June 1996
This standard was approved by Working Committee 1-3 "Supporting Elements" of the Standards Committee for
Chemical Apparatus Construction(FNCA).
Changes
The following changes have been made with respect to DIN 28082-2: 1978-05:
a) Title changed
b) Standard designation added.
c) Change maximum screw forces.
d) Reference to proof of strength according to AD MerkbIan S 3/1 added.
e) Content editorially revised.
Previous issues
DIN 28082-2: 1977-06, 1978-05
Continued on pages 2 to 5
Standards Committee for Chemical Apparatus Construction (FNCA) in the DIN German Institute
for Standardization eV
@ DIN Deutsches Institut für Normung eV 'Any kind of reproduction, even in extracts, is only Ret. No. DIN 28082-2: 1996-06
permitted with the approval of the DIN Deutsches Institut für Normung e.?, Berlin.
Price gr. 07 Gerti: -He. 000z
Sole selling \ the number one by oe »tn Verlag GmbH. Joyyz Berlin
Page 2
DIN 28082-2: 1996-06
3rd execution
General tolerances according to DIN 28007-1 and DIN 8570 - D. Dimensions in millimeters
BB
t0
AA
1
) Dimensions to be swept b1. b2. d1 d5. h1 h2, s1 s3 and s6
Page 3
DIN 28082-2: 1996-06
To picture 1
1 Stand frame with foot ring and claws (version P) or double ring with bars (version D).
2 Fire protection insulation by arrangement.
3 Crampon; by agreement for frames with h2> 2,000 mm.
4 Ventilation holes; up to a nominal diameter of 1,000 mm at least 2 pieces, diameter 60 mm, from a nominal diameter
of 1100 mm at least 4 pieces, diameter 100 mm. The ventilation holes must be placed as high as possiblebe.
5 Purge holes; 2 pieces opposite. Only effective if the upper edge of the inner foundation part is equal to the
upper edge of the foot ring.
Inspection opening (or passage)
For d1 <1000 mm: size by arrangement.
For d1 ≥ 1 000 mm: minimum width 600
mm
Height 1 200 mm.
If possible, arrange between the anchor bolts; do not use as pipe penetration.
7 Passage for pipes
4 designation
Designation of a stand frame with anchor bolt M36, double ring version with bars (D) with anchor slot (S):
Stand frame DIN 28082 - M36 - D - S
Version D
double ring with Version P foot
webs ring and burst
20th
d
2nd
) One hole for attaching lightning protection earthing up to nominal diameter 1000 mm, two diametrically opposite
holes above.
Anchor slot or hole set axially free and arranged symmetrically to the main axis.
Figure 3: Version S with anchor slot and Version L with anchor hole
If the clear distance between the anchor claws is less than 1.5 times the plate width (I), a closed ring (double ring)
should be used here for design reasons.
Screw
kN
thread
10038 ') 10570')
M24 80 60 28 32 60 120 180 45 35.4 53.1
12th
M30 95 75 35 40 70 120 190 55 300 35 25t 56.6 84.9
h
M36 110 85 42 48 80 160 220 65 82.8 124.2
The values for the maximum tensile force of the anchor screw Fmax in Table 1 were determined with the yield
strengths fy, b, K at 20 ° C, a safety factor S = 2.2 and the core cross-section according to DIN 13-28.
Site5
DIN 28082-2: 1996-06
Screw thread
Material number
according to DIN up to M36 larger than M36
EN 10025 N / mm2 N / mm2
1.0038 240 215
1.0570 360
') For higher temperatures, the characteristic values specified for these materials in
AD-Merkblatt W13 apply.
6 Materials
Stand frame: The frame part to be welded to the apparatus wall must be suitable for this. The remaining parts of the
stand frame must at least correspond to the steel factory gate material no. 1.0038 according to DIN EN
10025.
Anchor bolts: minimum quality steel material no. 1.0038 or steel material no. 1.0570 according to DIN EN 10025.
Appendix A (informative)
References
DIN 8558-2
Design and execution of welded connections - tanks and apparatus made of steel for chemical plant construction
DIN EN 22553
Welded and soldered seams - Symbolic representation in drawings (ISO 2553: 1992); German version EN 22553:
1994