Etalko-Technical Data Universal Dimmer Switches Capacity Enhancer and 1-10V Controllers
Etalko-Technical Data Universal Dimmer Switches Capacity Enhancer and 1-10V Controllers
Etalko-Technical Data Universal Dimmer Switches Capacity Enhancer and 1-10V Controllers
up to 400 W up to 300 W
up to 400 W
Capacative transformers (C) 3)8) − EUD12DK: up to up to 300 W − − − DTD65L/FL and
EUD61NPL: 200W
800W DTD55L: up to 200 W
up to 400 W up to 400 W up to 300 W
Dimmable energy saving lamps
− EUD12DK: up to EUD61NPL: 200 W up to 300 W − − − DTD65L/FL and
ESL 5)6)9)
800 W (not EUD61NP) DTD55L: up to 200 W
up to 400 W up to 400 W up to 300 W
Dimmable 230 V LED
− EUD12DK: up to EUD61NPL: 200 W − − − − DTD65L/FL and
lamps 5)6)9)
800 W (not EUD61NP) DTD55L: up to 200 W
Dimmable LED lamps ELD61:4A
− − − − − − −
12-36 V DC KLD61:30 W
40 mA 40 mA
1-10 V EVG* − − − − − −
600 VA 600 VA
2 2 2 2
Maximum conductor cross- 6 mm 6 mm 6 mm 6 mm
4 mm 2 4 mm 2 4 mm 2 4 mm 2
section (3-fold terminal) (4 mm 2) (4 mm 2) (4 mm 2) (4 mm 2)
Two conductors of same 2.5mm 2 2.5 mm 2 2.5 mm 2 2,5 mm 2
1.5 mm2 1.5 mm2 1.5 mm2 1.5 mm2
crosssection (3-fold terminal) (1.5mm 2) (1.5 mm 2) (1.5 mm 2) (1.5 mm 2)
slotted/crosshead, slotted/crosshead, slotted/crosshead, slotted/cross- slotted/cross- slotted/cross- slotted/cross- slotted/cross-
Screw head
pozidriv pozidriv pozidriv head, pozidriv head, pozidriv head, pozidriv head, pozidriv head, pozidriv
Type of enclosure/terminals IP30/IP20 IP50/IP20 IP30/IP20 IP50/IP20 IP50/IP20 IP30/IP20 IP50/IP20 IP50/IP20
* EVG = electronic ballast units; KVG = conventional ballast units a) Secondary cable length with a maximum of 2 m. 1) At a load of more than 200 W (EUD12DK:400 W, EUD12F: 100 W) a ventilation clearance of 1/2 module
to adjacent devices must be maintained. The switching capacity of the EUD61 and DTD depends also on the ventilation conditions. 2) Per dimmer or capacity enhancer it is only allowed to use max. 2 inductive (wound)
transformers of the same type, furthermore no-load operation on the secondary part is not permitted. The dimmer might be destroyed. Therefore do not permit load breaking on the secondary part. Operation in
parallel of inductive (wound) and capacative (electronic) transformers is not permitted! 3) When calculating the load a loss of 20% for inductive (wound) transformers and a loss of 5% for capacitive (electronic)
transformers must be considered in addition to the lamp load. 4) Affects the max. switching capacity. 5) In the settings ESL and LED no wound (inductive) transformer must be dimmed. 6) Increase of capacity for
dimmable energy saving lamps ESL and dimmable 230 V LED lamps see page 9-8. 7) Only 1 fan motor may be connected. 8) For 12 V halogen and LED lamps. 9) Usually applies for dimmable energy saving lamps and
dimmable 230 V LED lamps. Different lamp electronics may result in restricted dimming areas, on/off problems and a limited maximum number of lamps (to 10 units), especially if the connected load is very low (e.g.
with 5 W LEDs). The comfort positions of the dimmer switches optimize the dimming range, which, however, only gives a maximum power up to 100 W. No inductive (wound) transformers may be dimmed in these
comfort positions.
To comply with DIN VDE 0100-443 and DIN VDE 0100-534, a Type 2 or Type 3 surge protection device (SPD) must be installed.