47 228 4.47
25 0.49 76 1.49 127 2.49 178 3.49 229 4.49
26 0.51 77 1.51 128 2.51 179 3.51 230 4.51
27 0.53 78 1.53 129 2.53 180 3.53 231 4.53
28 0.55 79 1.55 130 2.55 181 3.55 232 4.55
29 0.57 80 1.57 131 2.57 182 3.57 233 4.57
30 0.59 81 1.59 132 2.59 183 3.59 234 4.59
31 0.61 82 1.61 133 2.61 184 3.61 235 4.61
32 0.63 83 1.63 134 2.63 185 3.63 236 4.63
33 0.65 84 1.65 135 2.65 186 3.65 237 4.65
34 0.67 85 1.67 136 2.67 187 3.67 238 4.67
35 0.69 86 1.69 137 2.69 188 3.69 239 4.69
36 0.71 87 1.71 138 2.71 189 3.71 240 4.71
37 0.73 88 1.73 139 2.73 190 3.73 241 4.73
38 0.75 89 1.75 140 2.75 191 3.75 242 4.75
39 0.76 90 1.76 141 2.76 192 3.76 243 4.76
40 0.78 91 1.78 142 2.78 193 3.78 244 4.78
41 0.80 92 1.80 143 2.80 194 3.80 245 4.80
42 0.82 93 1.82 144 2.82 195 3.82 246 4.82
43 0.84 94 1.84 145 2.84 196 3.84 247 4.84
44 0.86 95 1.86 146 2.86 197 3.86 248 4.86
45 0.88 96 1.88 147 2.88 198 3.88 249 4.88
46 0.90 97 1.90 148 2.90 199 3.90 250 4.90
47 0.92 98 1.92 149 2.92 200 3.92 251 4.92
48 0.94 99 1.94 150 2.94 201 3.94 252 4.94
49 0.96 100 1.96 151 2.96 202 3.96 253 4.96
50 0.98 101 1.98 152 2.98 203 3.98 254 4.98
255 5.00
boxtuning GmbH | Reusch Road 54 | 73092 Heiningen | Phone 07161 / 4032-0 | Fax 07161 / 4032-21