Copper-Fin Gas Boiler (Models CB 315-500) : CBA-Sub-08

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

COPPER-FIN®

COMMERCIAL GAS BOILER


Submittal Sheet CBA-Sub-08
COPPER-FIN GAS BOILER (MODELS CB 315-500)
Job Name: __________________________________ Model No. __________________________________
Location: __________________________________ Type Gas: __________________________________
Engineer: __________________________________ Equipment Tag(s):
BTU/hr
Agent/Wholesaler:______________________________ ______________________ INPUT: ______________
BTU/hr
Contractor: __________________________________ ______________________ OUTPUT: ______________

NOTES:

LEFT SIDE VIEW FRONT VIEW TOP VIEW

OUTLET INLET
4-1/2”
ELECTRICAL
CONNECTION

10-1/4”
A 18-3/4”

21-1/2”
17”

D
GAS CONNECTION
7” 6-1/4” 6-3/4” 7-1/4”
C B

Copper-Fin Boiler Dimensions & Specifications


Thermal Net AHRI
Model Input Efficiency Output Rating Gas Vent Ship.
Number MBH % MBH MBH A B C D Conn. Size Weight
CBN315 315 82.0 258 224 29-1/2” 32-1/4” 21-1/2” 16-1/4” 3/4” 8” 245
CBN360 360 82.0 295 257 29-1/2” 35-1/4” 21-1/2” 17-3/4” 1” 9” 255
CBN399 399 82.0 328 285 29-1/2” 44-1/2” 22” 22-1/4” 1” 10” 320
CBN500 500 82.0 410 357 34-1/2” 52-1/2” 22” 26-1/4” 1” 10” 345
Notes: Change ‘N’ to ‘L’ to denote L.P. gas models
No deration for L.P. models.
Water Connections are 2” NPT on 6-1/4” centers.
Performance data is based on manufacturer test results.
Standard Features Optional Equipment
• 84% A.F.U.E. Check the box by all options that apply:
• ASME Copper Finned Tube Heat Exchanger Adjustable High Limit w/ Manual Reset
• Gasketless Heat Exchanger Design Contacts on any Failure
• 82% Thermal Efficiency
Contacts for Air Louvers
• ASME Copper Finned Tube Heat Exchanger
• Gasketless Heat Exchanger Design Flow Switch
• Two Stage Intermittent Electronic Ignition Outdoor Air Reset Control
• 160 PSI Working Pressure Low Water Cut-Off
• Pump Relay Multi-Stack Frame
• Diagnostic Flash Codes Pump Delay/Freeze Protection
• Two Stage Solid State Temperature Control
MP2 Sequencer
• Two Stage Gas Valve with Built-In Manual Shut-Off
• Automatic Reset High Limit 3-Way Low Temperature Valve
• ASME Pressure Relief Valve
Firing Controls
• Temperature & Pressure Gauge
• Built-In Draft Diverter M9 - Two-Stage Intermittent Spark Ignition (Standard)
• CSA Design Certified for Alcove Installation M13 - GE GAP/FM/IRI
• CSA Design Certified for Installation on M7 - California Code
Combustible Floor
• Stainless Steel Burners
• Loch-Heat Ceramic Tile Combustion Chamber
• 24 Volt Control System
• 10 Year Limited Warranty on Heat Exchanger
(See warranty for details)

Lochinvar, LLC
300 Maddox Simpson Parkway
Lebanon, Tennessee 37090
P: 615.889.8900 / F: 615.547.1000
CERTIFIED
Lochinvar.com
4/19—Printed in U.S.A.