E1fw Metric PDF
E1fw Metric PDF
E1fw Metric PDF
E1FW
E1FW GLOBALLY APPROVED, EXPLOSIVE ATMOSPHERE
CABLE GLAND
CABLE GLAND MATERIAL Brass, Electroless Nickel Plated Brass, Aluminium cCSAus CERTIFICATE 1310517
SEAL MATERIAL CMP SOLO LSF Halogen Free Thermoset Elastomer Class II, Div 2, Groups E,F and G, Class III, Enclosure Type 4X,
CSAus CODE OF PROTECTION
Class I, Zone 1, AEx e II, AEx nR II
CABLE TYPE Single Wire Armour (SWA), Aluminium Wire Armour (AWA)
Class I, Div 2, Groups A,B,C and D, Class II, Div 2, Groups E,F and G, Class III, Enclosure
cCSA CODE OF PROTECTION
ARMOUR CLAMPING Detachable Armour Cone & AnyWay Universal Clamping Ring Type 4X, Ex d IIC, Ex e II, Ex nR II
SEALING TECHNIQUE CMP Inner Displacement Seal & Unique CMP ‘LRS’ TM Outer Load Retention Seal CAN/CSA-C22.2 No 0, 18, 25, 30, 94, 174, CAN/CSA-60079-0, 1, 7,
COMPLIANCE STANDARDS
ANSI/UL 514B Ed 5, ANSI/UL 50 Ed 11, ANSI/UL 2225 Ed 4, UL60079-0, 1, 7
SEALING AREA(S) Cable Inner Bedding & Outer Cable Sheath
EAC CERTIFICATE TC RU C-GB.AA87.B.00487 UkrSEPRO CЦ 19.0371X
* Mechanical & Electrical Classifications applied as per IEC 62444 & EN 62444 ** When CMP
installation accessories are used. Refer to www.cmp-products.com for further information. *** IP68 KCs KOSHA CERTIFICATE 14-GA4BO-0257X CCOE / PESO (INDIA) CERTIFICATE P444949
tested to a minimum depth of 30 metres for 12 hours, alternate depths / durations can be provided
upon request NEPSI CERTIFICATE GYJ18.1251X INMETRO APPROVAL TÜV 12.0618X
RETIE APPROVAL NUMBER 03866
MARINE APPROVALS LRS: 01/00172, DNV: TAE000000Y, ABS: 14-LD234401A-4-PDA, BV: 43180 A1 BV
ACROSS ACROSS
COMBINED ORDERING REFERENCE AVAILABLE ENTRY THREADS ‘C’ CABLE BEDDING DIAMETER ‘A’ OVERALL CABLE DIAMETER ‘B’ ARMOUR RANGE CABLE GLAND
FLATS ‘D’ CORNERS ‘D’ PROTRUSION
SHROUD WEIGHT
ORDERING THREAD LENGTH ‘F’
SIZE TYPE METRIC MIN MAX MIN MAX MIN MAX MAX MAX (kgs)
SUFFIX LENGTH ‘E’
20S16 E1FW 1RA5 M20 15.0 3.1 8.6 6.1 13.1 0.8 1.25 24.0 26.4 72.5 PVC04 0.16
20S E1FW 1RA5 M20 15.0 6.1 11.6 9.5 15.9 0.8 1.25 24.0 26.4 70.0 PVC04 0.15
20 E1FW 1RA5 M20 15.0 6.5 13.9 12.5 20.9 0.8 1.25 30.5 33.6 73.0 PVC06 0.21
25S E1FW 1RA5 M25 15.0 11.1 19.9 14.0 22.0 1.25 1.6 37.5 41.3 89.0 PVC09 0.33
25 E1FW 1RA5 M25 15.0 11.1 19.9 18.2 26.2 1.25 1.6 37.5 41.3 89.0 PVC09 0.33
32 E1FW 1RA5 M32 15.0 17.0 26.2 23.7 33.9 1.6 2.0 46.0 50.6 86.0 PVC11 0.43
40 E1FW 1RA5 M40 15.0 22.0 32.1 27.9 40.4 1.6 2.0 55.0 60.5 90.0 PVC15 0.62
50S E1FW 1RA5 M50 15.0 29.5 38.1 35.2 46.7 2.0 2.5 60.0 66.0 91.0 PVC18 0.75
50 E1FW 1RA5 M50 15.0 35.6 44.0 40.4 53.0 2.0 2.5 70.1 77.1 95.0 PVC21 0.95
63S E1FW 1RA5 M63 15.0 40.1 49.9 45.6 59.4 2.0 2.5 75.0 82.5 102.0 PVC23 1.34
63 E1FW 1RA5 M63 15.0 47.2 55.9 54.6 65.8 2.0 2.5 80.0 88.0 104.0 PVC25 1.34
75S E1FW 1RA5 M75 15.0 52.8 61.9 59.0 72.0 2.0 2.5 90.0 99.0 115.0 PVC28 2.11
75 E1FW 1RA5 M75 15.0 59.1 67.9 66.7 78.4 2.5 3.0 100.0 110.0 117.0 PVC30 2.42
90 E1FW 1RA5 M90 24.0 66.6 78.6 76.2 90.3 3.15 4.0 114.3 125.4 147.0 PVC32 4.21
100 E1FW 1RA5 M100 24.0 76.0 90.9 86.1 101.4 3.15 4.0 123.0 135.3 140.0 LSF33 4.45
115 E1FW 1RA5 M115 24.0 86.0 97.9 101.5 110.2 3.15 4.0 133.4 146.7 162.0 LSF34 6.19
130 E1FW 1RA5 M130 24.0 97.0 114.9 110.2 123.2 3.1.5 4.0 152.4 167.6 174.0 LSF35 8.34
*Note : For material options please add the following suffix to change the Ordering Reference ; Brass (no suffix required), Nickel Plated Brass “5”, Copper Free Aluminium “1”
For NPT options add the following digits to the material suffix; ½” = 31; ¾” = 32; 1” = 33; 1 ¼” = 34; 1 ½” = 35; 2” = 36; 2 ½” = 37; 3” = 38; 3 ½” = 39; 4” = 310 (Brass requires prefix ‘0’)
Examples: 32E1FW1RA534 = Nickel Plated Brass 1¼” NPT, 50SE1FW1RA035 = Brass 1½” NPT, 20E1FW1RA5 = Nickel Plated Brass M20
Dimensions are displayed in millimetres unless otherwise stated
Dimensions listed are for metric cable glands only. Dimensions for alternative threads may vary, please see supplementary technical data sheet.