PROJECT : CAMERA SUPPORTING STRUCTURE

CLIENT :
CONTRACTOR :
DESIGN CONSULTANT : SS CONSULTANTS & DESIGNERS

Design Calculation Report


FOR PTZ CAMERA SUPPORTING STRUCTURE
Doc No. :
Rev. No. :
DESIGN CALCULATION REPORT
Rev. Date : 20 March, 2020
Page : 2 of 7

Table of Contents
1. Introduction ............................................................................................................................................................................ 3
2. Design Philosophy ............................................................................................................................................................... 3
3. Design Loads .......................................................................................................................................................................... 3
3.1. Dead Loads .................................................................................................................................................................... 3
3.2. Live Loads ...................................................................................................................................................................... 3
3.3. Wind Loads ................................................................................................................................................................... 4
3.4. Seismic Loads (EQ) .................................................................................................................................................... 5
3.5. Description of the load cases considered in the staad model............................................................... 4
3.6. Load Combinations.................................................................................................................................................... 5
3.7. Element material Properties ................................................................................................................................ 6
4. Structural Model ................................................................................................................................................................... 6
5. Design Calculations ............................................................................................................................................................. 7
Staad Pro Input & Output File .......................................................................................................................................... 14
Doc No. :
Rev. No. :
DESIGN CALCULATION REPORT
Rev. Date : 20 March, 2020
Page : 3 of 7

1. Introduction

The aim of the present document is to explain and record the design calculations carried
out for a “Camera supporting structure”

This structure is used for supporting camera’s height of structure is 12m. A box (400x
500 size) is mounted at level of 4.5m. Weight of single camera is 2kg.

2. Design Philosophy

The analysis has been done using the structural analysis software STAAD Pro. A 3D
model of the structure has been prepared using the beam elements and analysis has
been carried out for different types of loads and their combinations which are explained
in the later part of this report.

Design of steel elements like columns & beam have been carried out by the software
STAAD Pro SS6 as according to IS 800:2007 (Limit State Design) which has been
explained in detail in the later part of this report.

3. Design Loads

3.1. Dead Loads (DL)

In general, the dead load includes the self-weight of structure, weight of roof sheeting,
Insulation pipes etc.

A. The self-weight (10% extra for nodes & connections) of the steel members of the
structure is considered in the Dead load case.
B. Weight of one camera considered is 2 kg and applied as nodal load in staad.

3.2. Live Loads (LL)

No live load is considered on the structure.

3.3. Seismic Loads (EQ)

The seismic loads have been calculated, according to IS-1893 (Part -1), following the next
considerations:

 Zone factor .24 for zone IV


Doc No. :
Rev. No. :
DESIGN CALCULATION REPORT
Rev. Date : 20 March, 2020
Page : 4 of 7

 Importance factor 1.0


 Response Reduction Factor 3
 Damping ratio 0.05

The seismic response of the structure has been calculated using the STAAD Pro
software, considering as mass source the dead loads of the structure, sheeting etc.

The nomenclature and description of the specific load patterns used in the calculation m
odel is defined in STAAD Pro.

3.4. Wind Loads (WL)

The wind loads have been calculated based on the parameters established for the stand
ard site conditions. For wind loads design code IS-875 (Part – 3) has been followed. The
following parameters have been considered for wind load calculation:

 Basic Design Wind Speed of 47 m/s has been considered as per IS875: Part3.
 Terrain Category: 1
 Probability factor K1=1
 Terrain factor K2=1.0
 Topographical factor K3=1.0
 Wind directionality factor Kd=1
 Area Averaging Factor Ka=1

From the above parameters the design wind speed comes out to be 47 m/s and wind pr
essure comes out to be 1.325 KN/m2. Using area averaging factor Ka=1 and wind directi
onality factor Kd=1 design wind pressure becomes 1.325 KN/m^2. The rest of
parameters, such as the roughness factor, external / internal pressure, net pressure, dra
g and force coefficients, have been taken from the code and applied subsequently as
Uniformly Distributed Load.
The pressure coefficients has been worked out from Table 31 of IS 875 part 3 for single f
rame sections and these are 0.7 for column member (DVs>6) & 1.2 for cantilever part (D
Vd<6) . Slope. The subsequent loads have been applied in model.
Doc No. :
Rev. No. :
DESIGN CALCULATION REPORT
Rev. Date : 20 March, 2020
Page : 5 of 7

3.5. Description of the load cases considered in the staad model

A load case defines how loads are to be applied to the structure, and how the structural
response is to be calculated. The nomenclature and description of the specific load cases
used in the calculation model is as follows:

Table: Load Case Definition


S.
Nomenclature Description
No.
1 DL Self-weight of Structure. Sheeting
2 EQX+ Seismic Response for motion direction +X
3 EQZ+ Seismic Response for motion direction +Z
4 WL+X (+Cpe) Wind Blowing towards (+X) direction with positive Internal Pressure
5 WL+Z (+Cpe) Wind Blowing towards (+Z) direction with positive Internal Pressure

3.6. Load Combinations

The program design in STAAD. Pro is based on a set of loading combination. The load co
mbinations are made according to IS 800:2007and IS875: Part 5 for Limit State design c
onditions. In total there are 29 load combinations formed for limit state condition each i
n accordance with table below:
Doc No. :
Rev. No. :
DESIGN CALCULATION REPORT
Rev. Date : 20 March, 2020
Page : 6 of 7

3.7. Element material Properties

The material properties for the structural steel are as follows:

 Structural Steel, modulus of stability, Es : 200000 MPa


 Structural Steel Yield strength : 250 MPa
 Structural Steel Ultimate strength : 410 MPa

4. Structural Model

The structure has been modeled in 3-dimensions for structural analysis, in which
mathematical model for the real structure is modeled. The same is presented below.

Figure 1 : Overall View


Doc No. :
Rev. No. :
DESIGN CALCULATION REPORT
Rev. Date : 20 March, 2020
Page : 7 of 7

5. Design Calculations

 Please refer Annexure –A for Staad Input & Output File for “Camera
supporting structure”
 Please refer Annexure –B for Foundation design for “Camera supporting
structure”

6. Result & Discussions

The 3D models have been checked for stress and are well within the allowable limits.
For Strength check refers annexure-A. Refer Annexure – B For Foundation design check.
ANNEXURE - A
Saturday, July 11, 2020, 06:54 PM
PAGE NO. 1

****************************************************
* *
* STAAD.Pro V8i SELECTseries6 *
* Version 20.07.11.33 *
* Proprietary Program of *
* Bentley Systems, Inc. *
* Date= JUL 11, 2020 *
* Time= 18:24:21 *
* *
* USER ID: *
****************************************************

1. STAAD SPACE
INPUT FILE: D:\E DRIVE\work\VAAN\Chitradurga - Davanagere\VIDS POLE\Staad\CAMERA-12M STRAIGHT POLE.STD
2. START JOB INFORMATION
3. ENGINEER DATE 10-MAY-19
4. END JOB INFORMATION
5. INPUT WIDTH 79
6. UNIT METER KN
7. JOINT COORDINATES
8. 1 0 -1 0; 2 0 11 0; 5 0 -2.8 0
9. MEMBER INCIDENCES
10. 1 1 2; 5 1 5
11. DEFINE MATERIAL START
12. ISOTROPIC STEEL
13. E 2.05E+008
14. POISSON 0.3
15. DENSITY 76.8195
16. ALPHA 1.2E-005
17. DAMP 0.03
18. TYPE STEEL
19. STRENGTH FY 253200 FU 407800 RY 1.5 RT 1.2
20. ISOTROPIC CONCRETE
21. E 2.17185E+007
22. POISSON 0.17
23. DENSITY 23.5616
24. ALPHA 1E-005
25. DAMP 0.05
26. TYPE CONCRETE
27. STRENGTH FCU 27579
28. END DEFINE MATERIAL
29. MEMBER PROPERTY INDIAN
30. 5 PRIS YD 0.75 ZD 0.75
31. MEMBER PROPERTY
32. 1 PRIS OCT STA 0.2 END 0.1 THI 0.004
33. CONSTANTS
34. MATERIAL STEEL MEMB 1
35. MATERIAL CONCRETE MEMB 5
36. SUPPORTS
37. 5 FIXED
38. DEFINE 1893 LOAD

D:\E DRIVE\work\VAAN\Chitradurga - Davanagere\VIDS POLE\Staad\CAMERA-12M STRAIGHT POLE.anl Page 1 of 15


Saturday, July 11, 2020, 06:54 PM
STAAD SPACE -- PAGE NO. 2

39. ZONE 0.16 RF 3 I 1 SS 1 DM 0.05


40. JOINT WEIGHT
41. 2 WEIGHT 0.02
42. SELFWEIGHT 1.1
43. LOAD 1 LOADTYPE SEISMIC TITLE S.L. X+
44. 1893 LOAD X 1
45. LOAD 2 LOADTYPE SEISMIC TITLE S.L. Z
46. 1893 LOAD Z 1
47. LOAD 3 LOADTYPE DEAD TITLE D.L.
48. SELFWEIGHT Y -1.1 LIST ALL
49. SELFWEIGHT Y -1.1 LIST 1
50. JOINT LOAD
51. 2 FY -0.02
52. LOAD 4 LOADTYPE WIND TITLE W.L. X
53. MEMBER LOAD
54. 1 UNI GX 0.103
55. LOAD 5 LOADTYPE WIND TITLE W.L. Z
56. MEMBER LOAD
57. 1 UNI GZ 0.103
58. LOAD COMB 6 GENERATED INDIAN CODE GENRAL_STRUCTURES 1
59. 3 1.5
60. LOAD COMB 7 GENERATED INDIAN CODE GENRAL_STRUCTURES 2
61. 3 1.2 4 1.2
62. LOAD COMB 8 GENERATED INDIAN CODE GENRAL_STRUCTURES 3
63. 3 1.2 5 1.2
64. LOAD COMB 9 GENERATED INDIAN CODE GENRAL_STRUCTURES 4
65. 3 1.2 4 -1.2
66. LOAD COMB 10 GENERATED INDIAN CODE GENRAL_STRUCTURES 5
67. 3 1.2 5 -1.2
68. LOAD COMB 11 GENERATED INDIAN CODE GENRAL_STRUCTURES 6
69. 3 1.2 1 1.2
70. LOAD COMB 12 GENERATED INDIAN CODE GENRAL_STRUCTURES 7
71. 3 1.2 2 1.2
72. LOAD COMB 13 GENERATED INDIAN CODE GENRAL_STRUCTURES 8
73. 3 1.2 1 -1.2
74. LOAD COMB 14 GENERATED INDIAN CODE GENRAL_STRUCTURES 9
75. 3 1.2 2 -1.2
76. LOAD COMB 15 GENERATED INDIAN CODE GENRAL_STRUCTURES 10
77. 3 1.5 4 1.5
78. LOAD COMB 16 GENERATED INDIAN CODE GENRAL_STRUCTURES 11
79. 3 1.5 5 1.5
80. LOAD COMB 17 GENERATED INDIAN CODE GENRAL_STRUCTURES 12
81. 3 1.5 4 -1.5
82. LOAD COMB 18 GENERATED INDIAN CODE GENRAL_STRUCTURES 13
83. 3 1.5 5 -1.5
84. LOAD COMB 19 GENERATED INDIAN CODE GENRAL_STRUCTURES 14
85. 3 1.5 1 1.5
86. LOAD COMB 20 GENERATED INDIAN CODE GENRAL_STRUCTURES 15
87. 3 1.5 2 1.5
88. LOAD COMB 21 GENERATED INDIAN CODE GENRAL_STRUCTURES 16

D:\E DRIVE\work\VAAN\Chitradurga - Davanagere\VIDS POLE\Staad\CAMERA-12M STRAIGHT POLE.anl Page 2 of 15


Saturday, July 11, 2020, 06:54 PM
STAAD SPACE -- PAGE NO. 3

89. 3 1.5 1 -1.5


90. LOAD COMB 22 GENERATED INDIAN CODE GENRAL_STRUCTURES 17
91. 3 1.5 2 -1.5
92. LOAD COMB 23 GENERATED INDIAN CODE GENRAL_STRUCTURES 18
93. 3 0.9 1 1.5
94. LOAD COMB 24 GENERATED INDIAN CODE GENRAL_STRUCTURES 19
95. 3 0.9 2 1.5
96. LOAD COMB 25 GENERATED INDIAN CODE GENRAL_STRUCTURES 20
97. 3 0.9 1 -1.5
98. LOAD COMB 26 GENERATED INDIAN CODE GENRAL_STRUCTURES 21
99. 3 0.9 2 -1.5
100. PERFORM ANALYSIS PRINT ALL

P R O B L E M S T A T I S T I C S
-----------------------------------

NUMBER OF JOINTS 3 NUMBER OF MEMBERS 2


NUMBER OF PLATES 0 NUMBER OF SOLIDS 0
NUMBER OF SURFACES 0 NUMBER OF SUPPORTS 1

SOLVER USED IS THE OUT-OF-CORE BASIC SOLVER

ORIGINAL/FINAL BAND-WIDTH= 2/ 2/ 12 DOF


TOTAL PRIMARY LOAD CASES = 5, TOTAL DEGREES OF FREEDOM = 12
TOTAL LOAD COMBINATION CASES = 21 SO FAR.
SIZE OF STIFFNESS MATRIX = 1 DOUBLE KILO-WORDS
REQRD/AVAIL. DISK SPACE = 12.0/ 112261.8 MB

D:\E DRIVE\work\VAAN\Chitradurga - Davanagere\VIDS POLE\Staad\CAMERA-12M STRAIGHT POLE.anl Page 3 of 15


Saturday, July 11, 2020, 06:54 PM
STAAD SPACE -- PAGE NO. 4

LOADING 1 LOADTYPE SEISMIC TITLE S.L. X+


-----------

LOADING 2 LOADTYPE SEISMIC TITLE S.L. Z


-----------

LOADING 3 LOADTYPE DEAD TITLE D.L.


-----------

SELFWEIGHT Y -1.100

ACTUAL WEIGHT OF THE STRUCTURE = 25.643 KN

SELFWEIGHT Y -1.100

ACTUAL WEIGHT OF THE STRUCTURE = 1.787 KN

JOINT LOAD - UNIT KN METE

JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z

2 0.00 -0.02 0.00 0.00 0.00 0.00

*WARNING- APPLIED SELFWEIGHT IS MORE THAN TOTAL WEIGHT OF ALL


STRUCTURAL ELEMENTS IN LOAD CASE 3 ALONG Y.
THIS COULD BE DUE TO SELFWEIGHT APPLIED TO SPECIFIC
LIST OF MEMBERS/PLATES/SOLIDS/SURFACES.
TOTAL UNFACTORED WEIGHT OF THE STRUCTURE = 25.643 KN
TOTAL UNFACTORED WEIGHT OF THE STRUCTURE APPLIED = 27.431 KN

LOADING 4 LOADTYPE WIND TITLE W.L. X


-----------

MEMBER LOAD - UNIT KN METE

MEMBER UDL L1 L2 CON L LIN1 LIN2

1 0.1030 GX 0.00 12.00

LOADING 5 LOADTYPE WIND TITLE W.L. Z


-----------

MEMBER LOAD - UNIT KN METE

MEMBER UDL L1 L2 CON L LIN1 LIN2

D:\E DRIVE\work\VAAN\Chitradurga - Davanagere\VIDS POLE\Staad\CAMERA-12M STRAIGHT POLE.anl Page 4 of 15


Saturday, July 11, 2020, 06:54 PM
STAAD SPACE -- PAGE NO. 5

1 0.1030 GZ 0.00 12.00

**WARNING: IF THIS UBC/IBC ANALYSIS HAS TENSION/COMPRESSION


OR REPEAT LOAD OR RE-ANALYSIS OR SELECT OPTIMIZE, THEN EACH
UBC/IBC CASE SHOULD BE FOLLOWED BY PERFORM ANALYSIS CHANGE.

*********************************************************
* *
* TIME PERIOD FOR X 1893 LOADING = 1.18234 SEC *
* SA/G PER 1893= 0.846, LOAD FACTOR= 1.000 *
* VB PER 1893= 0.0226 X 28.23= 0.64 KN *
* *
*********************************************************

*********************************************************
* *
* TIME PERIOD FOR Z 1893 LOADING = 1.18234 SEC *
* SA/G PER 1893= 0.846, LOAD FACTOR= 1.000 *
* VB PER 1893= 0.0226 X 28.23= 0.64 KN *
* *
*********************************************************

JOINT LATERAL TORSIONAL LOAD - 1


LOAD (KN ) MOMENT (KN -METE) FACTOR - 1.000
----- ------- ---------

1 FX 0.123 MY 0.000
----------- -----------
TOTAL = 0.123 0.000 AT LEVEL -1.000 METE
VB PER 1893 = 0.637 KN

2 FX 0.514 MY 0.000
----------- -----------
TOTAL = 0.514 0.000 AT LEVEL 11.000 METE
VB PER 1893 = 0.637 KN

JOINT LATERAL TORSIONAL LOAD - 2


LOAD (KN ) MOMENT (KN -METE) FACTOR - 1.000
----- ------- ---------

1 FZ 0.123 MY 0.000
----------- -----------
TOTAL = 0.123 0.000 AT LEVEL -1.000 METE
VB PER 1893 = 0.637 KN

2 FZ 0.514 MY 0.000
----------- -----------
TOTAL = 0.514 0.000 AT LEVEL 11.000 METE
VB PER 1893 = 0.637 KN

D:\E DRIVE\work\VAAN\Chitradurga - Davanagere\VIDS POLE\Staad\CAMERA-12M STRAIGHT POLE.anl Page 5 of 15


Saturday, July 11, 2020, 06:54 PM
STAAD SPACE -- PAGE NO. 6

FOR LOADING - 1
APPLIED JOINT EQUIVALENT LOADS
JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z
1 1.22904E-01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
2 5.13751E-01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00

STATIC LOAD/REACTION/EQUILIBRIUM SUMMARY FOR CASE NO. 1


LOADTYPE SEISMIC TITLE S.L. X+

CENTER OF FORCE BASED ON X FORCES ONLY (METE).


(FORCES IN NON-GLOBAL DIRECTIONS WILL INVALIDATE RESULTS)

X = 0.000000000E+00
Y = 0.868344628E+01
Z = 0.000000000E+00

***TOTAL APPLIED LOAD ( KN METE ) SUMMARY (LOADING 1 )


SUMMATION FORCE-X = 0.64
SUMMATION FORCE-Y = 0.00
SUMMATION FORCE-Z = 0.00

SUMMATION OF MOMENTS AROUND THE ORIGIN-


MX= 0.00 MY= 0.00 MZ= -5.53

***TOTAL REACTION LOAD( KN METE ) SUMMARY (LOADING 1 )


SUMMATION FORCE-X = -0.64
SUMMATION FORCE-Y = 0.00
SUMMATION FORCE-Z = 0.00

SUMMATION OF MOMENTS AROUND THE ORIGIN-


MX= 0.00 MY= 0.00 MZ= 5.53

MAXIMUM DISPLACEMENTS ( CM /RADIANS) (LOADING 1)


MAXIMUMS AT NODE
X = 1.78250E+01 2
Y = 0.00000E+00 0
Z = 0.00000E+00 0
RX= 0.00000E+00 0
RY= 0.00000E+00 0
RZ= -2.89469E-02 2

EXTERNAL AND INTERNAL JOINT LOAD SUMMARY ( KN METE )-

JT EXT FX/ EXT FY/ EXT FZ/ EXT MX/ EXT MY/ EXT MZ/
INT FX INT FY INT FZ INT MX INT MY INT MZ

SUPPORT=1
5 0.00 0.00 0.00 0.00 0.00 0.00
0.64 0.00 0.00 0.00 0.00 -7.31 111111

FOR LOADING - 2

D:\E DRIVE\work\VAAN\Chitradurga - Davanagere\VIDS POLE\Staad\CAMERA-12M STRAIGHT POLE.anl Page 6 of 15


Saturday, July 11, 2020, 06:54 PM
STAAD SPACE -- PAGE NO. 7

APPLIED JOINT EQUIVALENT LOADS


JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z
1 0.00000E+00 0.00000E+00 1.22904E-01 0.00000E+00 0.00000E+00 0.00000E+00
2 0.00000E+00 0.00000E+00 5.13751E-01 0.00000E+00 0.00000E+00 0.00000E+00

STATIC LOAD/REACTION/EQUILIBRIUM SUMMARY FOR CASE NO. 2


LOADTYPE SEISMIC TITLE S.L. Z

CENTER OF FORCE BASED ON Z FORCES ONLY (METE).


(FORCES IN NON-GLOBAL DIRECTIONS WILL INVALIDATE RESULTS)

X = 0.000000000E+00
Y = 0.868344628E+01
Z = 0.000000000E+00

***TOTAL APPLIED LOAD ( KN METE ) SUMMARY (LOADING 2 )


SUMMATION FORCE-X = 0.00
SUMMATION FORCE-Y = 0.00
SUMMATION FORCE-Z = 0.64

SUMMATION OF MOMENTS AROUND THE ORIGIN-


MX= 5.53 MY= 0.00 MZ= 0.00

***TOTAL REACTION LOAD( KN METE ) SUMMARY (LOADING 2 )


SUMMATION FORCE-X = 0.00
SUMMATION FORCE-Y = 0.00
SUMMATION FORCE-Z = -0.64

SUMMATION OF MOMENTS AROUND THE ORIGIN-


MX= -5.53 MY= 0.00 MZ= 0.00

MAXIMUM DISPLACEMENTS ( CM /RADIANS) (LOADING 2)


MAXIMUMS AT NODE
X = 0.00000E+00 0
Y = 0.00000E+00 0
Z = 1.78250E+01 2
RX= 2.89469E-02 2
RY= 0.00000E+00 0
RZ= 0.00000E+00 0

EXTERNAL AND INTERNAL JOINT LOAD SUMMARY ( KN METE )-

JT EXT FX/ EXT FY/ EXT FZ/ EXT MX/ EXT MY/ EXT MZ/
INT FX INT FY INT FZ INT MX INT MY INT MZ

SUPPORT=1
5 0.00 0.00 0.00 0.00 0.00 0.00
0.00 0.00 0.64 7.31 0.00 0.00 111111

FOR LOADING - 3
APPLIED JOINT EQUIVALENT LOADS
JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z

D:\E DRIVE\work\VAAN\Chitradurga - Davanagere\VIDS POLE\Staad\CAMERA-12M STRAIGHT POLE.anl Page 7 of 15


Saturday, July 11, 2020, 06:54 PM
STAAD SPACE -- PAGE NO. 8

APPLIED JOINT EQUIVALENT LOADS


JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z
1 0.00000E+00-1.55395E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
2 0.00000E+00-1.53344E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
5 0.00000E+00-1.31209E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00

STATIC LOAD/REACTION/EQUILIBRIUM SUMMARY FOR CASE NO. 3


LOADTYPE DEAD TITLE D.L.

CENTER OF FORCE BASED ON Y FORCES ONLY (METE).


(FORCES IN NON-GLOBAL DIRECTIONS WILL INVALIDATE RESULTS)

X = 0.000000000E+00
Y = -0.117275838E+01
Z = 0.000000000E+00

***TOTAL APPLIED LOAD ( KN METE ) SUMMARY (LOADING 3 )


SUMMATION FORCE-X = 0.00
SUMMATION FORCE-Y = -30.19
SUMMATION FORCE-Z = 0.00

SUMMATION OF MOMENTS AROUND THE ORIGIN-


MX= 0.0000000E+00 MY= 0.0000000E+00 MZ= 0.0000000E+00

***TOTAL REACTION LOAD( KN METE ) SUMMARY (LOADING 3 )


SUMMATION FORCE-X = 0.00
SUMMATION FORCE-Y = 30.19
SUMMATION FORCE-Z = 0.00

SUMMATION OF MOMENTS AROUND THE ORIGIN-


MX= 0.0000000E+00 MY= 0.0000000E+00 MZ= 0.0000000E+00

MAXIMUM DISPLACEMENTS ( CM /RADIANS) (LOADING 3)


MAXIMUMS AT NODE
X = 0.00000E+00 0
Y = -5.08522E-03 2
Z = 0.00000E+00 0
RX= 0.00000E+00 0
RY= 0.00000E+00 0
RZ= 0.00000E+00 0

EXTERNAL AND INTERNAL JOINT LOAD SUMMARY ( KN METE )-

JT EXT FX/ EXT FY/ EXT FZ/ EXT MX/ EXT MY/ EXT MZ/
INT FX INT FY INT FZ INT MX INT MY INT MZ

SUPPORT=1
5 0.00 -13.12 0.00 0.00 0.00 0.00
0.00 -17.07 0.00 0.00 0.00 0.00 111111

FOR LOADING - 4
APPLIED JOINT EQUIVALENT LOADS
JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z

D:\E DRIVE\work\VAAN\Chitradurga - Davanagere\VIDS POLE\Staad\CAMERA-12M STRAIGHT POLE.anl Page 8 of 15


Saturday, July 11, 2020, 06:54 PM
STAAD SPACE -- PAGE NO. 9

APPLIED JOINT EQUIVALENT LOADS


JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z
1 7.05376E-01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00-1.82180E+00
2 5.30624E-01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 7.73290E-01

STATIC LOAD/REACTION/EQUILIBRIUM SUMMARY FOR CASE NO. 4


LOADTYPE WIND TITLE W.L. X

CENTER OF FORCE BASED ON X FORCES ONLY (METE).


(FORCES IN NON-GLOBAL DIRECTIONS WILL INVALIDATE RESULTS)

X = 0.000000000E+00
Y = 0.499999987E+01
Z = 0.000000000E+00

***TOTAL APPLIED LOAD ( KN METE ) SUMMARY (LOADING 4 )


SUMMATION FORCE-X = 1.24
SUMMATION FORCE-Y = 0.00
SUMMATION FORCE-Z = 0.00

SUMMATION OF MOMENTS AROUND THE ORIGIN-


MX= 0.00 MY= 0.00 MZ= -6.18

***TOTAL REACTION LOAD( KN METE ) SUMMARY (LOADING 4 )


SUMMATION FORCE-X = -1.24
SUMMATION FORCE-Y = 0.00
SUMMATION FORCE-Z = 0.00

SUMMATION OF MOMENTS AROUND THE ORIGIN-


MX= 0.00 MY= 0.00 MZ= 6.18

MAXIMUM DISPLACEMENTS ( CM /RADIANS) (LOADING 4)


MAXIMUMS AT NODE
X = 1.40630E+01 2
Y = 0.00000E+00 0
Z = 0.00000E+00 0
RX= 0.00000E+00 0
RY= 0.00000E+00 0
RZ= -1.96908E-02 2

EXTERNAL AND INTERNAL JOINT LOAD SUMMARY ( KN METE )-

JT EXT FX/ EXT FY/ EXT FZ/ EXT MX/ EXT MY/ EXT MZ/
INT FX INT FY INT FZ INT MX INT MY INT MZ

SUPPORT=1
5 0.00 0.00 0.00 0.00 0.00 0.00
1.24 0.00 0.00 0.00 0.00 -9.64 111111

FOR LOADING - 5
APPLIED JOINT EQUIVALENT LOADS
JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z

D:\E DRIVE\work\VAAN\Chitradurga - Davanagere\VIDS POLE\Staad\CAMERA-12M STRAIGHT POLE.anl Page 9 of 15


Saturday, July 11, 2020, 06:54 PM
STAAD SPACE -- PAGE NO. 10

APPLIED JOINT EQUIVALENT LOADS


JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z
1 0.00000E+00 0.00000E+00 7.05376E-01 1.82180E+00 0.00000E+00 0.00000E+00
2 0.00000E+00 0.00000E+00 5.30624E-01-7.73290E-01 0.00000E+00 0.00000E+00

STATIC LOAD/REACTION/EQUILIBRIUM SUMMARY FOR CASE NO. 5


LOADTYPE WIND TITLE W.L. Z

CENTER OF FORCE BASED ON Z FORCES ONLY (METE).


(FORCES IN NON-GLOBAL DIRECTIONS WILL INVALIDATE RESULTS)

X = 0.000000000E+00
Y = 0.499999987E+01
Z = 0.000000000E+00

***TOTAL APPLIED LOAD ( KN METE ) SUMMARY (LOADING 5 )


SUMMATION FORCE-X = 0.00
SUMMATION FORCE-Y = 0.00
SUMMATION FORCE-Z = 1.24

SUMMATION OF MOMENTS AROUND THE ORIGIN-


MX= 6.18 MY= 0.00 MZ= 0.00

***TOTAL REACTION LOAD( KN METE ) SUMMARY (LOADING 5 )


SUMMATION FORCE-X = 0.00
SUMMATION FORCE-Y = 0.00
SUMMATION FORCE-Z = -1.24

SUMMATION OF MOMENTS AROUND THE ORIGIN-


MX= -6.18 MY= 0.00 MZ= 0.00

MAXIMUM DISPLACEMENTS ( CM /RADIANS) (LOADING 5)


MAXIMUMS AT NODE
X = 0.00000E+00 0
Y = 0.00000E+00 0
Z = 1.40630E+01 2
RX= 1.96908E-02 2
RY= 0.00000E+00 0
RZ= 0.00000E+00 0

EXTERNAL AND INTERNAL JOINT LOAD SUMMARY ( KN METE )-

JT EXT FX/ EXT FY/ EXT FZ/ EXT MX/ EXT MY/ EXT MZ/
INT FX INT FY INT FZ INT MX INT MY INT MZ

SUPPORT=1
5 0.00 0.00 0.00 0.00 0.00 0.00
0.00 0.00 1.24 9.64 0.00 0.00 111111

LOAD COMBINATION NO. 6


GENERATED INDIAN CODE GENRAL_STRUCTURES 1

D:\E DRIVE\work\VAAN\Chitradurga - Davanagere\VIDS POLE\Staad\CAMERA-12M STRAIGHT POLE.anl Page 10 of 15


Saturday, July 11, 2020, 06:54 PM
STAAD SPACE -- PAGE NO. 11

LOADING- 3.
FACTOR - 1.50

LOAD COMBINATION NO. 7


GENERATED INDIAN CODE GENRAL_STRUCTURES 2

LOADING- 3. 4.
FACTOR - 1.20 1.20

LOAD COMBINATION NO. 8


GENERATED INDIAN CODE GENRAL_STRUCTURES 3

LOADING- 3. 5.
FACTOR - 1.20 1.20

LOAD COMBINATION NO. 9


GENERATED INDIAN CODE GENRAL_STRUCTURES 4

LOADING- 3. 4.
FACTOR - 1.20 -1.20

LOAD COMBINATION NO. 10


GENERATED INDIAN CODE GENRAL_STRUCTURES 5

LOADING- 3. 5.
FACTOR - 1.20 -1.20

LOAD COMBINATION NO. 11


GENERATED INDIAN CODE GENRAL_STRUCTURES 6

LOADING- 3. 1.
FACTOR - 1.20 1.20

LOAD COMBINATION NO. 12


GENERATED INDIAN CODE GENRAL_STRUCTURES 7

LOADING- 3. 2.
FACTOR - 1.20 1.20

LOAD COMBINATION NO. 13


GENERATED INDIAN CODE GENRAL_STRUCTURES 8

LOADING- 3. 1.
FACTOR - 1.20 -1.20

LOAD COMBINATION NO. 14


GENERATED INDIAN CODE GENRAL_STRUCTURES 9

LOADING- 3. 2.
FACTOR - 1.20 -1.20

LOAD COMBINATION NO. 15


GENERATED INDIAN CODE GENRAL_STRUCTURES 10

D:\E DRIVE\work\VAAN\Chitradurga - Davanagere\VIDS POLE\Staad\CAMERA-12M STRAIGHT POLE.anl Page 11 of 15


Saturday, July 11, 2020, 06:54 PM
STAAD SPACE -- PAGE NO. 12

LOADING- 3. 4.
FACTOR - 1.50 1.50

LOAD COMBINATION NO. 16


GENERATED INDIAN CODE GENRAL_STRUCTURES 11

LOADING- 3. 5.
FACTOR - 1.50 1.50

LOAD COMBINATION NO. 17


GENERATED INDIAN CODE GENRAL_STRUCTURES 12

LOADING- 3. 4.
FACTOR - 1.50 -1.50

LOAD COMBINATION NO. 18


GENERATED INDIAN CODE GENRAL_STRUCTURES 13

LOADING- 3. 5.
FACTOR - 1.50 -1.50

LOAD COMBINATION NO. 19


GENERATED INDIAN CODE GENRAL_STRUCTURES 14

LOADING- 3. 1.
FACTOR - 1.50 1.50

LOAD COMBINATION NO. 20


GENERATED INDIAN CODE GENRAL_STRUCTURES 15

LOADING- 3. 2.
FACTOR - 1.50 1.50

LOAD COMBINATION NO. 21


GENERATED INDIAN CODE GENRAL_STRUCTURES 16

LOADING- 3. 1.
FACTOR - 1.50 -1.50

LOAD COMBINATION NO. 22


GENERATED INDIAN CODE GENRAL_STRUCTURES 17

LOADING- 3. 2.
FACTOR - 1.50 -1.50

LOAD COMBINATION NO. 23


GENERATED INDIAN CODE GENRAL_STRUCTURES 18

LOADING- 3. 1.
FACTOR - 0.90 1.50

LOAD COMBINATION NO. 24


GENERATED INDIAN CODE GENRAL_STRUCTURES 19

D:\E DRIVE\work\VAAN\Chitradurga - Davanagere\VIDS POLE\Staad\CAMERA-12M STRAIGHT POLE.anl Page 12 of 15


Saturday, July 11, 2020, 06:54 PM
STAAD SPACE -- PAGE NO. 13

LOADING- 3. 2.
FACTOR - 0.90 1.50

LOAD COMBINATION NO. 25


GENERATED INDIAN CODE GENRAL_STRUCTURES 20

LOADING- 3. 1.
FACTOR - 0.90 -1.50

LOAD COMBINATION NO. 26


GENERATED INDIAN CODE GENRAL_STRUCTURES 21

LOADING- 3. 2.
FACTOR - 0.90 -1.50

************ END OF DATA FROM INTERNAL STORAGE ************

101. PARAMETER 1
102. CODE IS800 LSD
103. START CONCRETE DESIGN
104. CODE INDIAN
105. FC 25000 MEMB 5
106. FYSEC 500000 MEMB 5
107. DESIGN COLUMN 5

D:\E DRIVE\work\VAAN\Chitradurga - Davanagere\VIDS POLE\Staad\CAMERA-12M STRAIGHT POLE.anl Page 13 of 15


Saturday, July 11, 2020, 06:54 PM
STAAD SPACE -- PAGE NO. 14

============================================================================

C O L U M N N O. 5 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe500 (Sec.)

LENGTH: 1800.0 mm CROSS SECTION: 750.0 mm X 750.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 4 END JOINT: 5 SHORT COLUMN

REQD. STEEL AREA : 73.13 Sq.mm.


REQD. CONCRETE AREA: 9140.63 Sq.mm.
MAIN REINFORCEMENT : Provide 12 - 12 dia. (0.24%, 1357.17 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 6350.06 Muz1 : 9.85 Muy1 : 9.85

INTERACTION RATIO: 0.98 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 15
END JOINT: 5 Puz : 6735.28 Muz : 184.58 Muy : 184.58 IR: 0.09
============================================================================

********************END OF COLUMN DESIGN RESULTS********************

108. END CONCRETE DESIGN


109. FINISH

D:\E DRIVE\work\VAAN\Chitradurga - Davanagere\VIDS POLE\Staad\CAMERA-12M STRAIGHT POLE.anl Page 14 of 15


Saturday, July 11, 2020, 06:54 PM
STAAD SPACE -- PAGE NO. 15

*********** END OF THE STAAD.Pro RUN ***********

**** DATE= JUL 11,2020 TIME= 18:24:23 ****

************************************************************
* For technical assistance on STAAD.Pro, please visit *
* http://selectservices.bentley.com/en-US/ *
* *
* Details about additional assistance from *
* Bentley and Partners can be found at program menu *
* Help->Technical Support *
* *
* Copyright (c) 1997-2015 Bentley Systems, Inc.
* http://www.bentley.com *
************************************************************

D:\E DRIVE\work\VAAN\Chitradurga - Davanagere\VIDS POLE\Staad\CAMERA-12M STRAIGHT POLE.anl Page 15 of 15


Design of foundation Annexure - B

Title Design of PTZ/VIDS Camera foundaion

Check for depth of foundation


Angle of friction of soil ( φ ) = 30.00 deg
Factored Moment (From Stadd ) = 14.46 KN-m
Factored Vertical Load (from Staad) = 45.29 KN
Total weight including self weight = 45.29 KN
Factor of safetry = 1.50
Unfactored Moment = 9.64 KNm
Density of soil = 18.00 Kn/m3
(As Per Rankine's Theory )
Coefficient of active earth pressur ka = 0.33
Coefficient of passive earth pressure Kp = 3.03
Breadth (b) = 0.75 m
Width (d) = 0.75 m
Depth of foundation Above F.R.L = 0.20 m
Depth of foundation Below F.R.L = 1.60 m
Required Depth of Foundation = 1.02 m
Provided Depth of Foundation = 1.60 m
Ok

Grade of Concrete = 25 N/mm2


φ = 30
cu = 0
δ = 22.5
πtanφ = 1.813799364
Nq = 18.4011
Nc = 30.13962779
Nϒ = 22.40248627
Co efficient of active earth pressure Ka = 0.297
Calculations of Pile Capacity of Pile

Dia of pile = 750 mm


Area of Pile at bottom = D^2/4
= 0.5625 m^2
Density of soil = 18 KN/m3
Length of Pile = 1.60 m
Type of Head = FREE HEAD
Critical depth of pile = 1.5 m
Over burden pressure at pile bottom(PD) = 27 KN/m2
Co efficient of friction between soil & pile = 0.5
Surface area of pile (As) = 1.2 m2

Capacity of pile due to skin friction (Qs) = 3.985894268 KN


Total capacity of pile (Qu) = 368.512378 KN
Factor of Safety (FOS) = 2.5
Safe capacity of Pile = 147.4049512 KN
Uplift Capacity of pile = 26.48589427 KN
FOS for vertical Load = 3.254619046
So Provide750X750 mm pile 1.6m deep